The Ontario Building Code | Loads for Dining Areas
4.1.5.6. Loads for Dining Areas
(1) The minimum specified live load listed in Table 4.1.5.3. for dining areas may be reduced to 2.4 kPa for areas in buildings that are being converted to dining areas, provided that the floor area does not exceed 100 m² and the dining area will not be used for other assembly purposes, including dancing.
In Plain Language
The minimum live load for dining areas can be reduced to 2.4 kilopascals for buildings being converted to dining use, recognizing that fixed-seating dining loads are generally lighter and more predictable than open assembly space.
This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.