The Ontario Building Code | Group F, Division 2, up to 4 Storeys, Increased Area

3.2.2.69. Group F, Division 2, up to 4 Storeys, Increased Area

(1) A building classified as Group F, Division 2 is permitted to conform to Sentence (2) provided,

(a) it is not more than 4 storeys in building height, and

(b) it has a building area not more than the value in Table 3.2.2.69.A. or Table 3.2.2.69.B.

(2) Except as permitted by Article 3.2.2.16., the buildingreferred to in Sentence (1) shall be of noncombustible construction, and,

(a) floor assemblies shall be fire separations with a fire-resistance rating not less than 1 h,

(b) mezzaninesshall have a fire-resistance rating not less than 1 h,

(c) if the buildingis not sprinklered, roof assemblies shall have a fire-resistance rating not less than 1 h, and

(d) loadbearingwalls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly.

Table 3.2.2.69.A.
Maximum Building Area, Group F, Division 2, up to 4 Storeys, Increased Area

Forming Part of Sentence 3.2.2.69.(1)

Item

Column 1

Column 2

Column 3

Column 4

No. of Storeys

Maximum Area, m2

Facing 1 Street

Facing 2 Streets

Facing 3 Streets

1.

1

6 000

7 500

9 000

2.

2

3 000

3 750

4 500

3.

3

2 000

2 500

3 000

4.

4

1 500

1 875

2 250

Table 3.2.2.69.B.
Maximum Building Area, Group F, Division 2, up to 4 Storeys, Increased Area, Sprinklered

Forming Part of Sentence 3.2.2.69.(1)

Item

Column 1

No. of Storeys

Column 2

Maximum Area, m2

1.

1

18 000

2.

2

9 000

3.

3

6 000

4.

4

4 500