The Ontario Building Code | Vertical Service Spaces for Dumbwaiters

3.5.3.2. Vertical service Spaces for Dumbwaiters

(1) A vertical service space containing a dumbwaiter shall be separated from all other portions of each adjacent storey by a fire separationhaving a fire-resistance rating conforming to Table 3.5.3.1. for the fire-resistance rating required by Subsection 3.2.2. for,

(a) the floor assembly above the storey,or

(b) the floor assembly below the storey, if there is no floor assembly above.

In Plain Language

A vertical service space containing a dumbwaiter needs the same kind of fire separation from adjacent storeys as an elevator hoistway, based on the same referenced fire-resistance rating table.

This is a plain-language summary of the 2012/2017 Ontario Building Code text above, for general understanding only and not a substitute for the Code. Always confirm current requirements against the 2024 edition (O.Reg. 163/24) or a qualified professional before construction.