The British Columbia Building Code | Index | Index

Index
British Columbia Building Code 2018 Index
Index
A
Abbreviations
acronyms, 1.3.2.1.
symbols and, 1.2.2.1.
terms and, 1.4.1.2.[A]
Acceptable solutions, 1.1.2.1., 1.2.1.1.[A]
Access
attics or roof spaces, 3.6.4.4., 9.19.2.1.
chimneys, 6.3.3.4.
crawl spaces, 3.6.4.6., 9.18.2.1., 9.18.4.1.
fire dampers, 3.1.8.10.
hatchways to roof, 9.19.2.1.
horizontal service spaces, 3.6.4.5., 9.18.2.1.,
9.18.4.1., 9.19.2.1.
HVAC equipment, 6.2.1.6., 9.33.4.4.
smoke dampers, 3.1.8.11.
Access to exits
capacity, 3.3.1.17., 9.9.3.
corridors in assembly occupancy, 3.3.2.6.
corridor width, 3.3.1.9.
dead-end corridors, 9.9.7.3.
definition, 1.4.1.2.[A]
dimensions, 9.9.3.
doors, 3.3.1.13., 3.3.2.7., 9.9.6., 9.9.7.4.
doors, sliding, 3.3.1.12.
doors, transparent, 3.3.1.19.
dwelling units, 9.9.9.
flame-spread rating, 9.10.21.6.
within floor areas, 3.3.1.3.
headroom clearance, 3.3.1.8., 9.9.3.4.
independent access to, 9.9.7.5.
lighting, 9.9.12.2.
podiums, terraces, platforms and contained open
spaces, 9.9.7.1.
residential occupancy, 3.3.4.4.
roofs, 3.3.1.3., 9.9.7.1.
service rooms, 9.9.7.5.
suites, 9.9.7.2.
transparent panels, 3.3.1.19.
travel distance, 9.9.7.6.
when exits are means of egress, 9.9.7.
Access for firefighting
access routes, 3.2.5.4., 3.2.5.5., 3.2.5.6.
basements, 3.2.5.2., 9.10.20.2.
and building size determination, 1.3.3.4.[A]
provisions, 9.10.20.
roof area, 3.2.5.3.
storeys below ground, 3.2.2.15.
storeys above grade, 3.2.5.1.
street frontages, 3.2.2.10.
Accessibility
floor surfaces, 3.8.3.2.
lavatories, 3.8.2.8., 3.8.3.15.
parking areas, 3.8.2.5.
path of travel (see Path of travel, accessible)
ramps, 3.8.3.5.
showers, 3.8.2.8., 3.8.3.16.
signs, 3.8.2.10., 3.8.3.9.
soap and towel dispensers, 3.8.3.15., 3.8.3.16.
spaces in seating areas, 3.8.2.3., 3.8.3.21.
telephone shelves, 3.8.2.11., 3.8.3.20.
universal washrooms, 3.8.2.8., 3.8.3.12.
urinals, 3.8.2.8., 3.8.3.14.
vestibules, 3.8.3.6.
washrooms, 3.8.2.8., 3.8.3.9., 3.8.3.11., 3.8.3.15.
water closets, 3.8.3.11., 3.8.3.13.
Access openings
construction barricades, 8.2.1.3.
HVAC systems, 6.8.1.1.
Access panels, 3.2.5.1., 9.10.20.1.
Access routes
design, 3.2.5.6.
location, 3.2.5.5., 9.10.20.3.
need for, 3.2.5.4.
self-service storage buildings, 3.9.2.3.
as streets, 3.2.2.10.
Adfreezing, 1.4.1.2.[A], 4.2.4.4.
Adhesives
ceramic wall tiles, 9.29.10.3.
ducts, 3.6.5.4., 9.33.6.4.
Administration of the Code, 2.2.[C]
Admixtures
concrete, 9.3.1.8.
mortar and grout, 9.20.3.2.
Aggregate
for built-up-roofing, 9.26.11.1., 9.26.11.4.
for concrete, 9.3.1.1., 9.3.1.4., 9.3.1.7.
for mortar, 5.9.1.1., 9.20.3.1., 9.20.3.2., 9.29.10.2.
for stucco, 9.28.2.2., 9.28.5.1.
______________________________________________________
[A] – Reference occurs in Division A of Volume 1.
[C] – Reference occurs in Division C of Volume 1.
All other references occur in Division B of Volume 1.
Index
Index British Columbia Building Code 2018
Air
circulation, 6.3.2.7., 9.33.6.7.
distribution, 9.33.6.11.
flow through and around insulation, 5.3.1.3.,
9.19.1.3., 9.25.2.3., 9.25.2.4.
leakage, 3.1.8.4., 5.1.1.1., 5.4.1.1., 5.9.3.4., 5.9.4.1.,
9.25.5.1.
leakage resistance, 5.4.1.1., 5.4.1.2., 9.13.4., 9.18.6.2.,
9.25.5.1.
makeup, 6.3.2.8., 9.32.3.8.
permeance, 5.4.1.2., 9.25.5.1.
tempering, 9.32.3.4., 9.32.3.8.
transfer, 5.1.1.1., 5.2.1.3.
Air barrier systems
airtightness, 5.4.1.1., 9.36.2.9., 9.36.2.10.
assemblies in contact with the ground, 9.13.4.,
9.25.3.6.
continuity, 5.4.1.2., 9.25.3.3., 9.36.2.9.
crawl space floors, 9.18.6.2.
definition, 1.4.1.2.[A]
deflections, 5.2.2.1.
energy efficiency, 9.36.2.9.
environmental loads, 5.1.4.1.
environmental separation, 5.1.1.1.
floors-on-ground, 9.18.6.2., 9.25.3.6.
housing and small buildings, 9.25.3.
installation, 9.23.2.2., 9.25.3.3.
material standards, 5.9.1.1., 9.18.6.2., 9.25.3.2.,
9.25.3.6.
properties, 9.25.3.1., 9.25.5.1.
properties of, 5.4.1.2., 9.25.3.2.
repair garages, 9.10.9.17.
requirement for, 9.25.3.1.
storage garages, 9.10.9.16.
Airborne sound rating, 3.3.4.6., 5.8.1.2., 9.11.
Air-conditioning systems and equipment
access, 6.2.1.6., 6.8.1.1., 9.33.4.4.
cleaning, 6.2.1.6., 9.33.4.4.
continuity of insulation, 9.36.3.5.
cooling units, 6.6.1.1.
design, 6.2.1., 9.33.1.1., 9.33.3.2., 9.33.4.1., 9.33.5.3.
energy efficiency, 9.36.
fire safety characteristics, 6.9.1.1., 9.33.6.
installation, 6.2.1., 6.6.1.1., 9.32.3.2., 9.33.1.1.,
9.33.4., 9.33.5.2., 9.33.9.1.
installation standards, 6.2.1.5., 9.33.5.2., 9.33.5.3.,
9.33.6.7.
performance requirements, 9.36.3.10.
protection from freezing, 6.2.1.6., 9.33.4.5.
structural movement, 4.1.8.18., 6.2.1.4., 9.33.4.7.
system pressure, 6.2.1.3., 9.33.4.6.
temperature controls, 9.36.3.6.
Air duct systems
application of Code, 6.3.2.1.
clearance of ducts and plenums, 6.3.2.6.
connections, 6.3.2.4.
drain pans, 6.3.2.2.
duct coverings and linings, 6.3.2.5.
interconnection, 6.3.2.7.
makeup air, 6.3.2.8.
materials, 6.3.2.3.
supply, return, intake and exhaust air openings,
6.3.2.9.
Air filters, 6.8.1.3., 9.33.6.14.
Air intakes
area, 9.32.3.13.
connection, 9.33.6.6.
grilles, 6.3.2.9., 9.33.6.10.
labeling, 9.32.3.13.
location, 6.3.2.9., 9.32.3.13., 9.33.6.10., 9.33.6.12.
protection, 6.3.2.9., 9.32.3.13., 9.33.6.10.
Air outlets
area, 9.32.3.13.
capacity, 9.33.6.11.
diffusers, 9.33.6.10., 9.33.6.11.
grilles, 6.3.2.9., 9.32.3.13., 9.33.6.10.
labeling, 9.32.3.13.
location, 6.3.2.9., 9.32.3.13., 9.33.6.10., 9.33.6.11.
protection, 6.3.2.9., 9.32.3.13., 9.33.6.10.
warm air heating, 9.33.6.10., 9.33.6.11.
Air quality, emergency power supply, 3.2.7.9.
Air-supported structures
clearance to flammable material, 3.1.6.4.
clearance to other structures, 3.1.6.3.
definition, 1.4.1.2.[A]
electrical systems, 3.1.6.7.
emergency air supply, 3.1.6.6.
fire protection, 9.10.1.3.
fire safety restrictions, 3.1.6.2.
flame resistance, 3.1.6.5.
means of egress, 3.1.6.1.
roof coverings, 3.1.15.2.
structural design basis, 4.4.1.1.
Airtightness
building envelope, 9.36.2.9., 9.36.2.10.
material standards, 5.9.1.1.
requirement for, 5.4.1.1.
windows, doors and skylights, 5.9.2.3., 9.7.4.
Index
British Columbia Building Code 2018 Index
Air washers, 6.3.2.16.
Aisles
with fixed seats, 3.3.2.5.
within floor areas, 3.3.1.10.
leading to exits, 3.4.2.5.
minimum clear width, 3.3.2.1.
outdoor places of assembly, 3.3.2.11.
with steps, handrails for, 3.3.2.10.
width, 3.4.3.2.
Alarm signal
audibility, 3.2.4.17., 3.2.4.18.
definition, 1.4.1.2.[A]
design, 3.2.4.4.
high buildings, 3.2.6.7.
silencing, 3.2.4.6.
system monitoring, 3.2.4.15.
Alert signal
audibility, 3.2.4.17., 3.2.4.18.
definition, 1.4.1.2.[A]
design, 3.2.4.4.
high buildings, 3.2.6.7.
system monitoring, 3.2.4.15.
Alterations to buildings, 1.1.1.1.[A], 1.4.1.2.[A]
Alternative materials, 1.2.2.1.[A]
Alternative solutions, 1.2.1.1.[A], 2.3.1.[C]
Aluminum
flashing, 9.20.13.1., 9.26.4.2., 9.27.3.7., 9.28.1.5.
nails, 9.26.2.3.
roofing, 9.26.13.1.
siding, 9.27.11.1.
structural design basis, 4.3.5.
Ammonium nitrate, 3.3.6.6.
Anchorage
anchor bolts, 9.20.11.6., 9.20.17.6.
columns, 9.23.6.2., 9.35.4.3.
concrete stairs, 9.8.10.2.
cornices, 9.20.11.5.
floors, 9.20.11.
foundations, 9.23.6., 9.35.4.3.
framing, 9.23.6.
horizontal force factor, 4.1.8.18.
lateral loads, 9.23.6.1.
masonry, 9.20.9., 9.20.11.
masonry walls to wood-frame construction,
9.20.11.3., 9.20.11.4.
roofs, 9.20.11., 9.20.17.6.
sills, 9.20.11.5.
small buildings, 9.23.6.3.
walls, 9.20.11., 9.23.3.4.
Anhydrous ammonia, storage, 3.3.6.3.
Annual energy consumption
building envelope, 9.36.5.6.
climatic data calculations, 9.36.5.5.
definition, 9.36.5.2.
HVAC systems, 9.36.5.7.
modeling, proposed house, 9.36.5.9. - 9.36.5.12.
modeling, reference house, 9.36.5.13. - 9.36.5.16.
performance compliance, 9.36.5.3.
performance compliance calculations, 9.36.5.4.
service water heating systems, 9.36.5.8.
Annunciators, fire alarm, 3.2.4.8., 3.2.4.9., 3.2.4.15.,
3.2.5.14., 3.2.7.10.
Antennas and antenna-supporting structures
earthquake loads and effects, 4.1.8.1.
wind loads, 4.1.7.11.
Apparent sound transmission class (ASTC)
calculation of, 5.8.1.4., 5.8.1.5.
definition, 1.4.1.2.[A]
Appliances
(see also Heating appliances; Heating systems
and equipment; Heating, ventilating and
air-conditioning (HVAC) systems and
equipment)
in access to exit, 3.3.1.2.
air-conditioning, 6.2.1., 9.33.4.1., 9.33.5.2.
characteristics, 1.2.2.1.[A]
cooling, 6.2.1., 6.6.1.1., 9.33.4.1., 9.33.5.2., 9.33.9.1.
definition, 1.4.1.2.[A]
in exit, 3.4.4.4.
exterior, 3.6.1.5.
fuel-fired, 3.6.2.1., 9.10.10.4.
heating, 6.2.1.1., 9.33.4.1., 9.33.5.2.
location, 3.6.1.5., 6.3.2.17., 6.4.1.1., 9.10.10.4.
in means of egress, 9.9.5.7.
outdoor location, 6.2.1.6., 6.3.2.17., 6.4.1.2.
protection from freezing, 6.2.1.6., 9.33.4.5.
roof-top, 3.6.1.5., 3.6.2.1., 6.4.1.2., 9.10.1.3.
solid-fuel-burning, 3.6.2.1., 6.2.1.5., 9.33.5.3.
storage, 1.2.2.2.[A]
used, 1.2.2.3.[A]
ventilating, 6.2.1., 9.32.3.2.
Application of Building Code
divisions A, B, C, 1.3.[A]
factory-constructed buildings, 1.1.1.1.[A]
farm buildings, 1.1.1.1.[A]
new buildings, 1.1.1.1.[A]
objectives, 2.1.1.[A], 3.2.[A]
Index
Index British Columbia Building Code 2018
seasonally and intermittently occupied buildings,
9.1.1.1.
Arches
fire-resistance ratings, 9.10.8.3.
in storeys below ground, 3.2.2.15.
supporting floor above basement, 3.2.1.4.
supporting masonry over openings, 9.20.5.2.
supporting service room/space, 3.1.7.5.
Arch roofs, snow and rain loads, 4.1.6.10.
Areas of refuge, 3.3.3.6.
Areas and spaces
design, 9.5.
dimensions, 9.5.1.1.
Arena-type buildings
building classification, 3.1.2.3.
building height exceptions, 3.2.1.1.
roof assemblies, 3.2.2.17.
seating, 3.3.2.2.
Artesian groundwater, 1.4.1.2.[A], 4.2.5.5.
Asbestos in air distribution systems and equipment,
6.2.1.7., 9.33.4.8.
Assembly areas
loads on floor or roof, 4.1.5.3.
loads on tributary areas, 4.1.5.8.
sway forces and load, 4.1.5.10.
Assembly occupancy (Group A)
air-supported structure as, 3.1.6.6.
assistive listening devices, 3.8.2.9., 3.8.3.18.
building classification, 3.1.2.1.
corridors, 3.3.2.6.
definition, 1.4.1.2.[A]
doors, 3.3.2.7.
fire protection, 3.2.2.17., 3.2.2.20. - 3.2.2.35., 9.10.1.3.
fire safety within floor areas, 3.3.1., 3.3.2.1.
location of smoke/fire dampers, 3.1.8.7.
occupant load, 3.1.17.1.
signals to fire department, 3.2.4.7.
visual alarm signals, 3.2.4.19.
washrooms, 3.7.2.
wheelchair spaces, 3.8.2.3.
Assistive listening devices, 3.8.2.9., 3.8.3.18.
Atomizers, 6.3.2.16.
Attendant booths, 6.3.1.4.
Attics or roof spaces
access, 3.6.4.4., 9.19.2.
clearances, 9.19.1.3.
definition, 1.4.1.2.[A]
exterior wall enclosing, 3.2.3.3.
fire blocks, 3.1.11.1., 3.1.11.5., 9.10.16.1.
fire protection, 9.10.12.4.
foamed plastics in, 3.1.4.2., 9.10.17.10.
housing and small buildings, 9.19.
insulation, 9.25.2.4.
loads, 4.1.5.3., 9.4.2.4.
in noncombustible construction, 3.1.5.3.
service spaces, 3.6.1.1.
soffits protection, 3.2.3.16.
venting, 5.3.1.2., 6.3.1.2., 9.19.1.
Audible signal devices, 3.2.4.17., 3.2.4.18.
Auditoriums, 3.2.2.21., 3.2.2.22.
Authority having jurisdiction, 1.4.1.2.[A]
Automatic locking devices, 3.3.4.5.
Automatic sprinkler systems (see Sprinkler systems)
B
Backdraft prevention, 6.3.2.10., 9.32.3.13.
Backfill
(see also Fill)
excavations, 9.12.3.
material, 4.2.5.8., 9.12.3.3.
Backfilling
(see also Fill)
beneath concrete stairs, 9.8.10.3.
beneath floors on grade, 4.2.5.8.
beneath footings, 4.2.5.8.
beneath foundations, 4.2.5.8.
grading, 9.12.3.2.
placement, 4.2.5.8., 9.12.3.1.
review, 4.2.2.3.
Bacteria, minimizing growth of, 6.3.1.6., 6.3.2.15.
Balance stops, 9.33.6.9.
Balconies
as access to exit, 9.9.9.3.
concealed spaces in, 3.1.11.5.
doors and door hardware, 3.3.1.13.
earthquake load and effects, 4.1.8.1.
exception to travel limit, 9.9.9.1.
exterior, 3.2.2.11.
guards around, 3.3.1.18., 9.8.8.
horizontal exits, 3.4.6.10.
limiting distance, 3.2.3.6.
loads on floor or roof, 4.1.5.3., 4.1.5.4., 9.4.2.3.
occupant load, 3.1.17.1.
snow loads, 9.4.2.3.
sprinkler systems, 3.2.5.12.
wind loads, 4.1.7.5.
Banks, 3.4.6.17.
Index
British Columbia Building Code 2018 Index
Barricades, construction and demolition sites, 8.2.1.3.,
8.2.3.3.
Barrier-free (see Accessibility)
Barriers
across transparent panels, 3.3.1.19.
preventing exit obstruction, 3.4.6.11., 9.9.11.2.
Basements
access, 3.2.5.2., 9.10.20.2.
ceiling height, 9.5.3.1.
crawl spaces considered as, 3.2.2.9., 9.10.8.9.
definition, 1.4.1.2.[A]
exit signs, 3.4.5.2.
fire containment, 3.2.1.5.
fire protection, 3.2.2.15., 9.10.1.3.
fire-resistance of floor assemblies over, 3.2.1.4.
fire separations, 9.10.9.4., 9.10.9.14.
heating requirements, 9.33.3.1.
industrial occupancy (Group F), 3.3.5.3.
insulation, 9.25.2.2.
large or multi-storey, 9.10.1.3.
lighting, 9.34.2.3., 9.34.2.4.
residential occupancy (Group C), 3.2.2.47.
storage garages, 3.1.10.3., 3.2.1.2., 9.10.4.3.
supply outlets, 9.33.6.11.
Bathroom accessories, 3.7.2.3., 3.7.2.9., 3.8.3.8.,
3.8.3.11., 3.8.3.15., 3.8.3.17.
Bathrooms
(see also Washrooms)
ceiling height, 9.5.3.1.
doorways, 9.4.4.3.
flame-spread rating, 3.1.13.3.
Bathtubs, 3.7.2.9., 3.8.3.17., 9.6.1.4.
Beams
bearing, 9.23.8.1.
built-up, 9.23.4.2., 9.23.4.4., 9.23.8.3.
dimensions, 9.23.4.1.
glued-laminated, 9.23.4.1., 9.23.4.2., 9.23.4.4.
in heavy timber construction, 3.1.4.7.
lumber grade, 9.3.2.1.
preservative treatment, 9.23.2.2., 9.23.2.3.
ridge, 9.23.14.8.
spans, 9.23.4.1., 9.23.4.2., 9.23.4.4.
spans, maximum, 9.23.4.
steel, 9.23.4.3., 9.23.8.2.
supported on masonry or concrete, 9.10.9.9.,
9.15.5., 9.20.8.3., 9.20.8.4., 9.21.5.3., 9.23.2.2.,
9.23.2.3.
to support floors, 9.23.8.
wood, 9.23.4.2., 9.23.4.4.
Bearing surface, 1.4.1.2.[A]
Bedrooms
means of egress, 9.9.10.1.
mechanical ventilation, 9.32.2.3.
natural ventilation, 9.32.2.2.
windows, 9.9.10.1.
Bleachers
aisles, 3.3.2.5.
guards, 3.3.2.9.
inspection, 4.1.5.12.
load analysis, 4.1.5.12.
locking, 4.1.5.12.
seats, 3.3.2.5.
steps, 3.3.2.5., 3.3.2.12.
Blocking
cladding, 9.27.5.2.
cladding and interior finishing materials, 9.23.10.5.
doors, 9.7.5.2.
with handrails, 9.8.7.7.
joists, 9.23.9.3., 9.23.9.4., 9.23.14.9.
nailing, 9.23.3.4.
in noncombustible construction, 3.1.5.2.
rafters and joints, 9.23.14.7.
roof edges, 9.23.16.6., 9.23.16.7.
subflooring, 9.23.15.3.
walls, 9.23.9.8., 9.23.10.2.
Boarding and lodging houses, 9.10.9.14.
Boiler rooms, 3.6.2.2., 9.10.10.4.
Boilers
definition, 1.4.1.2.[A]
installation standard, 6.2.1.5.
performance requirements, 9.36.3.10.
Bonding
intersecting masonry walls, 9.20.11.2.
masonry, 9.20.9.
Book shelves, 3.3.2.13.
Braced wall bands, 1.4.1.2.[A], 9.23.13.4., 9.23.13.5.
Braced wall panels
anchorage, 9.23.6.1., 9.23.13.5.
definition, 1.4.1.2.[A]
fastening, 9.23.3.4., 9.23.3.5.
gypsum board, 9.29.5.9.
lateral loads, 9.23.13.5., 9.23.13.6.
plywood, 9.29.6.3.
and wall supports, 9.23.9.8.
Bracing, wood-frame walls, 9.23.13., 9.23.13.4.,
9.23.13.5.
Breeching, 1.4.1.2.[A]
Bridging floor joists, 9.23.9.4.
Index
Index British Columbia Building Code 2018
Builder (see Constructor)
Building area
assembly occupancy (Group A, Division 1),
3.2.2.20.
assembly occupancy (Group A, Division 2),
3.2.2.23.
assembly occupancy (Group A, Division 3),
3.2.2.29.
business and personal services occupancy (Group
D), 3.2.2.55.
care, treatment or detention occupancy (Group B
Division 1), 3.2.2.36., 3.2.2.37.
care, treatment or detention occupancy (Group B
Division 2), 3.2.2.38. - 3.2.2.41.
care, treatment or detention occupancy (Group B
Division 3), 3.2.2.42. - 3.2.2.46.
definition, 1.4.1.2.[A]
determination, 1.3.3.4.[A]
determination of fire safety requirements, 3.2.2.5.
high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.70.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.80.
medium-hazard industrial occupancy (Group F,
Division 2), 3.2.2.74.
mercantile occupancy (Group E), 3.2.2.64.
residential occupancy (Group C), 3.2.2.47.
self-service storage buildings, 3.9.2.1.
Building assemblies
effective thermal resistance, 9.36.2.6.
fire-resistance rating, 3.1.7.5.
off-site review, 2.2.7.5.[C]
replacement options, 9.36.2.11.
thermal resistance calculation, 9.36.2.4.
Building classification
by major occupancy, 3.1.2.1., 9.10.2.
for wind load calculations, 4.1.7.2.
Building, definition, 1.4.1.2.[A]
Building envelope
energy efficiency, 9.36.2.
energy performance calculations, 9.36.5.6.
energy performance modeling, 9.36.5.10., 9.36.5.14.
replacement options, 9.36.2.11.
thermal resistance calculation, 9.36.2.4.
Building height
access route design, 3.2.5.6.
assembly occupancy (Group A, Division 1),
3.2.2.20.
assembly occupancy (Group A, Division 2), 3.2.2.23.
assembly occupancy (Group A, Division 3),
3.2.2.29.
business and personal services occupancy (Group
D), 3.2.2.55., 3.2.2.57., 3.2.2.58.
care, treatment or detention occupancy (Group B
Division 1), 3.2.2.36., 3.2.2.37.
care, treatment or detention occupancy (Group B
Division 2), 3.2.2.38. - 3.2.2.41.
care, treatment or detention occupancy (Group B
Division 3), 3.2.2.42. - 3.2.2.46.
definition, 1.4.1.2.[A]
determination, 1.3.3.4.[A], 9.10.4.
determination of fire safety requirements, 3.2.2.5.
exceptions, 3.2.1.1.
garages as separate buildings, 9.10.4.3.
high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.70.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.80.
medium-hazard industrial occupancy (Group F,
Division 2), 3.2.2.74.
mercantile occupancy (Group E), 3.2.2.64.
mezzanines excluded, 9.10.4.1.
mezzanines included, 9.10.4.2.
residential occupancy (Group C), 3.2.2.47.,
3.2.2.50., 3.2.2.51.
roof-top enclosures excluded, 9.10.4.4.
Building services
accessible controls, 3.8.3.8.
emergency power supply, 3.2.7.9.
and fire alarm systems, 3.2.4.2.
and firewalls, 3.1.10.1.
penetrating fire separations and fire-rated
assemblies, 3.1.9.2., 9.10.9.6.
Building size determination
application of Code, 1.3.3.4.[A]
inclusions, 9.10.4.1.
relative to occupancy, 9.10.8.
Built-up roofing, 9.26.11.
Business and personal services occupancy (Group D)
classification, 3.1.2.1., 9.10.2.
definition, 1.4.1.2.[A]
emergency power for fire alarm systems, 3.2.7.8.
emergency power for lighting, 3.2.7.4.
exit stairs, 9.9.4.7.
exposing building face, 9.10.14.5.
fire access route design, 3.2.5.6.
fire alarm systems, 3.2.4.1., 9.10.18.
Index
British Columbia Building Code 2018 Index
fire protection, 3.2.2.55. - 3.2.2.63.
fire-resistance rating, 9.10.8.
fire safety within floor areas, 3.3.1.
flame-spread rating, 9.10.17.
occupant load, 3.1.17.1.
sprinkler systems, 3.2.5.12.
washrooms, 3.7.2.
C
Cabinetry, around cooktops, 9.10.22.3.
Cables
in air barrier systems, 9.36.2.10.
in combustible construction, 3.1.4.3.
elevator, 3.1.5.22.
in noncombustible construction, 3.1.5.21.
penetrating fire separations, 3.1.9.3.
in plenums, 3.6.4.3.
Caissons (see Pile foundations)
Calculations and analyses
heat, air and moisture transfer, 5.2.1.2., 5.2.1.3.
HVAC equipment and systems, 6.2.1.1., 9.33.4.1.
limit states design, 4.1.3.
snow, rain and ice load, 4.1.6.
structural, 2.2.4.5.[C], 4
wind load, 4.1.7., 5.2.1.3., 5.2.2.2.
Canopies
fabrics, 3.1.16.1.
for vertically separated openings, 3.2.3.17.
Capacity of exit, 3.4.3.2.
Carbon monoxide
alarms, 9.32.3.8., 9.32.3.9.
concentration, 6.3.1.4.
detectors, 6.3.1.4., 6.9.3.1., 9.32.3.8., 9.32.3.9.
Care, definition, 1.4.1.2.[A]
Care, treatment or detention occupancy (Group B)
building classification, 3.1.2.1.
definition, 1.4.1.2.[A]
door hold-open devices, 3.1.8.14.
doorway width, 3.3.3.4.
electromagnetic locks, 3.4.6.17.
emergency lighting, 3.2.7.3.
emergency power supply, 3.2.7.6.
evaporative cooling towers, 6.3.2.15.
fire alarm systems, 3.2.4.1., 3.2.4.18.
fire protection, 3.2.2.36. - 3.2.2.46.
fire safety within floor areas, 3.3.1., 3.3.3., 3.3.3.1.
location of smoke/fire dampers, 3.1.8.7.
occupant load, 3.1.17.1.
ramp slope maximum, 3.4.6.7.
as residential occupancy, 3.1.2.5.
self-closing door hardware, 3.1.8.13.
sleeping room exits, 3.4.1.6.
smoke alarms, 3.2.4.20.
smoke detectors, 3.2.4.11.
sprinkler systems, 3.2.2.19., 3.2.5.12.
visual alarm signals, 3.2.4.19.
Carpets, 3.1.13.1.
Carports
(see also Garages)
columns, 9.35.4.2., 9.35.4.3.
concrete for floors, 9.3.1.6.
for dwelling units, 9.35.
spatial separation from other buildings, 9.10.14.4.
walls, 9.35.4.1., 9.35.4.3.
Catch basins, 9.14.6.4.
Caulking
(see also Sealants)
for ceramic wall tile, 9.29.10.5.
door frames, 9.20.13.11.
material standards, 9.29.10.5.
in noncombustible construction, 3.1.5.2.
requirements, 9.27.4., 9.27.4.1.
sill plates, 9.23.7.2.
stucco, 9.28.1.5.
windows and frames, 9.7.6.2., 9.20.13.11.
Cavity walls
corbelling, 9.20.12.2.
definition, 1.4.1.2.[A]
flashing, 9.20.13.5., 9.20.13.6.
framing supported by, 9.20.8.2.
height and thickness, 9.20.6.2.
lateral support, 9.20.10.1.
mortar droppings, 9.20.13.10.
precipitation protection, 9.27.2.2.
tying, 9.20.9.4.
Ceiling membranes
fire-resistance rating, 3.6.4.3., 9.10.3.4.
fire stop flaps, 9.10.13.14.
openings in, 3.1.9.6., 9.10.5., 9.10.9.6., 9.10.9.7.
suspended, 9.10.3.4.
Ceiling panels, factory-assembled, 3.1.5.7.
Ceilings
air barrier systems, 9.25.3.
area, calculating, 9.36.2.3.
assembly used as plenum, 3.1.9.7.
in corridors, 3.1.13.6.
effective thermal resistance, 9.36.2.6.
Index
Index British Columbia Building Code 2018
fastened to floor joists, 9.23.9.4.
finish, 3.1.5.12., 9.29.
foamed plastics in, 9.10.17.10.
framing, 9.23.14.
framing around openings, 9.23.14.2.
height, 9.5.3.
joists, 9.23.14.1., 9.23.14.7.
thermal insulation, 9.25.1.1.
Cement, standards for, 9.3.1.2.
Central alarm and control facility, 3.2.4.22., 3.2.6.4.,
3.2.6.7.
Ceramic tile
as flooring, 9.30.6.
installation, 9.29.10.1.
as interior finish, 9.29.10.
subfloor, 9.23.15.5.
underlay, 9.23.15.5., 9.30.2.1., 9.30.2.2.
Chases, 9.20.7.
Children’s custodial homes, 3.1.2.5., 3.2.4.3., 9.10.2.2.
Chimneys
access ladders, 6.3.3.4.
airtightness, 9.36.2.10.
bracing, 9.21.4.5.
caps, 9.21.4.6.
cleanouts, 9.21.4.7.
clearances, 6.3.3.1., 9.21.5., 9.25.3.3.
concrete, 1.4.1.2.[A], 6.3.3.2., 9.21., 9.21.4.2.,
9.33.10.3.
construction, 9.21.4.
definition, 1.4.1.2.[A]
design of, 6.3.3.2., 9.20.2.3., 9.21., 9.33.10.3.
earthquake loads and effects, 4.1.8.1.
factory-built, 1.4.1.2.[A], 9.33.10.2.
fireplace, 9.21.2.4., 9.21.2.5.
flashing, 9.21.4.6., 9.21.4.10., 9.26.4.4., 9.26.4.6.,
9.26.4.8.
flues, 9.21.2., 9.21.4.4.
footings, 9.21.4.3.
fuel-fired appliances, 6.3.3.1., 9.33.10.1.
incinerators, 9.10.10.5., 9.21.2.1.
lateral stability, 9.21.4.5.
liners (see Liners, chimney)
masonry, 1.4.1.2.[A], 6.3.3.2., 9.21., 9.21.4.1.,
9.33.10.3.
metal, 6.3.3.3., 9.33.10.2.
saddles, 9.26.4.8.
sealing, 9.21.5.2.
venting equipment, 6.3.1.
walls, 9.21.1.2.
wall thickness, 9.21.4.8.
Chutes
linen, 3.6.3.3., 9.10.1.3.
refuse, 3.6.3.3., 9.10.1.3.
sprinklers, 3.6.3.3.
venting, 3.6.3.3.
Cladding
attachment, 9.27.5.
for braced wall panels, 9.23.13.6.
combustible, 9.10.14.5., 9.10.15.5.
in combustible construction, 3.1.4.8.
exposing building face, 3.2.3.7.
fastening to steel studs, 9.24.1.4.
housing and small buildings, 9.27.
installation, 5.6.1.2., 5.9.1.1., 9.27.2.4., 9.27.3.6.,
9.27.5.
interior, 3.1.13.1.
noncombustible, 3.1.4.8., 3.2.3.7., 3.2.3.9.
in noncombustible construction, 3.1.5.5.
protection against precipitation, 5.6.
requirement for, 5.6.1.1., 9.27.2.1.
sealing, 5.6.2.1., 9.27.3.6., 9.27.4.
on steel studs, 9.24.1.5.
support of, 9.20.5., 9.23.10.5., 9.24.3.4.
waterproofing, 9.27.4.
wind loads, 4.1.7.5., 4.1.7.6., 4.1.7.12.
Cladding, clay tile, 9.23.4.5.
Cladding, concrete
design, 9.20.6.6.
water absorption, 9.20.2.6.
weight, 9.20.2.6.
Cladding, decorative, 3.1.5.24.
Cladding, hardboard
clearances, 9.27.2.4., 9.27.9.5.
dimensions, 9.27.9.2.
housing and small buildings, 9.27.9.
installation, 9.27.2.4., 9.27.3.6., 9.27.5., 9.27.9.3.
material standards, 5.9.1.1., 9.27.9.1.
Cladding, lumber
dimensions, 9.27.6.2.
housing and small buildings, 9.27.6.
installation, 5.9.1.1., 9.27.2.4., 9.27.3.6., 9.27.5.
material standards, 5.9.1.1.
Cladding, masonry
bonding and tying, 9.20.9.
flashing, 9.20.13.
housing and small buildings, 9.20., 9.27.2.2.
installation, 5.6.1.2.
material standards, 5.9.1.1.
Index
British Columbia Building Code 2018 Index
mortar joints, 9.20.4.
support of, 9.20.5.
Cladding, metal
housing and small buildings, 9.27.11.
installation, 5.9.1.1., 9.27.3.6., 9.27.5.
material standards, 5.9.1.1., 9.27.11.1.
Cladding, OSB and waferboard
clearances, 9.27.2.4., 9.27.10.4.
dimensions, 9.27.10.2.
housing and small buildings, 9.27.10.
installation, 9.27.2.4., 9.27.3.6., 9.27.5., 9.27.10.3.,
9.27.10.4.
material standards, 5.9.1.1., 9.27.10.1.
Cladding, plywood
dimensions, 9.27.8.2.
housing and small buildings, 9.27.8.
installation, 9.27.2.4., 9.27.3.6., 9.27.5., 9.27.8.3.
material standards, 5.9.1.1., 9.27.8.1.
sealing, 5.6.2.1., 9.27.8.3., 9.27.8.4.
Cladding, stone, 9.20.6.6.
Cladding, vinyl
housing and small buildings, 9.27.12.
installation, 9.27.5., 9.27.12.2.
material standards, 5.9.1.1., 9.27.12.1.
Cladding, waferboard (see Cladding, OSB and
waferboard)
Cladding, wood shingles and shakes
grades, 9.27.7.1.
housing and small buildings, 9.27.7.
material standards, 5.9.1.1., 9.27.7.1.
Classification of buildings/building parts
by major occupancy, 3.1.2.1., 9.10.2.
for wind load calculations, 4.1.7.2.
Clearances
(see also Headroom clearance)
attic or roof spaces, 9.19.1.3.
chimneys, 6.3.3.1., 9.21.5., 9.25.3.3.
cladding above ground, 9.27.2.4.
cladding to roof, 9.27.2.4.
combustible framing, 9.22.9.3.
combustible material, 6.3.2.6., 9.22.9., 9.33.6.8.
cooktops, 9.10.22.1.
cooling towers, 6.3.2.15.
crawl spaces, 9.18.4.1.
door frames, 9.27.9.5., 9.27.10.4.
ducts, 6.3.2.6., 9.22.9.4., 9.33.6.8.
electric ranges, 9.10.22.1.
furnace plenums, 6.3.2.6., 9.33.6.8.
furnaces, 6.2.1.5., 9.33.5.2.
gas-fired ranges, 9.10.22.1.
gas vents, 9.25.3.3.
above ground, 9.15.4.6., 9.27.2.4.
handrails, 9.8.7.5.
hardboard siding, 9.27.9.5., 9.27.10.4.
heating and air-conditioning equipment, 6.2.1.5.,
9.33.5.2.
ovens, 9.10.22.1.
pipes, 6.7.1.2., 9.33.8.3.
propane ranges, 9.10.22.1.
siding above ground, 9.27.2.4.
siding to roof, 9.27.2.4.
smoke chambers, 9.22.9.3.
solid-fuel-burning appliances, 9.33.5.3.
solid-fuel fired appliances, 6.2.1.5.
stucco from ground, 9.28.1.4.
supply ducts, 6.3.2.6., 9.33.6.8.
unit heaters, 6.4.2.1.
vented products of combustion, 6.3.3.1.
window frames, 9.27.9.5., 9.27.10.4.
wood-frame construction, 9.23.2.2.
wood above ground, 9.3.2.9., 9.23.2.3.
Climatic data, 1.1.3., 9.36.5.5.
Closures
(see also Doors; Windows)
chutes, 3.6.3.3.
definition, 1.4.1.2.[A]
door latches, 3.1.8.15., 3.4.6.16., 9.10.13.9.
elevator shaft openings, 3.2.6.5.
exterior wall openings, 3.2.3.5.
fire dampers, 9.10.13.13.
fire-protection rating, 3.1.8.4., 3.1.8.5., 9.10.13.1.
in fire separations, 3.2.8.2., 3.3.3.5., 9.10.9.3.,
9.10.13., 9.10.13.8.
glass blocks, 3.1.8.16., 3.2.3.5., 9.10.13.7.
hold-open devices, 3.1.8.14., 9.10.13.11.
installation, 3.1.8.5., 9.10.13.1.
protection of exit facilities, 3.2.3.13.
self-closing devices, 3.1.8.13., 3.4.6.13., 9.9.6.7.,
9.10.13.10., 9.10.13.15.
temperature limits, 3.1.8.17.
twenty-minute, 3.1.8.12.
unprotected openings, 3.2.3.1.
wired glass, 3.1.8.16., 3.2.3.5.
Cold weather requirements
concrete, 9.3.1.9.
excavations, 9.12.1.3.
gypsum board, 9.29.5.10.
HVAC systems and equipment, 6.2.1.6., 9.33.4.5.
Index
Index British Columbia Building Code 2018
masonry, 9.20.14.
stucco, 9.28.6.1.
Collar ties, 9.23.14.7.
Columns
anchorage, 9.23.6.2., 9.35.4.3.
carports, 9.35.3.4., 9.35.4.2., 9.35.4.3.
concrete, 9.17.6.
fire-resistance rating, 9.10.8.3.
garages, 9.35.4.2., 9.35.4.3.
heavy timber construction, 3.1.4.7.
housing and small buildings, 9.17.
lateral support, 9.17.2.2.
masonry, 9.17.5.
steel, 9.10.14.5., 9.10.15.5., 9.17.3.
supported on masonry or concrete, 9.20.8.4.
wood, 9.10.14.5., 9.10.15.5., 9.17.4.
Combustible cladding, 3.2.3.7., 9.10.14.5., 9.10.15.2.
Combustible construction
definition, 1.4.1.2.[A]
exterior cladding, 3.1.4.8.
fire-retardant-treated wood in, 3.1.4.5., 3.1.4.8.
foamed plastics in, 3.1.4.2., 9.10.17.10.
heavy timber in, 3.1.4.6., 3.1.4.7.
materials permitted, 3.1.4.1.
projections, 9.10.12.4., 9.10.14.5., 9.10.15.5.
raceways in, 3.1.4.4.
supports, 3.1.8.2., 9.10.9.8.
wires and cables in, 3.1.4.3.
Combustible content, 3.2.8.8.
Combustible dusts
definition, 1.4.1.2.[A]
and fire hose nozzles, 3.2.5.11.
Combustible fibres
definition, 1.4.1.2.[A]
storage building classification, 3.1.2.6.
Combustible gases
compressed, indoor storage, 3.3.6.3.
storage, 3.3.6.2.
Combustible liquids
definition, 1.4.1.2.[A]
storage, 3.3.2.16., 3.3.4.3.
storage and dispensing rooms, 3.3.6.4.
Combustible materials
clearances to ducts, 3.6.5.6., 6.3.2.6., 9.33.6.8.
in combustible construction, 3.1.4.1.
in noncombustible construction, 3.1.5.2., 3.1.5.6.,
9.10.6.
storage, 3.3.6.2.
Combustible piping
drain, waste and vent, 3.1.9.5., 9.10.9.7.
in noncombustible construction, 3.1.5.19.
in sprinkler systems, 3.1.9.5., 3.2.5.13., 9.10.9.6.
in vacuum cleaning systems, 3.1.9.5.
for water distribution, 3.1.9.5., 9.10.9.6.
Combustible projections
exposing building face, 3.2.3.6., 9.10.14.5., 9.10.15.5.
at firewalls, 3.1.10.7.
limiting distance, 3.2.3.6.
soffit protection, 3.2.3.16., 9.10.12.4.
Combustible refuse storage, 3.6.2.5.
Combustion venting, 6.3.3.1., 9.32.3.8.
Commercial cooking equipment, 3.3.1.2., 6.3.1.7.,
9.10.1.4., 9.10.13.13.
Communication, voice (see Voice communication
systems)
Compatibility
fasteners for cladding, 9.27.5.5.
resistance to deterioration, 5.1.4.2.
Compliance
definition, 1.2.1.1.[A]
energy performance, 2.2.8.3.[C]
Concealed spaces
fire blocks in, 3.1.11.1., 3.1.11.3., 3.1.11.4., 3.1.11.5.,
3.1.11.7., 9.10.16., 9.10.16.1.
above fire separations, 3.1.8.3.
fire separations in, 3.6.4.2., 3.6.4.3., 9.10.9.10.
insulation, 3.1.11.2.
Concrete
admixtures, 9.3.1.8.
aggregate for, 9.3.1.1., 9.3.1.4., 9.3.1.7.
cantilevered precast steps, 9.8.10.
cellular, 9.20.2.4.
chimneys, 1.4.1.2.[A], 6.3.3.2., 9.21., 9.33.10.3.
cold weather requirements, 9.3.1.9.
columns, 9.17.6.
dampproofing, 9.13.2.3., 9.13.2.4., 9.13.2.5.
design, 4.2.3.5., 4.2.3.6., 9.3.1., 9.4.1.1.
flues, 9.21.
foundations, 4.2.3.5., 4.2.3.6., 9.15.
joints, 9.15.4.9.
mixes, 9.3.1.7.
plain, reinforced and prestressed, 4.3.3., 9.3.1.
roof tiles, 9.26.2.1., 9.26.17.
slabs, for floors-on-ground, 9.16.4., 9.25.2.3.,
9.33.6.7.
stairs, 9.8.9.2., 9.8.10.
standards for, 9.3.1.1., 9.3.1.3.
Index
British Columbia Building Code 2018 Index
strength, compressive, 9.3.1.6.
structural design basis, 4.3.3.1.
sulphate-resistant, 9.3.1.3.
surface finish, 9.16.4.1.
as thermal barrier, 3.1.5.14., 3.1.5.15.
topping, 9.16.4.2., 9.23.4.4.
water used in, 9.3.1.5.
Concrete block, 9.15.2.2., 9.17.5.1., 9.20.2.6.
Condensation control
air barrier systems, 9.25.3.1.
in exhaust ducts, 6.3.2.10.
and heat transfer, 5.3.1.2.
properties, 9.25.5.1.
scope of Code, 5.1.1.1.
thermal insulation, 9.25.2.1.
vapour barrier properties, 5.5.1.2.
vapour barriers, 9.25.4.3.
Conditioned space, 1.4.1.2.[A]
Conflicting requirements, 1.5.1.2.[A]
Connected buildings, 3.2.6.3.
Construction
relative to occupancy, 9.10.8.
review of work, 2.2.7.2.[C]
types, 9.10.6.
Construction camps, 9.10.21.
Construction sites
excavations, 8.2.2.
guard persons, 8.2.1.4.
repair of damaged public property, 8.2.3.4.
safety measures, 8.1.
unoccupied, 8.2.1.5.
use of streets or public property, 8.2.3.
vehicular traffic control, 8.2.4.
warning lights, 8.2.3.5.
waste material, 8.2.5.
Constructor, definition, 1.4.1.2.[A]
Contained use areas
definition, 1.4.1.2.[A]
doors and door hardware, 3.3.1.13., 3.4.6.11.,
3.4.6.16.
fire alarm systems, 3.2.4.1.
fire annunciators, 3.2.4.8.
fire separations, 3.3.3.7.
smoke detectors, 3.2.4.11.
sprinkler system requirements, 3.2.2.19.
Contaminated air
minimum distances of air intakes from, 6.3.2.9.
movement, 3.2.6.2., 3.2.6.3.
removal, 6.3.1.6., 6.3.2.14.
Continental seating, 3.3.2.4.
Controls
accessible 3.8.2.6., 3.8.3.8., 3.8.3.10., 3.8.3.16.,
3.8.3.17.
location, 3.8.3.8.
operation, 3.8.3.8.
temperature, 9.33.4.3.
Convalescent homes
fire alarm systems, 3.2.4.3.
as residential occupancies, 3.1.2.5., 9.10.2.2.
Convectors, 9.33.7.1.
Cooking equipment, commercial, 3.3.1.2., 6.3.1.7.,
9.10.1.4., 9.10.13.13.
Cooktops
(see also Stoves)
clearances, 9.10.22.1., 9.10.22.2.
definition, 1.4.1.2.[A]
fans, 9.32.3.11.
hoods, 9.32.3.11.
installation, 9.10.22.1., 9.33.5.3.
protection around, 9.10.22.3.
Coolers, walk-in, 3.1.4.2., 3.1.5.7., 9.10.17.10.
Cooling systems and equipment
installation, 6.6.1.1., 9.33.9.1.
structural movement, 4.1.8.18., 6.2.1.4., 9.33.4.7.
system pressure, 6.2.1.3., 9.33.4.6.
Cooling towers and sections, 6.3.2.15.
Corbelling, 9.15.4.8., 9.20.12.
Cornices, 3.1.11.5.
Corridors
(see also Public areas; Public corridors)
access to exit, 3.3.2.6., 9.9.7.
assembly occupancy, 3.3.2.6.
care, treatment or detention occupancy, 3.3.3.3.,
3.3.3.5.
dead-end, 3.1.8.17., 3.3.1.9., 3.3.3.3., 3.3.4.4., 9.9.7.3.
dimensions, 3.3.1.9., 9.9.5.2.
doors opening into, 3.3.1.11., 9.9.6.1.
emergency lighting, 3.2.7.3.
fire separations, 9.10.9.15.
flame-spread rating, 3.1.13.6., 9.10.21.6.
illumination, 3.2.7.1., 3.2.7.3.
loads on floor or roof, 4.1.5.3., 4.1.5.4.
obstructions, 3.3.1.9., 9.9.5.2., 9.9.5.3., 9.9.6.1.
paired doors in, 3.3.3.3.
serving patients’ sleeping rooms, 3.3.3.5.
sliding glass partitions, 9.6.1.4.
smoke detectors, 3.2.4.11.
temperature rise and area limits exception, 3.1.8.19.
Index
Index British Columbia Building Code 2018
transparent doors in, 3.3.1.19.
transparent panels in, 3.3.1.19.
width, 3.3.1.9., 9.9.3.3., 9.9.5.2.
width, in dwelling units, 9.5.4.1.
windows in, 3.3.1.19.
Corrosion protection
(see also Corrosion resistance)
pipes, 9.31.2.2.
service water heaters, 9.31.6.3.
steel beams, 9.23.8.2.
steel lintels, 9.20.5.2.
Corrosion resistance
(see also Corrosion protection)
ducts, 6.3.2.3., 9.33.6.2., 9.33.6.7.
elements in environmental separators, 5.1.4.2.
fasteners for cladding, 9.27.5.5.
masonry connectors, 9.20.16.1.
plumbing, 9.31.2.2.
screens and grilles, 6.3.2.9., 9.32.3.13.
service water heaters, 9.31.6.3.
Counters
for service to the public, 3.8.3.1., 3.8.3.19.
for telephones, 3.8.3.20.
Covered ways, 8.2.1.1., 8.2.1.2.
Coverings
ducts, 3.6.5.4., 6.3.2.5., 9.33.6.4.
pipes, 6.3.2.5.
Crack control joints, 9.15.4.9.
Cranes, loads due to, 4.1.3.2., 4.1.5.11.
Crawl spaces
access, 3.6.4.6., 9.18.2.1., 9.18.4.1.
air barrier systems in, 9.18.1.3.
application of Code, 3.6.1.1.
clearance, 9.18.4.1.
drainage, 9.18.5.
fire blocks in, 3.1.11.1., 3.1.11.6.
fire resistance of floors over, 9.10.8.1., 9.10.9.4.
fire separations, 3.3.1.4.
flame-spread rating, 9.18.7.1.
ground cover, 9.18.6.
heated, 9.13.4.2., 9.18.1.3., 9.33.3.1.
housing and small buildings, 9.18.
insulation, 9.18.1.3., 9.25.2.2., 9.25.2.3.
regulated as basements, 3.2.2.9., 9.10.8.9.
return-air inlets, 9.33.6.12.
supply outlets, 9.33.6.11.
unheated, 9.18.1.3.
vapour barrier in, 9.18.1.3.
ventilation, 6.3.1.2., 9.18.3.
as warm-air plenums, 9.18.7.1.
Curbs, repair and storage garages, 3.3.5.4., 9.8.8.4.
Curtain walls (see Fenestration)
Curved roofs, snow and rain loads, 4.1.6.10.
Cutting operations room, 3.3.1.25.
D
Dampers
(see also Fire dampers)
access, 6.2.1.6., 9.33.4.4.
adjustable, 9.33.6.9.
fireplaces, 9.22.6.1.
Dampproofing
crawl spaces, 9.18.6.
floors, 9.23.2.3.
floors-on-ground, 9.13.2.1., 9.13.2.6.
foundations, 9.13.2.
installation, 9.13.2.4.
material standards, 5.9.1.1., 9.13.2.2.
preparation of surface, 9.13.2.3.
protection from groundwater, 5.7.3.4.
protection of interior finishes, 9.13.2.5., 9.20.13.9.,
9.23.2.3.
requirement for, 9.13.2.1.
walls, 9.13.2.1., 9.13.2.3., 9.13.2.4., 9.20.13.9.,
9.23.2.3.
Dance halls
access to exit, 3.3.1.17.
principal entrances, 3.4.2.6.
Dangerous goods
access openings, 3.2.5.1.
definition, 1.4.1.2.[A]
hazardous areas design, 3.3.6.
process plants, 3.3.6.8., 3.3.6.9.
storage, 3.3.6.2., 3.3.6.3.
Dead-end corridors, 3.1.8.17., 3.3.1.9., 3.3.3.3., 3.3.4.4.,
9.9.7.3.
Dead loads, 1.4.1.2.[A], 4.1.3.2., 4.1.4., 9.4.3.1.
Decay, protection against, 9.3.2.9., 9.23.2.2., 9.23.2.3.
(see also Deterioration)
Decking for wood shingled roofs, 9.26.9.1.
Decks
foundations, 9.12.2.2.
snow loads, 9.4.2.3.
sprinkler systems, 3.2.5.12.
Deep foundations
damaged, 4.2.7.6.
definition, 1.4.1.2.[A]
Index
British Columbia Building Code 2018 Index
design, 4.2.7.2.
installation, 4.2.7.5.
load testing, 4.2.7.2.
location and alignment, 4.2.7.3., 4.2.7.4.
Definitions of words and phrases, 1.4.1.2.[A], 4.1.3.1.
Deflections
air barrier systems, 5.2.2.1., 5.4.1.1.
structure, 4.1.3.5., 4.1.8.13., 9.4.3.
Deformation resistance, 5.2.2.1., 9.12.2.2., 9.15.1.3.
Demolition sites, safety measures, 8.1.1.3.
Depressurization, protection against, 9.32.3.8.
Design
environmental separation, 5
HVAC systems, 6.2.1.1., 9.33.1.1., 9.33.4.1.
structural, 4, 9.4.
Design calculations and analyses, 2.2.4.5.[C]
Designer
definition, 1.4.1.2.[A]
of parts and components, 2.2.4.4.[C]
as reviewer of work, 2.2.7.2.[C], 2.2.7.3.[C],
2.2.7.4.[C]
signature requirements, 2.2.4.2.[C], 2.2.4.4.[C]
structural, requirements for, 2.2.1.2.[C]
subsurface inspection, 4.2.2.3., 4.2.2.4., 4.2.4.1.
Design temperatures
indoor, 5.2.1.2., 5.3.1.2., 5.5.1.2., 9.33.3.1.
outdoor, 1.1.3.1., 5.2.1.1., 5.3.1.2., 5.5.1.2., 6.2.1.2.,
9.33.3.2., 9.33.5.1.
Detectors
carbon monoxide, 6.3.1.4., 6.9.3.1., 9.32.3.8.,
9.32.3.9.
fire, 1.4.1.2.[A], 3.2.4.4., 3.2.4.10.
heat, 1.4.1.2.[A], 9.10.18.3., 9.10.18.4.
smoke, 1.4.1.2.[A], 3.1.8.14., 3.2.4.8., 3.2.4.11.,
3.2.4.12., 3.2.4.14., 3.2.4.20., 3.2.4.21., 3.6.2.7.,
6.9.2.2., 9.10.18., 9.10.18.3., 9.10.18.4., 9.10.18.5.,
9.10.21.7.
sprinklers installed in lieu of, 9.10.18.4.
Detention occupancy (see Care, treatment or
detention occupancy)
Deterioration
(see also Decay, protection against)
due to moisture, 5.5.1.2.
resistance to, 5.1.4.2., 9.20.16.1.
Diaphragms, earthquake design, 4.1.8.15.
Differential movement
columns, 9.17.2.2.
decks and other accessible platforms, 9.12.2.2.,
9.23.6.2.
elements in environmental separation, 5.1.4.1.,
5.2.2.1.
metal and vinyl cladding, 9.27.5.6.
Diffusers, 3.6.5.7., 9.33.6.10., 9.33.6.11.
(see also Air outlets)
Dining areas, loads, 4.1.5.6.
Direct-vented, 1.4.1.2.[A]
Dispensing rooms, flammable and combustible
liquids, 3.3.6.4.
Distilled beverage alcohol, 1.4.1.2.[A]
Distilleries, 1.4.1.2.[A], 3.2.5.11.
Distribution panel, emergency lighting, 3.2.7.10.
Domes, snow and rain loads, 4.1.6.10.
Door assemblies
as fire-protection closures, 3.1.8.5.
leakage rates, 3.1.8.4.
Door frames
caulking, 9.20.13.11.
sealant, 9.27.4.1.
steel, 9.10.13.6.
thermal breaks, 9.7.3.3.
wood, 9.10.13.3.
Doors
(see also Closures; Doorways)
action of, 9.9.6.4.
airtightness, 9.36.2.9., 9.36.2.10.
area, calculating, 9.36.2.3.
accessible path of travel, 3.8.3.6.
in bedrooms, 9.9.10.1.
containing foamed plastics, 3.1.4.2.
in corridors, 3.3.1.13., 3.3.3.3., 9.9.6.1., 9.10.13.
dimensions, 3.3.3.4., 9.5.5., 9.9.6.3.
direction of swing, 3.3.1.11., 3.3.3.3., 3.4.6.10.,
3.4.6.12., 3.6.2.6., 9.9.6.5., 9.10.13.12.
between dwelling unit and garage, 9.10.13.15.
in dwelling units, 3.1.13.2.
emergency crossover access to floor areas, 3.4.6.18.
for exits, 3.1.8.14., 3.4.5.1., 3.4.6.11., 3.4.6.12.,
3.4.6.16., 9.9.6.
exterior, 5.3.1.2., 5.4.1.2., 9.7.4.3., 9.7.5.2.
in fire separations, 3.1.8.12. - 3.1.8.15., 3.1.8.17.,
3.3.3.5., 9.10.13.
flame-spread rating, 3.1.13.2., 3.1.13.7., 9.10.17.1.
force required to open, 9.9.6.8.
glass or transparent, 3.3.1.19., 3.4.1.8., 9.6., 9.6.1.3.,
9.9.4.3.
hardware (see Hardware for doors)
housing and small buildings, 9.7.
incinerator rooms, 3.6.2.6.
Index
Index British Columbia Building Code 2018
installation, 9.7.6.
at landings, 9.8.6.2.
manufactured and pre-assembled, 9.7.4.
in means of egress, 3.3.1.13., 3.4.6.10., 3.4.6.11.,
9.9.6., 9.9.7., 9.10.13.
in means of egress from dwelling units, 9.9.9.
in means of egress from suites, 9.9.6., 9.9.7.4.,
9.9.7.6., 9.9.8.
near steps or stairs, 3.4.6.11., 9.8.6.2., 9.9.6.6.
opening onto landings, 9.8.6.3.
performance expectations, 9.7.3.
power operators, 3.8.2.7., 3.8.3.6.
protection, 9.8.8.1.
resistance to forced entry, 9.7.5.2.
revolving, 3.4.6.15., 9.9.6.4.
service rooms, 3.6.2.6., 9.10.13.12.
site-built, 9.7.5.
sliding (see Sliding doors)
in smoke-tight barriers, 9.10.9.3.
of solid core wood, 9.10.13.
standards for, 5.3.1.2., 5.4.1.2., 9.7.4., 9.10.13.2.
storage garages, 9.9.6.4.
storage suites, 9.9.6.4.
storm, 5.9.2.4., 9.6.1.4., 9.7.3.1., 9.7.3.3.
temperature limits, 3.1.8.17.
thermal breaks, 5.9.2.4., 9.7.3.3.
thermal characteristics, 9.36.2.7.
thresholds, 3.3.1.13., 3.4.6.1., 3.8.3.6., 3.8.3.16.
water-closet stalls, 3.8.3.11.
Door stops, 9.10.13.16.
Doorways
(see also Doors)
barrier-free path of travel, 3.8.3.6.
bathrooms, 9.5.5.3.
dimensions, 3.3.3.4., 3.4.3.2., 9.5.5., 9.7.2.2., 9.9.6.2.,
9.9.6.3.
between dwelling unit and garage, 9.10.13.15.
dwelling units, 9.5.5.1.
headroom clearance, 3.4.3.4.
at landings, 9.8.6.2., 9.8.6.3.
means of egress, 3.3.1.5.
means of egress from dwelling units, 9.9.9.
means of egress from suites, 3.3.1.3., 3.3.1.5.,
9.9.7.2., 9.9.7.4., 9.9.7.6., 9.9.8.
near stairs, 9.8.6.2.
obstructions, 9.9.6.1., 9.9.6.3.
at ramp landings, 9.8.6.3.
secondary suites, 9.5.5.1.
service rooms, 9.9.5.9.
water closet rooms, 9.5.5.2.
width, 3.3.3.4., 3.4.3.2.
Downspouts, 5.6.2.2., 9.14.6.5., 9.26.18.1.
Draft stops, 3.2.8.6.
Drainage
above-ground masonry walls, 9.20.13.9.
building envelopes, 5.6.2.2.
crawl spaces, 9.18.5.
disposal, 5.6.2.2., 9.14.5.
evacuation site, 9.14.4.3.
floors, 9.16.3.3.
floors-on-ground, 9.16.3.
footings, 9.14.
foundations, 9.14.2., 9.35.3.3.
granular layer installation, 9.14.4.2., 9.14.4.4.
granular layers, 9.14.2.1., 9.14.4.
granular material, 9.14.4.1.
housing and small buildings, 9.14.
pipes, 9.14.3.
pipes and tiles installation, 9.14.3.3.
roofs, 5.6.2.2., 9.26.18.
second plane of protection, 9.27.3.
surface water, 5.7., 9.12.3.2., 9.14., 9.14.6.
tiles, 9.14.3.
underground ducts, 6.3.2.12., 9.33.6.7.
Drainage systems, sanitary, 1.4.1.2.[A], 9.31., 9.31.2.1.,
9.31.5.
(see also Plumbing)
Drain pans, 6.3.2.2.
Drains
floors, 9.31.4.3.
from noncombustible water closets, 9.10.9.7.
roofs, 5.6.2.2., 9.26.18.2.
Drain, waste and vent piping, 3.1.9.5., 9.10.9.7.
(see also Plumbing)
Draperies, in exits, 9.9.5.6.
Drift limits, earthquake design, 4.1.8.13.
Drilling of framing members, 9.23.5.1.
Drinking fountains, 3.8.2.8., 3.8.3.10.
Dry standpipes, 3.2.5.9.
Dry wells, 9.14.5.3.
Ducts
access, 3.6.4.5., 6.2.1.6., 9.33.4.4.
access openings, 6.3.2.4.
adhesives, 3.6.5.4., 9.33.6.4.
air filters in, 6.8.1.3.
aluminum, 9.33.6.5.
in ceiling spaces, 3.1.9.6., 9.10.5.1.
cleaning, 6.2.1.6., 9.33.4.4.
Index
British Columbia Building Code 2018 Index
clearances, 3.6.5.6., 6.3.2.6., 9.22.9.4., 9.33.6.8.
combustible, 3.6.5.1., 9.33.6.2.
in or beneath concrete slabs, 9.33.6.7.
connections, 6.3.2.4., 9.33.6.6., 9.33.6.7.
connectors, 3.6.5.1., 6.3.2.3., 6.3.2.18., 9.33.6.2.
construction, 9.33.6.6.
for cooking equipment, 3.1.8.8., 3.1.8.9., 3.6.3.5.
coverings, 3.6.5.4., 6.3.2.5., 9.10.17.12., 9.33.6.4.
design, 6.2.3., 9.33.6.1., 9.33.6.5.
dimensions, 9.32.3.11.
drainage, 6.3.2.12., 9.33.6.7.
drain pans, 6.3.2.2.
exhaust (see Exhaust ducts)
in exits, 6.9.2.4.
in fire-rated assemblies, 3.1.9.6., 9.10.5.1., 9.10.9.6.
fire stops, 9.33.6.6.
fittings, 6.3.2.3., 9.32.3.11., 9.33.6.2., 9.33.6.5.
galvanized, 9.33.6.5.
installation, 6.2.3., 9.33.6.1., 9.33.6.7.
insulation, 3.6.5.4., 6.3.2.5., 9.32.3.11., 9.33.6.4.
interconnection, 6.3.2.7., 9.33.6.7.
joints, 6.3.2.4., 9.32.3.11., 9.33.6.3., 9.33.6.6., 9.33.6.7.
leakage, 6.3.2.7.
linings, 3.6.5.4., 6.3.2.5., 9.10.17.12., 9.33.6.4.
materials, 6.3.2.3., 9.32.3.11., 9.33.6.2.
metal, 9.33.6.5.
noncombustible, 3.1.8.8., 3.1.8.9., 3.6.5.1.
in noncombustible construction, 3.1.5.18.
penetrating fire blocks, 9.10.16.4.
penetrating fire separations, 3.1.8.7., 3.1.8.8.,
3.1.8.9., 3.1.9.2., 9.10.9.6., 9.10.13.13.
penetrating fire stops, 3.1.11.7.
return air systems, 1.4.1.2.[A], 3.6.5.8., 6.3.2.11.,
9.33.6.7., 9.33.6.13.
sealing, 3.6.5.3., 6.3.2.19., 9.32.3.11., 9.33.6.3.,
9.33.6.7.
smoke detectors in, 6.9.2.2.
supply, 9.32.3.11., 9.33.6.7.
systems, 6.2.3., 9.33.6.
trunk, 9.33.6.7.
underground, 6.3.2.12., 9.33.6.7.
ventilation, 6.2.3., 9.32.3.11., 9.33.6.2.
Duct-type smoke detectors, 3.2.4.12.
Dumbwaiters, 3.5.1.1., 3.5.2.1., 3.5.3.2.
Dusts, hazardous, 6.9.1.2.
Dwelling units
(see also Housing and small buildings)
alarm audibility, 3.2.4.18.
combustible projections, 3.2.3.6., 9.10.14.5.
definition, 1.4.1.2.[A]
doors in means of egress, 9.9.6.
door swing, 3.4.6.12., 9.9.6.5.
doorways, 9.5.5., 9.9.6.2., 9.9.6.3.
egress, 3.3.4.4., 9.9.9.
electrical outlets, 9.34.2.2.
exception for combustible projections, 9.10.15.5.
fire alarms, 9.10.18.2.
fire alarm systems, 3.2.4.1.
fire detectors, 3.2.4.10.
fire protection, 3.2.2.47. - 3.2.2.54., 9.10.
fire-protection closures, 3.1.8.5.
fire-resistance rating, 9.10.8.10.
fire separations, 3.3.4.2., 9.9.4., 9.10.9.4., 9.10.9.11.,
9.10.9.12., 9.10.9.14.
firewalls, 9.10.11.2.
floors-on-ground, 9.16.1.3.
guards, 3.3.4.7., 9.8., 9.8.8.
hallways, 9.5.4.1.
handrails, 3.3.4.7., 9.8., 9.8.7.
height of rooms and spaces, 3.7.1.1., 9.5.3.
landings, 9.8.6., 9.8.6.3.
manual fire alarm stations, 3.2.4.16.
ramps, 9.8., 9.8.5.2.
secondary suites, 9.1.2.1.
in self-service storage buildings, 3.9.3.1.
shared egress facilities, 9.9.9.3.
smoke alarms, 3.2.4.20., 9.10.19.
sound control, 3.3.4.6., 5.8.1.1., 9.11.
spatial separation between houses, 9.10.15.
sprinkler systems, 3.2.5.12.
stairs, 3.3.4.7., 9.8.
travel limit to exits, 9.9.9.1.
uniformity of runs in flights with mixed treads,
9.8.4.5.
water closets, 9.31.4.1.
Dynamic procedure
earthquake load and effects calculations, 4.1.8.12.
wind load calculations, 4.1.7.8.
E
Earthquake design
accidental torsional effects, 4.1.8.12.
analysis, 4.1.8.1., 4.1.8.7.
anchorage of building frames, 9.23.6.1.
bracing to resist lateral loads, 9.23.13.
building strength and stability, 4.1.3.2.
deflections, 4.1.8.13.
Index
Index British Columbia Building Code 2018
direction of loading, 4.1.8.8.
dynamic analysis, 4.1.8.12.
equivalent static force analysis, 4.1.8.11.
fasteners for sheathing or subflooring, 9.23.3.5.
foundations, 4.1.8.16., 4.1.8.17.
joints in top plates of loadbearing walls, 9.23.11.4.
masonry walls, 9.20.1.2., 9.20.15.
notation, 4.1.8.2.
requirements, 4.1.8.3.
roof sheathing, 9.23.16.1.
seismic force reduction factors and system
overstrength factors, 4.1.8.9.
seismic isolation, 4.1.8.19., 4.1.8.20.
site properties, 4.1.8.4.
special provisions, 4.1.8.10., 4.1.8.15.
structural irregularities, 4.1.8.6.
structural separation, 4.1.8.14.
supplemental energy dissipation, 4.1.8.21., 4.1.8.22.
Eave projections, 9.10.14.5., 9.10.15.5., 9.26.5.
Eave protection, 9.26.2.1., 9.26.5.1., 9.26.5.2.
Effective thermal resistance (RSI value), definition,
9.36.1.2.
Egress (see Doors; Doorways; Means of egress)
Egress doorways, 3.3.1.5., 3.3.1.6.
Electrical conductors
protection of, 3.2.7.10.
tests, 3.2.7.10.
Electrical equipment, 3.6.1.2., 9.33.5.2., 9.34.
Electrical equipment vaults, 3.6.2.7.
Electrical supervision, fire alarm systems, 3.2.4.9.
Electrical wiring
exit signs, 3.4.5.2.
housing and small buildings, 9.34.
service facilities, 3.6.1.2.
Electric cables, storage, 3.3.6.2.
Electromagnetic locking device, 3.3.1.13., 3.4.6.16.,
3.4.6.18., 9.9.6.7.
Elevating devices, 3.8.2.3., 3.8.3.7.
Elevator cables, 3.1.5.22.
Elevator cars, flame-spread rating, 3.1.13.11.
Elevators
application of Code, 3.5.1.1.
accessible path of travel, 3.3.1.7., 3.8.2.3., 3.8.3.2.,
3.8.3.7.
dimensions, 3.5.4.1.
earthquake design, 4.1.8.18.
emergency operation, 3.2.6.4., 3.2.7.9.
emergency recall, 3.2.4.14., 3.2.6.4.
for firefighters, 3.2.6.5., 3.2.7.9.
fire protection, 9.10.1.3.
flame-spread rating, 3.1.13.7.
high buildings, 3.2.7.9.
hoistway noise, 5.8.1.1.
hoistways, 3.2.6.4., 3.2.6.6., 3.2.8.4., 3.5.3.1., 3.5.3.3.,
3.5.4.2., 9.10.18.4.
machine rooms, 3.2.1.1., 3.2.2.14., 3.2.5.12., 3.5.3.3.
not a means of egress, 9.9.2.3.
smoke detectors, 3.2.4.11., 3.2.4.14.
standards, 3.5.2.1., 3.8.3.7.
Emergency cables and conductors, 3.2.7.10.
Emergency elevators, 3.2.6.4., 3.2.6.5., 3.2.7.9.
Emergency lighting, 3.2.7.3., 3.2.7.4., 3.2.7.10., 9.9.12.,
9.9.12.3.
Emergency power supply
exit signs, 9.9.11.3.
installation, 3.2.7.5., 3.6.2.8.
lighting, 3.2.7.4., 9.9.12.3.
smoke alarms, 9.10.19.4.
Emergency return, elevators, 3.2.4.14., 3.2.6.4.
Energy efficiency
building envelope, 9.36.2.
definition, 9.36.1.2.
energy performance compliance, 9.36.5.
housing and small buildings, 9.36.
HVAC systems and equipment, 9.36.3.
service water heating systems, 9.36.4.
Energy performance
compliance, 9.36.5.
definitions, 9.36.5.2.
drawings and specifications, 2.2.8.[C]
Energy step code, 9.36.6., 10.2.3.
Entrances, accessible, 3.8.2.2.
Environmental loads, 5.1.4.1., 5.2.1., 5.2.1.3., 5.9.3.2.
Environmental separation
air leakage, 9.25., 9.25.3.
application of Code, 5
compliance with standards, 5.9.1.1.
condensation control, 9.25.
crawl spaces, 9.18.
dampproofing, 9.13., 9.13.2.
drawings and specifications, 2.2.5.2.[C]
fire (see Fire separations)
heat transfer, 9.25., 9.25.2.
roof spaces, 9.19.
soil gas control, 9.13., 9.13.4.
sound control, 5.8.1., 9.11.
waterproofing, 9.13., 9.13.3.
Equipment
Index
British Columbia Building Code 2018 Index
air-conditioning, 9.33.5.
characteristics, 1.2.2.1.[A]
cooking, 3.3.1.2., 6.3.1.7., 9.10.1.4., 9.10.13.13.
electrical installations, 9.33.5.2., 9.34.1.1.
HVAC, 6.1.1.2., 9.33.1.1., 9.33.5.
loads on floors and roofs, 4.1.5.3.
odour removal, 9.33.6.14.
space cooling, 9.33.5.2., 9.33.9.
space heating, 9.33.5.2.
storage, 1.2.2.2.[A]
used, 1.2.2.3.[A]
Escalators, 3.2.8.2., 3.5.1.1., 3.5.2.1., 3.8.2.4., 9.10.1.3.
earthquake design, 4.1.8.18.
Evaporative air coolers, 6.3.2.16.
Evaporative condensors, 6.3.2.15.
Evaporative cooling towers, 6.3.2.15.
Evaporative fluid coolers, 6.3.2.15.
Excavations
backfill, 9.12.3.
definition, 1.4.1.2.[A]
depth, 9.12.2.
design of, 4.2.5.1.
erosion, 4.2.5.6.
grading, 9.14.4.3.
housing and small buildings, 9.12.
native soil, 9.12.1.1.
organic material, 9.12.1.1.
protection from freezing, 4.2.5.7., 9.12.1.3.
safety measures, 8.2.2.
structural design, 4.2.5.
support of, 4.2.5.3.
water control, 4.2.5.5.
water in, 8.2.2.1., 9.12.1.2.
Exhaust
capacity, 9.32.3.3., 9.32.3.4., 9.32.3.7.
discharge, 6.3.2.10.
fans, 9.32.3.7.
to garages, 6.3.2.10.
intakes, 9.32.3.3., 9.32.3.5., 9.32.3.7.
outlets, 3.6.5.7., 6.3.2.10.
systems, 3.2.6.6., 3.2.8.7., 3.3.1.20., 9.10.9.18.
Exhaust air openings, 6.3.2.9.
Exhaust ducts
combining, 6.3.2.10.
condensation, 6.3.2.10.
definition, 1.4.1.2.[A]
fire dampers in, 9.10.13.13.
fire dampers waived, 3.1.8.8.
insulation, 6.3.2.5., 9.32.3.11., 9.33.6.4.
interconnection, 6.3.2.7., 6.3.2.10.
laboratory enclosures, 6.3.4.3.
serving cooking equipment, 6.3.2.10.
serving laundry equipment, 6.3.2.10., 9.32.1.3.
serving more than one fire compartment, 9.10.9.18.
smoke dampers waived, 3.1.8.9.
vertical service spaces, 3.6.3.4.
Exhibitions, 3.1.2.3.
Existing buildings, application of Code, 1.1.1.1.[A]
Exits
(see also Means of egress)
access to, 3.4.6.17., 9.9.7., 9.9.7.1.
aggregate width, 3.4.3.1., 3.4.3.2., 9.9.3.
appliances in, 9.9.5.7.
balconies, 3.4.4.1.
capacity, 3.4.3.2.
combustible glazing restrictions, 3.4.1.10.
convergence, 3.4.1.2.
cumulative width, 3.4.3.2.
definition, 1.4.1.2.[A]
distance between, 3.4.2.3.
door hardware, 3.4.6.16., 3.4.6.17.
doors, 3.2.3.13., 3.4.3.3., 3.4.6.11., 3.4.6.13., 3.4.6.16.,
9.7.2.2.
door swing, 3.4.6.12.
ducts in, 6.9.2.4.
dwelling units, 3.3.4.4., 9.9.9.
emergency access, 3.4.6.18.
emergency lighting, 3.2.7.3., 9.9.12.
exterior passageways, 3.1.13.10., 3.4.1.5.
finish, interior, 9.10.17.
fire alarm systems, 3.2.4.1.
fire hose connections, 3.2.5.10.
fire separations, 3.4.4.1., 9.9.4.
from floor areas, 9.9.8.
general requirements, 9.9.2.
glass block in, 3.2.3.13., 9.9.4.3. - 9.9.4.7.
glass doors, 9.6., 9.9.4.3.
glass and transparent panels and doors, 3.4.1.8.
guards, 3.4.6.6.
headroom clearance, 3.4.3.4., 9.8.2.2., 9.9.3.4.,
9.9.6.2.
horizontal, 3.4.1.4., 3.4.1.6., 9.9.2.1.
housing and small buildings, 9.9.
integrity, 3.4.4.4., 9.9.4.2.
interconnected floor space, 3.2.8.4., 3.4.3.2.
landings, 9.8.1.3.
level, lowest, and smoke contamination, 3.2.6.2.
levels, 1.4.1.2.[A], 3.2.6.2.
Index
Index British Columbia Building Code 2018
lighting, 3.2.7.1., 9.9.12.
loads on floor or roof, 4.1.5.3.
through lobbies, 3.4.4.2., 9.9.8.5.
location, 3.4.2.5., 9.9.8.4.
manual fire alarm stations, 3.2.4.16.
from mezzanine, 3.4.2.2., 9.9.8.6.
minimum number, 3.4.2.1.
mirror restrictions, 3.4.1.9., 9.9.5.6.
number, 9.9.7.1., 9.9.7.2., 9.9.8.2., 9.9.9.
obstructions, 3.4.6.11., 9.9.5., 9.9.5.5., 9.9.6.1.,
9.9.6.2., 9.9.11.2.
obstructions permitted, 3.4.3.3.
protected floor space, 3.2.8.5., 3.4.3.2.
purpose, 9.9.2.2.
ramps, 3.4.5.2.
revolving doors, 3.4.6.15., 9.9.6.4.
rooms opening into, 3.4.4.4., 9.9.5.9., 9.9.8.5.
secondary suites, 9.9.9.
separation, 3.4.1.2.
service rooms under, 3.6.2.2., 9.9.5.8.
signs, 3.4.5.1., 3.4.5.2., 9.9.11., 9.9.11.3.
smoke detectors, 3.2.4.11.
stairs, 3.4.5.2., 3.4.6.8., 3.4.6.9., 9.8.1.3., 9.8.2.1.,
9.8.3.1.
storage garages, 9.9.6.4.
storeys, 1.4.1.2.[A], 3.2.6.2.
travel distance, 3.4.2.1., 3.4.2.3., 3.4.2.4., 9.9.8.2.
types, 3.4.1.4., 9.9.2.1.
visibility, 9.9.11.2.
wall openings near, 9.9.4.4.
weather protection, 3.4.6.11.
width, 3.4.3.3., 9.9.3.2., 9.9.3.3., 9.9.8.3.
windows, 3.2.3.13., 9.7.2.2., 9.9.4.
wired glass in, 3.2.3.13., 9.9.4.3. - 9.9.4.6.
Expansion and contraction
elements in environmental separation, 5.1.4.1.,
5.2.2.1.
heating and cooling systems, 6.2.1.3., 9.33.4.6.,
9.33.8.1.
metal and vinyl siding, 9.27.5.6.
piping, 6.7.1.1., 9.33.8.1.
structural, 4.1.2.1.
Explosion venting, 3.3.1.20.
Exposing building face
area, 3.2.3.2.
area and aspect ratio, 9.10.14.5.
area and location, 9.10.14.2., 9.10.15.2.
construction, 3.2.3.7., 9.10.14.5., 9.10.15.5.
definition, 1.4.1.2.[A]
exits, 3.2.3.13.
fire resistance waived, 9.10.14.5., 9.10.15.5.
first storey facing a street, 9.10.14.4.
garage serving a dwelling unit, 9.10.14.5.
glazed openings, 9.10.15.2.
limiting distance, 3.2.3.5., 3.2.3.6., 3.2.3.7., 9.10.14.5.,
9.10.15.5.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.3.11.
in noncombustible construction, 3.1.5.5.
protection of, 3.2.3.8.
restrictions on combustible projections, 3.2.3.6.,
9.10.14.5., 9.10.15.5.
spatial separation between buildings, 9.10.14.,
9.10.15.
structural members, 3.2.3.9.
unlimited openings, 3.2.3.10., 9.10.14.4., 9.10.15.4.
unprotected openings, 3.2.3.1., 3.2.3.2., 3.2.3.12.,
9.10.14.4., 9.10.15.4.
Exterior areas, loads on, 4.1.5.5.
Exterior insulation finish systems, 5.9.4., 9.27.12.
Exterior ornamentations
earthquake loads, 4.1.8.1.
wind loads, 4.1.7.11.
F
Fabrics, for canopies and marquees, 3.1.16.1.
Factories
loads on floor or roof, 4.1.5.3.
storage areas, 4.1.5.3.
Factory-built chimneys, 1.4.1.2.[A], 9.33.10.2.
Factory-constructed buildings, 1.1.1.1.[A]
Falsework, 4.1.1.3.
Fans
access, 6.2.1.6., 9.33.4.4.
auxiliary, 9.32.3.4.
bathrooms, 9.32.3.3.
capacity, 9.32.3.3., 9.32.3.10.
controls, 9.32.3.3.
cooktops, 9.32.3.7., 9.32.3.11.
dehumidistat, 9.32.3.3., 9.32.3.7.
emergency power supply, 3.2.7.9.
emergency stoppage, 3.2.6.2.
exhaust, 9.32.3.3., 9.32.3.5.
housing and small buildings, 9.32.3.
installation, 6.3.2.17., 9.32.3.3. - 9.32.3.6., 9.32.3.10.
kitchens, 9.32.3.3., 9.32.3.7.
location, 6.3.2.17., 9.32.3.2.
Index
British Columbia Building Code 2018 Index
noise, 9.32.3.2.
sound ratings, 9.32.3.10.
standards for, 9.32.3.10.
supplementary exhaust, 9.32.3.7.
supply, 9.32.3.4., 9.32.3.5.
vibration, 9.32.3.2.
Farm buildings
application of Code, 1.1.1.1.[A]
definition, 1.4.1.2.[A]
Fasteners
cladding, 9.27.5.4.
dimensions, 9.27.5.4.
gypsum board, 9.29.5.5.
roofing, 9.26.2.3., 9.26.2.4.
siding, 9.27.5.4.
standard for, 9.23.3.1.
stucco, 9.28.3.1., 9.28.3.2.
Fastening
cladding, 9.27.5.4.
furring, 9.29.3.2.
gypsum board, 9.29.5.8., 9.29.5.9.
hardboard finish, 9.29.7.3.
plywood finish, 9.29.6.3.
sheathing, 9.23.3.5.
shingles, 9.26.7.4., 9.26.8.4., 9.26.8.5.
siding, 9.27.5.4.
steel framing, 9.24.3.6.
steel studs, 9.24.1.4.
stucco lath, 9.28.4.6.
subflooring, 9.23.3.5.
underlay, 9.30.2.3.
wood-frame construction, 9.23.3.
wood shingles and shakes, 9.26.9.5., 9.26.10.3.
Faucets and other bathroom accessories, 3.7.2.3.,
3.7.2.9., 3.8.3.8., 3.8.3.11., 3.8.3.15., 3.8.3.17.
Fences, at construction and demolition sites, 8.2.1.3.
Fenestration
(see also Windows)
airtightness, 5.9.3.4., 9.36.2.9.
area, calculating, 9.36.2.3.
definition, 9.36.1.2.
heat transfer, 5.9.3.3.
resistance to water penetration, 5.9.3.5.
structural and environmental loads, 5.9.3.2.
thermal characteristics, 9.36.2.2., 9.36.2.7.
thermal resistance calculation, 9.36.2.11.
types, 5.9.3.1.
water penetration, 5.9.3.5.
Fibreboard
fastening, 9.29.8.3.
installation, 9.29.8.3., 9.29.8.4.
as insulating finish, 9.29.8.
material standard, 9.29.8.1.
nailing, 9.29.8.3.
as roof sheathing, 9.23.16.7.
thickness, 9.29.8.2.
as wall sheathing, 9.23.17.2., 9.23.17.3.
Fill
(see also Backfill; Backfilling)
definition, 1.4.1.2.[A]
beneath floors-on-ground, 9.16.2.1., 9.16.2.2.
beneath footings, 9.15.3.2.
beneath foundations, 4.2.4.13.
Filters, air, 6.8.1.3., 9.33.6.14.
Finishes
interior (see Interior finishes)
slip-resistant, 3.4.6.1.
Fire alarm and detection systems
annunciators, 3.2.4.8.
audibility, 3.2.4.18., 3.2.4.21.
audible alert and alarm signals, 3.2.4.17.
central alarm and control facility, 3.2.6.7.
central vacuum shutdown, 3.2.4.13.
continuity, 3.2.4.2.
design, 9.10.18.3.
and door hold-open devices, 3.1.8.14.
electrical supervision, 3.2.4.9.
emergency power supply, 3.2.7.8.
fire detectors, 3.2.4.4., 3.2.4.10.
fire separations for, 3.6.2.8.
installation, 3.2.4.1., 3.2.4.5., 9.10.18.3.
manual stations, 3.2.4.16.
requirements, 9.10.18.
residential firewarning systems, 3.2.4.21., 9.10.19.8.
signal devices, 3.2.4.18.
signals to fire department, 3.2.4.7.
silencing, 3.2.4.6.
single stage systems, 3.2.4.3., 3.2.4.4., 3.2.4.7.
smoke alarms, 3.2.4.20.
smoke detectors, 3.2.4.11., 3.2.4.12., 9.10.18.,
9.10.18.5.
sprinkler systems, 3.2.4.8.
testing, 3.2.4.5.
two-stage systems, 3.2.4.3., 3.2.4.4., 3.2.4.7.
types, 3.2.4.3.
vacuum cleaning systems, 9.10.18.7.
visible
signal devices, 3.2.4.19.
voice communication systems, 3.2.4.22.
Index
Index British Columbia Building Code 2018
waterflow trigger, 3.2.5.14.
Fire blocks
(see also Fire stops)
in concealed spaces, 3.1.11., 9.10.16.
definition, 1.4.1.2.[A]
in eave overhangs, 3.2.3.16.
in floor assemblies, 3.1.11.5.
in mansard and gambrel roofs, 3.1.11.5., 9.10.16.1.
materials, 3.1.11.7., 9.10.16.3.
in noncombustible construction, 3.1.5.2., 3.1.11.3.
pipes and ducts in, 9.10.16.4.
in roof assemblies, 3.1.11.5., 3.1.11.7.
in walls/wall assemblies, 3.1.11.2., 9.10.16.2.
Fire chambers, 9.22.4.
Fire compartments
annunciators, 3.2.4.8.
basements, 3.2.1.5.
combustible sprinkler piping, 3.2.5.13.
definition, 1.4.1.2.[A]
exits, 3.2.3.13.
exposing building face area, 3.2.3.2.
unprotected openings, 3.2.3.1.
wall exposed to another wall, 3.2.3.14.
Fire curtains, 3.3.2.14.
Fire dampers
(see also Dampers)
access, 3.1.8.10.
as closures, 3.1.8.5.
definition, 1.4.1.2.[A]
in ducts, 9.10.13.13.
in fire separations, 3.1.8.7.
in HVAC systems, 6.9.2.1.
installation, 3.1.8.10.
leakage rates, 3.1.8.4.
in non-loadbearing walls, 9.24.3.7.
penetrating fire separations, 9.10.9.6.
waived, 3.1.8.8.
Fire department
access routes, 3.2.5.4., 3.2.5.6.
limiting distance, 9.10.15.3.
signals to, 3.2.4.7., 3.2.4.9., 3.2.6.7.
Fire department connections on buildings, 3.2.5.5.,
3.2.5.9., 3.2.5.15.
Fire detectors, 1.4.1.2.[A], 3.2.4.4., 3.2.4.10.
Fire escapes
access, 3.4.7.3.
balconies, 3.4.7.3.
closures, 3.4.7.4.
construction, 3.4.7.2.
dwelling units, 3.4.7.3.
existing buildings, 3.4.7.1.
guards, 3.4.7.6.
handrails, 3.4.7.6.
headroom, 3.4.7.5.
landings, 3.4.7.7.
loads on, 4.1.5.3.
as means of egress, 3.4.1.4., 9.9.2.3.
protection of, 3.4.7.4.
scope of Code, 3.4.7.1.
stairs, 3.4.6.8., 3.4.7.5.
Fire extinguishers, 3.2.5.16., 9.10.20.4., 9.10.21.8.
Fire extinguishing systems, industrial occupancies,
3.3.5.2.
Firefighters, 3.2.6.2., 3.2.6.5., 3.2.8.7.
Firefighting (see Access for firefighting)
Firefighting services (see Fire department)
Fire hose cabinets, 3.2.5.11.
Fire hose nozzles, 3.2.5.11.
Fire hose stations, 3.2.5.11., 9.10.21.9.
Fire load, 1.4.1.2.[A], 3.2.2.89., 3.2.3.11.
Fireplaces
airtightness, 9.36.2.9.
chimneys, 9.21.2.5., 9.21.2.6.
clearances, 9.22.9.
combustion air, 9.22.1.4.
concrete materials, 9.22.1.2.
continuity of insulation, 9.36.2.5.
dampers, 9.22.6.1.
design and installation, 6.9.4.2.
factory-built, 9.22.8.
fire chamber, 9.22.4.
footings, 9.22.1.3.
hearth, 9.22.5.
housing and small buildings, 9.22., 9.33.5.4.
inserts, 9.22.10.
liners (see Liners, fireplace)
masonry materials, 9.22.1.2.
protection against depressurization, 9.32.3.8.
smoke chambers, 9.22.7.
walls, 9.22.3.
Fire protection
air-supported structures, 3.1.6.
building classification, 3.1.2.
combustible construction, 3.1.4.
commissioning of life safety and fire protection
systems, 9.10.1.2.
components, 2.2.3.[C], 3.1.1.4.
construction camps, 9.10.21.
Index
British Columbia Building Code 2018 Index
cooktops, 9.10.22.
crawl spaces, 9.18.7.
dwelling units, 9.10.
electric ranges, 9.10.22.
electrical conductors, 3.2.7.10.
exceptions, 3.2.2.3.
exits, 9.9.4.
fire-resistance ratings, 3.1.7.
fire safety plan, 1.1.4.
gas ranges, 9.10.22.
limiting distance and spatial separation between
buildings, 3.2.3.1.
multiple occupancy requirements, 3.1.3.
noncombustible construction, 3.1.5.
ovens, 9.10.22.
penetrations in fire separations and fire-rated
assemblies, 3.1.9.1.
propane ranges, 9.10.22.
structural, 3.2.2.3.
structural members, 3.2.3.9.
tents, 3.1.6.
testing of integrated fire protection and life safety
systems, 9.10.1.2.
tests, 3.2.9.1.
Fire-protection rating
of closures, 3.1.8.4., 3.1.8.5.
definition, 1.4.1.2.[A]
of doors, 3.1.8.12.
exceptions, 9.10.13.2., 9.10.13.5., 9.10.13.7.
of fire dampers, 3.1.8.7.
tests, 3.1.8.4., 9.10.3.1.
Fire protection systems, 3.2.5.17., 9.10.18., 9.10.20.5.
Fire pumps, 3.2.4.9., 3.2.5.9., 3.2.5.18., 9.10.1.3.
Fire-resistance ratings
about, 9.10.3.
arena-type building roof assemblies, 3.2.2.17.
ceilings, 9.10.3.3.
definition, 1.4.1.2.[A]
determination of, 3.1.7.1., 9.10.3.1.
doors, 5.3.1.2.
exemptions, 9.10.8., 9.10.8.11., 9.10.14.
exits, 9.9.4.2.
exposing building face, 3.2.3.7.
fire separations, 3.1.7.3.
firewalls, 3.1.7.3., 3.1.10.2., 9.10.3.3.
floors and floor assemblies, 3.1.7.3., 3.2.1.4.,
9.10.3.1., 9.10.3.3., 9.10.8.
grease duct enclosures, 3.6.3.5.
membrane ceilings, 9.10.3.4.
minimum, 3.1.7.4.
relation to occupancy and height, 9.10.8.
roofs, 9.10.8.
separation of suites, 3.3.1.1., 9.10.9.13., 9.10.9.14.
steel framing, 9.24.2.4., 9.24.3.2.
supporting construction, 3.1.7.5., 9.10.8.3.
test methods, 9.10.3.1.
vertical fire separations, 9.10.3.3.
walls, 9.10.3.3.
walls, exterior, 3.1.7.2., 3.1.7.3., 3.2.3.7., 3.2.3.11.,
9.10.3.1., 9.10.3.3., 9.10.14.5., 9.10.15.5.
walls, interior, 9.10.3.1., 9.10.3.3.
walls, loadbearing, 3.1.7.5., 9.10.8.3.
windows, 5.3.1.2.
Fire-retardant-treated wood
in assembly occupancy (Group A, Division 2),
3.2.2.25.
in assembly occupancy (Group A, Division 3),
3.2.2.32.
in business and personal services occupancy
(Group D), 3.2.2.60.
in combustible construction, 3.1.4.5., 3.1.4.8.
for decorative cladding, 3.1.5.24.
definition, 1.4.1.2.[A]
in low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.83.
in medium-hazard industrial occupancy (Group
F, Division 2), 3.2.2.76.
in mercantile occupancy (Group E), 3.2.2.66.
in noncombustible construction, 3.1.5.5., 3.1.5.12.,
3.1.13.8.
in roof systems, 3.1.14.1.
Fire safety
and building size, 3.2.1.1., 9.10.8.
construction sites, 8.1.1.1.
demolition sites, 8.1.1.1.
in HVAC systems and equipment, 6.9.1.1., 9.33.6.
and occupancy, 9.10.8.
self-service storage buildings, 3.9.2.
tests, 3.2.9.1.
Fire separations
airtightness of windows and doors in, 5.4.1.2.
barrier-free floor areas, 3.3.1.7.
boarding and lodging houses, 9.10.9.14.
on building face, 3.2.3.2.
business and personal services occupancy, 3.3.1.1.
care, treatment or detention occupancy, 3.3.3.1.
closures in, 3.1.8.1., 3.1.8.4., 3.1.8.5., 9.10.13.
in combustible construction, 3.1.8.2.
Index
Index British Columbia Building Code 2018
construction camps, 9.10.21.2.
containment in basements, 3.2.1.5.
continuity, 3.1.8.1., 3.1.8.3., 9.10.9.2., 9.10.11.2.
crawl spaces, 3.2.2.9., 9.10.9.4.
definition, 1.4.1.2.[A]
and door hold-open devices, 3.1.8.14.
and door self-closing devices, 3.1.8.13.
dumbwaiters, 3.5.3.2.
dwelling units, 3.3.4.2., 9.10.9.11., 9.10.9.12.,
9.10.9.13.
elevator machine rooms, 3.5.3.3.
elevators, 3.2.6.5., 3.5.3.1.
exits, 3.4.4.1., 9.9.4.
fire dampers in, 3.1.8.7.
fire-resistance rating, 3.1.7.3.
firewalls, 3.1.10.1.
floor assemblies, 3.3.4.2.
floors over basements, 3.2.1.4.
garages, 9.10.4.3., 9.10.9.16., 9.10.9.17.
grease duct enclosures, 3.6.3.5.
horizontal, 3.1.8.8.
in horizontal service spaces, 3.1.8.3.
horizontal service spaces, 3.6.4.2., 9.10.9.10.
industrial occupancy (group F), 3.3.5.1., 9.10.9.11.,
9.10.9.12., 9.10.9.16., 9.10.9.17.
integrity, 9.10.9.3.
interconnected floor spaces, 9.10.9.5.
interior walls, 9.10.12.3.
laboratory ventilation enclosures, 3.3.1.20.
libraries, 3.3.2.13.
and major occupancy, 9.10.9.11., 9.10.9.16.,
9.10.9.17.
meeting of two exterior walls, 9.10.12.3.
mercantile occupancy (group E), 3.3.1.1.
mezzanines, 3.2.8.1.
and multiple occupancies, 3.1.3.1., 9.10.9.11.,
9.10.10.
between openings, 3.2.3.17.
openings in, 3.1.8.1., 3.1.8.6., 3.1.8.17., 3.2.8.2.,
9.10.13., 9.24.3.7.
openings protected by glass blocks or wired glass,
3.1.8.16.
operating, recovery and delivery rooms, 3.3.3.6.
protected floor spaces, 3.2.8.5.
public corridors, 3.3.1.4., 9.10.9.15.
rating, 9.10.3.
repair garages, 3.3.5.5.
residential occupancy (Group C), 3.2.2.47., 3.3.4.2.,
9.10.9.11., 9.10.9.12., 9.10.9.14.
roof-top enclosures, 3.2.2.14.
between rooms and spaces within buildings, 9.10.9.
secondary suites, 9.10.9.4., 9.10.9.14., 9.10.9.15.,
9.10.10.4., 9.10.11.2., 9.10.12.3.
self-service storage buildings, 3.9.3.1.
self-storage warehouses, 3.3.5.9.
service penetrations, 3.1.9.2. - 3.1.9.6., 9.10.9.6.
service rooms, 3.6.2.1., 9.10.8.5., 9.10.10.
soffit protection, 9.10.12.4.
steel framing, 9.24.2.4., 9.24.3.7.
storage of dangerous goods, 3.3.6.2.
storage garages, 3.2.1.2., 3.3.4.2., 3.3.5.6., 3.3.5.7.
storage rooms, 3.3.4.3., 9.10.10.6.
storeys below ground, 3.2.2.15.
suites, 3.3.1.1., 3.3.4.2., 9.10.9.13., 9.10.9.14.
temperature rise and area limits, 3.1.8.19.
theatre stages, 3.3.2.14.
thermal breaks in windows and doors in, 5.3.1.2.
twenty-minute closures, 3.1.8.12.
vehicular passageways, 3.2.3.18.
vertical, 3.1.8.8., 3.1.8.9.
vertical service spaces, 3.6.3.1.
in vertical shafts, 3.1.8.3.
vestibules, 3.2.8.4.
walkways, 3.2.3.19., 3.2.3.20.
wall exposed to another wall, 3.2.3.14.
watertightness of windows and doors in, 5.9.2.3.
between zones in hospitals or nursing homes,
3.3.3.5.
Fire stop flaps, 1.4.1.2.[A], 3.6.4.3., 9.10.13.14.
Fire stops
(see also Fire blocks)
definition, 1.4.1.2.[A]
in noncombustible construction, 3.1.5.2.
pipes and ducts in, 3.1.9.5., 9.10.9.6., 9.33.6.6.
and service penetrations, 3.1.9.1., 9.10.9.7.
Firewalls
combustible projections, 3.1.10.7.
construction, 9.10.11.
continuity, 3.1.10.3.
continuity of insulation, 9.36.2.5.
definition, 1.4.1.2.[A]
exemptions, 9.10.11.2.
exterior walls meeting at, 3.1.10.6.
and fire alarm systems, 3.2.4.2.
fire-resistance rating, 3.1.7.3., 3.1.10.2., 9.10.3.3.,
9.10.11.3.
maximum openings in, 3.1.10.5.
mezzanines, 3.2.8.1.
Index
British Columbia Building Code 2018 Index
parapets, 3.1.10.4.
party walls as, 9.10.11.1.
penetrations in, 3.1.9.1.
separating buildings, 1.3.3.4.[A]
structural stability, 3.1.10.1., 4.1.5.17.
support of, 3.1.10.1., 4.1.5.17.
First storey, 1.4.1.2.[A], 3.2.2.15., 3.2.5.1., 3.2.8.2.
Fixed seats, 3.3.2.4.
Fixed seats, bench type without arms, 3.3.2.8.
Flags, for directing traffic, 8.2.4.2.
Flame-spread rating
bathrooms, 3.1.13.3., 9.10.17.11.
business and personal services occupancy, 9.10.17.
combustible insulation, 9.10.17.10., 9.10.17.12.
combustible piping, 3.1.5.19.
combustible skylights, 9.10.17.9.
corridors, 9.10.17.2., 9.10.17.5.
crawl spaces, 9.18.7.1.
definition, 1.4.1.2.[A]
diffusers and grilles, 9.33.6.10.
doors, 3.1.13.2., 9.7.2.2., 9.10.17.1.
ducts, linings and coverings, 9.10.17.12., 9.33.6.4.
elevator cars, 3.1.13.7., 3.1.13.11.
exits, 3.1.13.2., 3.1.13.7., 3.1.13.8., 9.10.17.2.
exterior exit passageways, 3.1.13.10., 9.10.17.4.
fire-retardant-treated wood, 3.1.4.5.
firewalls, 9.10.11.3.
foamed plastic insulation, 3.1.5.15., 9.10.17.10.
glazing, 3.1.5.4., 3.1.13.2., 9.10.17., 9.10.17.1.,
9.10.17.6., 9.10.17.9.
gypsum board, 9.29.5.2.
high buildings, 3.1.13.7.
industrial occupancy, 9.10.17.
insulation, 5.9.1.1., 9.25.2.2.
insulation in concealed spaces, 9.10.17.
insulation in noncombustible construction,
3.1.5.14., 3.1.5.15.
interior finishes, 3.1.5.12., 9.10.17.
light diffusers and lenses, 3.1.13.4., 9.10.17.6.,
9.10.17.8.
lobbies, 3.1.13.2., 9.10.17.3.
mercantile occupancy, 9.10.17.
public corridors, 3.1.13.6., 9.10.17.
residential occupancy, 3.1.13.3., 9.10.17.
service rooms, 3.1.13.7., 9.10.17.
skylights, 3.1.5.4., 3.1.13.2., 9.7.2.2., 9.10.17.,
9.10.17.1., 9.10.17.6., 9.10.17.9.
tests, 3.1.12.1., 9.10.3.2.
vehicular passageways, 3.1.13.2.
ventilated laboratory enclosures, 6.3.4.4.
vestibules, 3.1.13.7.
windows, 9.7.2.2.
Flammable gases (see Combustible gases)
Flammable liquids
definition, 1.4.1.2.[A]
door thresholds, 3.3.1.13., 3.4.6.1.
piping for, in trench, 6.9.1.2.
storage, 3.3.2.16., 3.3.4.3., 3.3.6.2.
storage and dispensing rooms, 3.3.6.4.
Flashing, chimney
caps, 9.21.4.6.
junctions with other materials, 9.21.4.10.
Flashing, doors, 9.7.6.2.
Flashing, roof
built-up-roofing at cant strips, 9.26.11.10.
built-up-roofing to masonry, 9.26.4.6.
built-up-roofing to other than masonry, 9.26.4.7.
at intersections, 9.26.4.
materials, 9.26.2.1., 9.26.4.2., 9.26.4.3.
purpose, 9.26.1.2.
sealing and drainage, 5.6.2.1.
shingles to masonry, 9.26.4.4.
shingles to other than masonry, 9.26.4.5.
valley, 9.26.4.3.
Flashing, skylights, 9.7.6.2.
Flashing, wall
cavity walls, 9.20.13.5., 9.20.13.6.
fastening, 9.20.13.2.
installation, 9.20.13.3., 9.27.3.8.
masonry veneer, 9.20.13.6.
masonry walls, 9.20.13.
materials, 9.20.13.1., 9.27.3.7.
sealing and drainage, 5.6.2.1.
stucco, 9.28.1.5.
Flashing, windows, 9.7.6.2., 9.20.13.3., 9.20.13.4.
Flash point, 1.4.1.2.[A]
Flat roofs, wind loads, 4.1.7.6.
Flight, 1.4.1.2.[A] (see also Stairs)
Floor areas
accessible design, 9.5.2.
accessible path of travel, 3.3.1.7.
care, treatment or detention occupancy, 3.3.3.1.
combination rooms, 9.5.1.2.
definition, 1.4.1.2.[A]
emergency access, 3.4.6.18.
general requirements, 3.3.1.
secondary suites, 9.1.2.1.
self-service storage buildings, 3.9.3.
Index
Index British Columbia Building Code 2018
separation of suites, 3.3.1.1.
termination, 9.10.12.1.
Flooring
ceramic tile, 9.23.15.5., 9.30.6.
finish, 9.30.1.4.
in hazardous materials storage area, 3.3.6.7.
housing and small buildings, 9.30.
parquet, 9.30.4.
supports, 9.30.1.3.
underlay, 9.30.2.
water-resistant membranes, 9.30.1.2.
wood strip, 9.23.15.5., 9.30.3.
Floor joists, support of, 9.15.5.1.
Floor numbers
Arabic numerals, 3.4.6.19., 9.9.11.5.
elevator hoistways, 3.5.4.2.
exits, 3.4.6.19., 9.9.11.5.
Floors
acting as diaphragms, 4.1.8.15., 4.1.8.18.
air barrier systems, 9.25.3.
anchorage, 9.20.11.1.
cantilevered, 9.23.9.9.
combustible elements in noncombustible
construction, 3.1.5.10.
concrete topping, 9.23.4.4.
construction camps, 9.10.21.3.
dampproofing, 9.13.2.1.
drains, 9.31.4.3.
fire-resistance ratings, 3.1.7.3., 9.10.3.1., 9.10.8.1.,
9.10.8.8.
as fire separations, 9.10.9.4.
framing, 9.23.4.
garages, 9.35.2.2.
in heavy timber construction, 3.1.4.7.
joists, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.9.
loads due to use of, 4.1.5.
loads on, 9.23.1.1., 9.23.4.1., 9.23.4.2., 9.23.4.4.
subfloors, 9.23.15.
supports, 3.2.1.4., 9.30.1.3.
thermal insulation, 9.25.1.1.
vibrations, 4.1.3.6.
Floors on ground, thermal resistance, 9.36.2.8.
Floors-on-ground
concrete, 9.16.4.
dampproofing, 9.13.2.1., 9.13.2.6.
drainage, 9.16.3.
hydrostatic uplift, 9.16.3.2.
in dwelling units, 9.16.1.3.
in housing and small buildings, 9.16.
material beneath, 9.16.2.
soil gas control, 9.13.4., 9.25.3.6.
Flue collars, 1.4.1.2.[A]
Flue pipes, 1.4.1.2.[A], 9.21.1.2.
Flues, chimney
connections, 9.21.2.2.
definition, 1.4.1.2.[A]
dimensions, 9.21.2.4., 9.21.2.5., 9.21.4.4.
fireplace, 9.21.2.5.
inclination, 9.21.2.3.
masonry and concrete, 9.21.
oval, 9.21.2.6.
rectangular, 9.21.2.5.
round, 9.21.2.5.
slope, 9.21.2.3.
standard for, 9.21.2.
Foamed plastic
dampproofing, 9.13.2.5.
insulation, 3.1.5.14., 3.1.5.15., 3.6.3.2., 5.3.1.3.,
9.10.17.10., 9.25.2.2., 9.33.6.4.
in noncombustible construction, 3.1.5.2., 3.1.5.7.,
3.1.5.14., 3.1.5.15.
protection of, 3.1.4.2., 9.10.17.10.
vapour barrier, 9.25.4.2.
Footbridges, 4.1.5.3.
Footings
area for column spacing, 9.15.3.3., 9.15.3.4., 9.15.3.7.
chimneys, 9.15.3.1., 9.21.4.3.
design, 9.4.4.1.
dimensions, 9.15.3.
drainage, 9.14.
fireplaces, 9.15.3.1., 9.22.1.3.
granular drainage layer, 9.14.4.
housing and small buildings, 9.15.
non-loadbearing masonry walls, 9.15.3.6.
projections, 9.15.3.8.
stepped, 9.15.3.9.
thickness, 9.15.3.8.
trenches, 9.12.4.1.
width, 9.15.3.3., 9.15.3.4., 9.15.3.5., 9.15.3.6., 9.15.3.8.
Forced-air furnace, 1.4.1.2.[A]
Forced-air heating systems
(see also Ducts; Heating systems and equipment)
coupled with heat recovery ventilators, 9.32.3.12.
ventilation systems coupled with, 9.32.3.4.
ventilation systems not coupled with, 9.32.3.5.
Formwork, 4.1.1.3.
Foundations
adfreezing, 4.2.4.4.
Index
British Columbia Building Code 2018 Index
backfilling, 4.2.5.8., 9.12.3.
capacity in weaker soil or rock, 9.4.4.2.
of concrete, 4.2.3.5., 9.3.1.6., 9.3.1.7., 9.15.1.1.,
9.15.2., 9.15.4.
of concrete block, 9.15.4.2.
dampproofing, 9.13.2.
deep, 1.4.1.2.[A], 4.2.7.
definition, 1.4.1.2.[A]
for deformation-resistant buildings, 9.12.2.2.,
9.15.1.3.
depth, 4.2.4.4., 9.12.2.
design, 4.2.4., 9.4.4., 9.15.1.1.
drainage, 9.14.2., 9.35.3.3.
drawings and specifications, 2.2.4.6.[C], 2.2.4.7.[C],
4.2.2.2.
dynamic loading, 4.2.4.7.
earthquake design, 4.1.8.16., 4.1.8.17.
eccentric loading, 4.2.4.6.
equivalent approaches to design, 4.1.1.5.
excavations, 4.2.5., 9.12.
extension above ground, 9.15.4.6.
on filled ground, 4.2.4.13.
of flat insulating concrete forms, 9.15.1.1., 9.15.3.3.,
9.15.4., 9.15.4.5.
footing size, 9.15.3.
frost action, 4.2.4.4., 9.12.2.2.
on frozen ground, 9.12.1.3.
for garages and carports, 9.35.3.
granular drainage layer, 9.14.4.
and groundwater level, 4.2.4.9., 9.4.4.3.
for housing and small buildings, 9.15.
hydrostatic pressure, 4.2.4.8., 9.16.3.2.
insulation, 9.25.2.2., 9.25.2.3.
lateral support, 9.15.4.2., 9.15.4.3., 9.15.4.4., 9.15.4.5.
limit states design, 4.2.4.1.
loads, 4.2.4.1.
of masonry, 4.2.3.3., 4.2.3.4., 9.15.1.1., 9.15.2.,
9.15.4., 9.15.4.10.
materials, 4.2.3., 9.15.2.
movement, 4.2.4.1., 9.12.2.2.
on organic soils, 9.12.1.1.
on permafrost, 4.2.4.10., 9.15.1.2.
of permanent form material, 9.15.4.1.
pier type, 9.15.2.3.
protection from surface water, 5.7.1.1.
review, 4.2.2.3.
on rock, 9.15.3.1., 9.15.3.2.
shallow, 1.4.1.2.[A], 4.2.6.
site stability, 4.1.8.17.
on sloping ground, 4.2.4.5.
special, 4.2.8.
stairs with, 9.12.2.2.
of steel, 4.2.3.7.
structural design, 4.2.4.14.
subsurface investigation, 4.2.2.1., 4.2.4.2.
supporting floor joists, 9.15.5.1.
on swelling and shrinking soils, 4.2.4.11., 9.4.4.4.
thermal resistance, 9.36.2.8.
thickness, 9.15.4.2., 9.15.4.7.
trenches beneath, 9.12.4.
vertical reinforcement, 9.15.4.6.
walls, 9.4.4.6., 9.15.4., 9.36.2.8.
of wood, 4.2.3.1., 4.2.3.2., 9.15.1.1., 9.15.2.4.
for wood-frame construction, 9.15.1.1., 9.15.2.4.
Foundation units
definition, 1.4.1.2.[A]
drawing alterations, 2.2.4.7.[C]
Framing
anchorage, 9.23.6.
ceiling, 9.23.14.
drilling, 9.23.5.1.
maximum spans, 9.23.4.
notching, 9.23.5.2.
over openings, 9.23.12.
roof, 9.23.14.
sheet steel stud, 9.24.
supported on masonry or concrete, 9.20.8.
trusses, 9.23.14.11.
wood-frame construction, 9.23.
Freezers, walk-in, 3.1.4.2., 3.1.5.7., 9.10.17.10.
Freezing, protection from (see Protection from
freezing)
Frost action
(see also Frost penetration, depth; Protection from
freezing)
definition, 1.4.1.2.[A]
floors-on-ground, 9.16.2.2.
soil under foundations, 9.4.4.4.
Frost penetration, depth, 1.1.3.2., 9.12.2.2.
Fuel dispensing facilities, 3.3.5.8., 9.10.1.3.
Fuel supply, shut-off valves, 3.2.7.7.
Functional statements
application, 3.1.[A]
list of, 3.2.1.[A]
Furnaces
capacity, 9.33.3.1., 9.33.5.1.
clearances, 6.2.1.5., 9.33.5.2., 9.33.6.8.
definition, 1.4.1.2.[A]
Index
Index British Columbia Building Code 2018
forced-air, 1.4.1.2.[A]
installation, 6.2.1.6., 9.33.5.2.
performance requirements, 9.36.3.10.
plenums, 9.33.6.6., 9.33.6.7., 9.33.6.8.
ventilation, 9.32.3.4.
Furring
cladding, 9.27.5.3.
dimensions, 9.29.3.1.
fastening, 9.29.3.2.
interior finish, 9.29.3.
metal thickness, 9.24.1.3.
nailing, 9.29.3.2.
stucco lath, 9.28.4.4.
G
Gable roofs
snow and rain loads, 4.1.6.9.
wind loads, 4.1.7.6.
Galvanized sheet metal, 9.3.3.2.
Gambrel roof
fire blocks, 9.10.16.1.
venting, 9.19.1.4.
Garages
(see also Carports)
clear height, 3.3.5.4.
columns, 9.35.4.2., 9.35.4.3.
detached, 9.10.14.4., 9.10.14.5., 9.10.15.4., 9.10.15.5.,
9.35.3.3.
doors, 9.10.13.15., 9.36.2.9.
for dwelling units, 9.7.5.2., 9.10.9.16., 9.35.
exhaust discharge into, 6.3.2.10.
floors, 9.3.1.6., 9.35.2.2.
foundations, 9.35.3.
guards and guardrails, 9.8.8.4.
interconnection of ducting, 6.3.2.7., 9.33.6.7.
lighting, 9.34.2.6.
loads on floor or roof, 4.1.5.3.
open-air, 9.10.14.4.
pressure, 6.3.1.4.
repair (see Repair garages)
resistance to forced entry, 9.7.5.2.
storage (see Storage garages)
ventilation, 3.3.5.4., 6.3.1.4., 9.32.1.1.
walls, 9.35.4.1., 9.35.4.3.
Gas-burning equipment, installation standard,
6.2.1.5., 9.33.5.2.
Gases, hazardous, 6.9.1.2.
Gas mains, under buildings, 3.2.3.21.
Gas vents
definition, 1.4.1.2.[A]
materials and installation, 9.33.10.1.
sealing around, 9.25.3.3.
Girders, in heavy timber construction, 3.1.4.7.
Glass
(see also Transparent panels)
area limits, maximum, 9.6.1.3.
design, 9.6.1.3.
doors, 3.3.1.19., 9.6.1.4., 9.7.5.2.
earthquake design, 4.1.8.18.
in exits, 3.4.1.8.
in fire separations, 3.2.3.13., 5.3.1.2., 9.10.13.5.
in guards, 9.8.8.7.
panels, 3.3.1.19.
public areas, 9.6.1.4., 9.7.5.
safety (see Safety glass)
sidelights, 9.6.1.4.
standards for, 5.9.1.1., 9.6.1.2., 9.6.1.3., 9.6.1.4.,
9.7.5.2., 9.8.8.7.
structural design basis, 4.3.6.
structural strength, 9.6.1.3.
thermal breaks, 5.9.2.4., 9.7.3.3.
thickness, 9.6.1.3.
types of, 9.6.1.4.
wired (see Wired glass)
Glass block assemblies, thermal characteristics,
9.36.2.7.
Glass blocks
area limits, 3.1.8.18.
as closures, 3.1.8.5., 9.10.13.7.
excluding, and temperature limits, 3.1.8.19.
in exits, 9.9.4.3. - 9.9.4.6.
in fire separations, 3.1.8.16.
not to be used as closures, 3.2.3.5.
not in fireplaces or chimneys, 9.20.2.3.
protection of exit facilities, 3.2.3.13.
reinforcing, 9.20.9.6.
in unprotected openings, 3.2.3.12., 9.10.14.4.
Glass-reinforced polyester roofing, 9.26.14.1.
Glazed architectural structures (see Fenestration)
Glazed openings, 9.10.15., 9.10.15.2., 9.10.15.4.
Glazing
in doors, 9.7.1.1.
exit restrictions, 3.4.1.10.
in fire separations, 3.1.8.16.
in noncombustible construction, 3.1.5.4.
in public areas, 9.8.8.1.
in unprotected openings, 3.2.3.12.
Index
British Columbia Building Code 2018 Index
wired glass, 3.1.8.16., 3.1.8.18., 3.1.8.19., 3.2.3.5.
Glued-laminated timber
beams, 9.23.4.1., 9.23.4.2., 9.23.4.4.
flooring, 3.1.4.7.
lintels, 9.23.12.3.
Grab bars
bathtubs, 3.7.2.9., 3.8.3.17.
loads on, 9.31.2.3.
showers, 3.8.3.16.
universal washrooms, 3.8.3.12.
washrooms, 3.7.2.8., 3.8.3.11.
Grade, 1.4.1.2.[A], 3.2.3.18., 3.2.5.1.
Grading, site
backfill, 9.8.10.3., 9.12.3.2.
environmental separation, 5.1.2.1.
excavations, 9.14.4.3.
surface drainage, 9.14.6.
water control, 5.7.1.1., 9.16.3., 9.18.5.
Granular material
beneath floors-on-ground, 9.16.1.1., 9.16.2.1.
beneath footings and foundations, 9.14.2.1., 9.14.4.
Grease duct enclosures, 3.6.3.5.
Ground cover
crawl spaces, heated, 9.18.6.2.
crawl spaces, unheated, 9.18.6.1.
warm-air plenums, 9.18.7.1.
Groundwater
around excavations, 4.2.5.5.
definition, 1.4.1.2.[A]
and foundations, 2.2.4.6.[C], 4.2.2.1., 4.2.2.4.,
4.2.4.3., 4.2.4.9.
level, 1.4.1.2.[A], 4.2.4.9., 9.4.4.3., 9.14.5.3., 9.15.3.4.,
9.16.3.1.
protection from, 5.7.3.
Group A occupancy (see Assembly occupancy)
Group B occupancy (see Care, treatment or detention
occupancy)
Group C occupancy (see Residential occupancy)
Group D occupancy (see Business and personal
services occupancy)
Group E occupancy (see Mercantile occupancy)
Group F occupancy (see Industrial occupancy)
Grout, 9.20.3.2.
Guards (devices)
balconies and decks, 4.1.7.5., 9.8.8.1., 9.8.8.3.
cane-detectable, on doors, 3.8.3.6.
definition, 1.4.1.2.[A]
doorways, 9.8.8.1.
dwelling units, 3.3.4.7., 9.8.1.
exits, 3.4.6.6.
fire escapes, 3.4.7.6.
fixed seats, 3.3.2.9.
garages, 3.3.5.4., 9.8.8.4.
glass, 9.8.8.7.
height, 3.3.1.18., 3.3.5.4., 3.4.6.6., 9.8.8.3.
housing and small buildings, 9.8.8.
industrial occupancies, 3.3.5.10.
landings, 3.4.6.6., 9.8.8.3.
loads, 3.3.5.4., 4.1.5.14., 9.8.8.2., 9.8.8.4.
means of egress, 9.9.1.1.
to not facilitate climbing, 9.8.8.6.
openable windows, 3.3.4.8.
openings through, 3.3.1.18., 3.4.6.6., 3.4.7.6., 9.8.8.5.
porches, 9.8.8.3.
as protection for vehicles, 4.1.5.15.
ramps, 3.4.6.6., 3.8.3.5., 9.8.8.1., 9.8.8.4.
secondary suites, 9.8.1.
stairs, 3.4.6.6.
where required, 9.8.8.1.
windows in public areas, 3.3.1.19.
windows in residential occupancy, 9.8.8.1.
Guards (human), for danger zones, 8.2.1.4.
Gypsum board
application standard, 9.29.5.1.
on exposing building face, 3.2.3.7.
fasteners for, 9.29.5.5.
fastening, 9.29.5.8., 9.29.5.9.
as fire separation in exit, 9.9.4.2.
as fire stop, 3.1.11.7.
installation, 9.29.5.3., 9.29.5.8., 9.29.5.9.
as interior finish, 9.29.5.
material standard, 9.29.5.2.
in noncombustible construction, 3.1.5.13.
standards, 9.10.9.2.
as thermal barrier, 3.1.5.14., 3.1.5.15.
as wall sheathing, 9.23.17.2., 9.23.17.3.
Gypsum lath, 9.29.4.1.
H
Hallways (see Corridors)
Handrails
in aisles with steps, 3.3.2.10.
attachment, 9.8.7.7.
continuity, 3.4.6.5., 9.8.7.2.
design, 9.8.7.7.
in dwelling units, 3.3.4.7., 9.8.1., 9.8.7.1.
ergonomic design, 9.8.7.5.
Index
Index British Columbia Building Code 2018
graspability, 3.4.6.5., 9.8.7.5.
height, 3.4.6.5., 9.8.7.4.
in housing and small buildings, 9.8.7.
loads, 3.4.6.5., 4.1.5.14., 9.8.7.7.
in means of egress, 9.9.1.1.
projecting into means of egress, 3.4.3.3.
projecting into stair or ramp, 9.8.7.6.
for ramps, 3.4.6.5., 3.8.3.5., 9.8.7.
in secondary suites, 9.8.1., 9.8.7.
for stairs, 3.4.6.5., 3.4.6.9., 9.8.7.
termination, 9.8.7.3.
Hardboard
as cladding, 9.27.2.4., 9.27.3.6., 9.27.5.
fastening, 9.29.7.3.
as insulating finish, 9.25.5.1.
as interior finish, 9.29.7.
material standards, 5.9.1.1., 9.27.9.1., 9.29.7.1.
nailing, 9.29.7.3.
as siding, 9.27.2.4., 9.27.3.6., 9.27.9.
thickness, 9.3.2.7., 9.29.7.2.
as underlay, 9.30.2.2.
as wall sheathing, 9.25.5.1.
Hardware for doors
access to exit, 3.3.1.13.
automatic locking devices, 3.3.4.5.
bolts, 9.7.5.2.
closers in barrier-free path of travel, 3.8.3.6.
closures, 3.1.8.5.
door release devices, 3.3.1.13., 3.3.2.7., 3.4.6.16.,
9.9.6.7.
height, 3.4.6.16.
hinges, 9.7.5.2.
hold-open devices, 3.1.8.14., 9.10.13.11.
locks and latches, 3.3.1.13., 3.4.6.16., 3.4.6.17.,
3.4.6.18., 9.7.5.2., 9.9.6.7., 9.9.6.8., 9.10.13.9.
power operators, 3.8.3.6.
self-closing devices, 3.1.8.13., 3.4.6.13., 9.9.6.7.,
9.10.13.10., 9.10.13.15.
strikeplates, 9.7.5.2.
on transparent doors and panels, 3.3.1.19.
universal washrooms, 3.8.3.12.
Hatchways, 9.19.2.1., 9.25.3.3.
Hazardous substances
explosion venting, 3.3.1.20.
fire detectors, 3.2.4.10.
fire protection, 9.10.1.3.
heat and smoke detection, 9.10.18.4.
prohibited in basements, 3.3.5.3.
safety within floor areas, 3.3.1.2.
storage, 9.10.1.3.
Headroom clearance
access to exits, 9.9.3.4.
doorways, 3.4.3.4., 9.5.5.1.
exits, 3.4.3.4., 9.9.3.4.
stairways, 3.4.3.4., 9.8.2.2.
Hearths, fireplace
extensions, 9.22.5.1.
standard for, 9.22.5.
support, 9.22.5.2.
Heat detectors, 1.4.1.2.[A], 9.10.18.3., 9.10.18.4.
Heating appliances
capacity, 9.33.3.1., 9.33.5.1.
design, 6.4.1.2., 9.33.5.3.
installation, 6.2.1.6.
installation standards, 6.2.1.5., 9.33.5.2., 9.33.5.3.
location, 6.4.1.1.
Heating coils, service water heaters, 9.31.6.5.
Heating systems and equipment
access, 6.2.1.6., 6.8.1.1., 9.33.4.4.
asbestos in, 6.2.1.7., 9.33.4.8.
capacity, 9.33.3.1., 9.33.5.1.
cleaning, 6.2.1.6., 9.33.4.4.
continuity of insulation, 9.36.3.5.
design, 6.2.1.1., 6.4.1.2., 9.33.1.1., 9.33.4.1., 9.33.5.3.
drawings and specifications, 2.2.6.2.[C]
energy efficiency, 9.36.
fire safety characteristics, 6.9.1.1., 9.33.6.2. - 9.33.6.4.
installation, 6.2.1., 9.33.1.1., 9.33.4.1.
installation standards, 6.2.1.1., 6.2.1.5., 9.33.5.2.,
9.33.5.3.
location, 6.4.1.1.
performance requirements, 9.36.3.10.
protection from freezing, 6.2.1.6., 9.33.4.5.
in residential buildings, 9.33.2.1.
solid-fuel-burning, 6.2.1.5., 9.33.5.3.
structural movement, 4.1.8.18., 6.2.1.4., 9.33.4.7.
system pressure, 6.2.1.3., 9.33.4.6.
temperature controls, 9.33.4.3., 9.36.3.6.
Heating, ventilating and air-conditioning (HVAC)
systems and equipment
access, 6.2.1.1., 6.2.1.6., 6.8.1.1., 9.33.4.4.
air intakes and outlet dampers, 9.36.3.3.
airtightness, 9.36.2.10.
application of Code, 6
asbestos in, 6.2.1.7., 9.33.4.8.
cleaning, 6.2.1.6., 9.33.4.4.
contaminant transfer prevention, 9.33.4.8.
continuity of insulation, 9.36.3.5.
Index
British Columbia Building Code 2018 Index
design, 6.2., 6.2.1.1., 6.4.1.2., 9.32.3.2., 9.33.1.1.,
9.33.4.1., 9.33.5.3.
drawings and specifications, 2.2.6.2.[C]
energy efficiency, 9.36., 9.36.3.
energy performance calculations, 9.36.5.7.
energy performance modeling, 9.36.5.11., 9.36.5.15.
equipment and ducts, 9.36.3.2.
fire safety characteristics, 6.9.1.1., 9.33.6.2. - 9.33.6.4.
heat recovery, 9.36.3.8., 9.36.3.9.
humidification, 6.3.2.16., 9.36.3.7.
installation, 6.2., 9.32.3.2., 9.33.1.1., 9.33.4.1.
installation standards, 6.2.1.1., 6.2.1.5., 9.33.5.2.,
9.33.5.3.
outdoor design conditions, 6.2.1.2.
performance requirements, 9.36.3.10.
piping, 9.36.3.4.
protection from freezing, 6.2.1.6., 9.33.4.5.
structural movement, 4.1.8.18., 6.2.1.4., 9.33.4.7.
system pressure, 6.2.1.3., 9.33.4.6.
temperature controls, 9.36.3.6.
Heat pumps, 9.36.3.6., 9.36.3.10.
Heat recovery
indoor pools and hot tubs, 9.36.3.8.
ventilation systems, 9.36.3.9.
Heat recovery ventilators
balancing, 9.32.3.4.
capacity, 6.3.1.5., 9.32.3.10.
condensate, 9.32.3.12.
installation, 6.3.1.5., 9.32.3.12.
standards for, 9.32.3.10.
Heat transfer
application of Code, 5.1.1.1.
calculations and analyses, 5.2.1.3.
exterior insulation finish systems, 5.9.4.1.
performance in doors, windows and skylights,
5.9.2.4., 9.7.3.2.
performance in other fenestration assemblies,
5.9.3.3.
and required thermal insulation, 9.25.2.1.
thermal resistance of assemblies, 5.3.1., 5.3.1.2.
Heavy timber construction
assembly occupancy (Group A, Division 1),
3.2.2.21.
assembly occupancy (Group A, Division 3),
3.2.2.30., 3.2.2.31.
assembly occupancy (Group A, Division 4),
3.2.2.35.
construction of exposing building faces, 9.10.15.5.
definition, 1.4.1.2.[A]
dimensions, 3.1.4.7.
exposing building faces, 9.10.14.5.
fire resistance, 9.10.6.2.
fire safety requirements, 3.1.4.7.
flame-spread rating, 3.1.13.8.
high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.71.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.87., 3.2.2.88.
roofs, 3.2.2.16.
structural members, 3.2.3.9.
walkways, 3.2.3.19.
when permissible, 3.1.4.6., 3.2.2.16.
Height
access to exit, 3.3.1.8., 9.9.3.4.
between landings, 9.8.3.3., 9.8.4.4., 9.8.5.5.
ceilings, 9.5.3.
doorways, 9.5.5., 9.9.6.2.
exits, 9.9.3.4., 9.9.6.2.
guards, 9.8.8.3.
handrails, 9.8.7.4.
mezzanines, 9.5.3.2.
over landings, 9.8.6.4.
over ramps, 9.8.5.3.
over stairs, 9.8.2.2.
rooms and spaces, 9.5.3.1.
storage garages, 9.5.3.3., 9.9.3.4.
Helicopter landing areas, 3.2.4.7., 3.2.4.16., 4.1.5.13.,
9.23.16.7.
Heritage buildings, 1.1.1.1.
High buildings
additional requirements, 3.2.6.1.
anchorage, 9.23.6.1.
central alarm and control facility, 3.2.6.7.
construction site protection of public, 8.2.3.2.
interior finishes, 3.1.13.7.
smoke control system testing, 3.2.6.9.
smoke movement limits, 3.2.6.2.
vertical transportation in, 3.5.1.1.
voice communication systems, 3.2.6.8.
wind loads, 4.1.7.3.
High-hazard industrial occupancy (Group F, Division 1)
building classification, 3.1.2.1.
definition, 1.4.1.2.[A]
egress doorways, 3.3.1.5.
fire alarm systems, 3.2.4.1., 3.2.4.3.
fire protection, 3.2.2.70. - 3.2.2.73.
occupant load, 3.1.17.1.
safety within floor areas, 3.3.1.2.
Index
Index British Columbia Building Code 2018
Hipped roofs, wind loads, 4.1.7.6.
Hold-open devices, 3.1.8.14., 9.10.13.11.
Horizontal exits
balconies, 3.4.6.10.
bridges, 3.4.6.10.
definition, 1.4.1.2.[A]
hose station beside, 3.2.5.11.
and other types of exits, 3.4.1.4.
restricted use, 3.4.1.6.
vestibules, 3.4.6.10.
width, 3.4.6.10.
Horizontal service spaces
access, 3.6.4.5.
application of Code, 3.6.1.1., 3.6.4.1.
definition, 1.4.1.2.[A]
fire blocks in, 3.1.11.5.
above fire separations, 3.1.8.3., 9.10.9.10.
fire separations for, 3.6.4.2.
sprinkler systems, 3.2.5.14.
Hose connections, 3.2.5.9., 3.2.5.10.
Hospitals, 3.1.8.13., 3.3.3.5., 3.4.1.6.
Hot tubs, heat recovery, 9.36.3.8.
Hot water supply, 9.31.4.2.
Housing and small buildings
(see also Dwelling units)
air leakage, 9.25.
cladding, 9.27.
columns, 9.17.
concrete materials, 9.3.1.
condensation control, 9.25.
crawl spaces, 9.18.
dampproofing, 9.13.
design of areas and spaces, 9.5.
drainage, 9.14.
electrical facilities, 9.34.
energy efficiency, 9.36.
excavations, 9.12.
fire protection, 9.10.
fireplaces, 9.22.
flooring, 9.30.
floors-on-ground, 9.16.
footings and foundations, 9.15.
glass, 9.6.
heat transfer, 9.25.
heating and air-conditioning, 9.33.
interior wall and ceiling finishes, 9.29.
lumber and wood products for, 9.3.2.
masonry and concrete chimneys, 9.21.
masonry and insulating concrete walls, 9.20.
materials, systems and equipment, 9.3.
means of egress, 9.9.
plumbing facilities, 9.31.
roof spaces, 9.19.
roofing, 9.26.
sheet steel stud wall framing, 9.24.
soil gas control, 9.13.
sound control, 9.11.
stairs, ramps, handrails and guards, 9.8.
structural requirements, 9.4.
stucco, 9.28.
ventilation, 9.32.
waterproofing, 9.13.
windows, doors and skylights, 9.7.
wood-frame construction, 9.23.
Humidification, 6.3.2.16., 9.36.3.7.
HVAC (see Heating, ventilating and air-conditioning
(HVAC) systems and equipment)
Hydrants, 3.2.5.5., 3.2.5.15.
Hydronic heating
design, 9.33.4.1.
installation, 9.33.4.2.
Hydrostatic pressure, 4.2.4.8., 5.7.2., 9.13.3.1., 9.16.3.2.
I
Ice, accumulation, 4.1.6.2., 4.1.6.15., 4.1.7.11., 5.3.1.2.,
5.6.2.2.
Impeded egress zones
definition, 1.4.1.2.[A]
door release hardware, 3.4.6.16.
doors and door hardware, 3.3.1.13.
fire alarm systems, 3.2.4.1.
fire annunciators, 3.2.4.8.
sliding doors, 3.4.6.14.
sprinkler system requirements, 3.2.2.19.
Importance categories for buildings, 4.1.2.1.
Importance factors
earthquake loads, 4.1.8.5.
snow loads, 4.1.6.2.
wind loads, 4.1.7.3.
Incinerator rooms, 3.6.2.4., 9.10.10.5.
Indirect service water heaters (see Service water
heaters)
Indoor design temperature, 5.2.1.2., 5.3.1.2., 5.5.1.2.,
9.33.3.1.
Indoor pools
heat recovery, 9.36.3.8.
temperature controls, 9.36.4.6.
Index
British Columbia Building Code 2018 Index
water heaters, 9.36.4.2.
Industrial occupancy (Group F)
(see also High-hazard industrial occupancy;
Low-hazard industrial occupancy;
Medium-hazard industrial occupancy)
classification, 9.10.2.
definition, 1.4.1.2.[A]
door thresholds, rooms with flammable liquids,
3.3.1.13., 3.4.6.1.
exposing building face, 9.10.14.5.
fire alarm systems, 9.10.18.
fire-resistance rating, 9.10.8.
fire separations, 9.10.9.11., 9.10.9.12.
flame-spread rating, 9.10.17.
guards, 3.3.5.10., 9.8.8.5.
ramps and stairways, 3.3.1.14., 3.4.6.7., 3.4.6.8.
self-service storage buildings, 3.9.1.3.
washrooms, 3.7.2.
Information required for proposed work, 2.2.2.1.[C]
Institutional occupancy (see Care, treatment or
detention occupancy)
Insulation
attic or roof spaces, 9.25.2.4.
basements, 9.25.2.2.
combustible, in noncombustible construction,
3.1.5.14., 3.1.5.15.
concealed spaces, 3.1.11.2.
continuity of, 9.36.2.5.
crawl spaces, 9.25.2.2., 9.25.2.3.
ducts, 3.1.5.18., 6.3.2.5., 9.32.3.11., 9.33.6.4.
environmental separation, 5.1.1.1.
exposure to exterior space on ground, 5.1.2.1.
foamed plastic, 3.1.5.14., 3.1.5.15., 5.3.1.3.,
9.10.17.10., 9.25.2.2., 9.33.6.4.
foundations, 9.12.2.2., 9.25.2.2., 9.25.2.3.
installation, 5.3.1.3., 9.25.2.3., 9.27.3.4.
loose-fill, 9.25.2.4.
materials, 9.25.2.2.
material standards, 5.9.1.1., 9.25.2.2.
pipes, 3.1.5.18., 6.5.1.1., 9.33.8.2., 9.33.8.4.
plenums, 9.33.6.4.
properties, 9.25.5.1.
protection of, 9.10.17.10., 9.25.2.3.
requirement for, 5.3.1.1., 9.25.2.1.
roofs, 9.25.2.2.
slabs-on-ground, 9.25.2.3.
spray-applied, 5.3.1.3., 9.25.2.5.
supported by gypsum board, 9.29.5.4.
thermal, 9.25.2.
thermal resistance, 5.3.1.
walls, 9.25.2.4.
wall sheathing, 9.23.17.2., 9.23.17.3., 9.27.3.4.
wires and cables, 3.1.5.21.
Interconnected floor spaces, 1.4.1.2.[A], 3.2.3.2.,
3.2.8.2., 3.2.8.8., 9.10.9.5.
Interconnection of duct systems, 6.3.2.7., 6.3.2.10.,
9.33.6.7.
Interior finishes
for braced wall panels, 9.23.13.6.
ceilings, 9.23.9.4., 9.29.
dampproofing, 9.13.2.5.
fastening to steel studs, 9.24.1.4.
flame-spread limits, 9.10.17.
flame-spread rating, 3.1.13.2.
floors, 9.30.
gypsum board, 9.29.5.
hardboard, 9.29.7.
in noncombustible construction, 3.1.5.12.
insulating fibreboard, 9.29.8.
masonry walls, 9.20.13.9.
materials, 3.1.13.1.
OSB, 9.29.9.
particle board, 9.29.9.
plastering, 9.29.4.
plywood, 9.29.6.
public corridor ceilings, 3.1.13.6.
on steel studs, 9.24.1.5.
support, 9.23.10.5., 9.24.3.4.
tiles, 9.29.10.
underground walkways, 3.1.13.9.
waferboard, 9.29.9.
walls, 9.29.
waterproof, 9.29.2.
J
Janitors’ rooms, 3.2.4.10., 3.3.1.21., 9.10.18.4.
Joints and connections for ducts, 9.33.6.2., 9.33.6.3.,
9.33.6.6., 9.33.6.7.
Joists
bearing, 9.23.9.1.
cantilevered, 9.23.9.9.
ceilings, 9.23.14.1., 9.23.14.7.
continuity, 9.23.14.1.
dimensions, 9.23.4.1., 9.23.14.7., 9.23.14.10.
end bearing length, 9.23.14.3.
floors, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.9.
framing around openings, 9.23.14.2.
Index
Index British Columbia Building Code 2018
header, 9.23.9.5., 9.23.9.7.
lumber grade, 9.3.2.1.
nailing, 9.23.3.4., 9.23.9.3., 9.23.14.9.
preservative treatment, 9.23.2.2., 9.23.2.3.
roofs, 9.23.4.2., 9.23.4.5., 9.23.14.1., 9.23.14.7.,
9.23.14.9.
spans, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.4.5.,
9.23.14.7., 9.23.14.10.
strapping, bridging and furring, 9.23.9.4.
support, 9.23.14.7.
supported on beams, 9.23.9.2.
supported on masonry or concrete, 9.20.8.2.,
9.20.8.3., 9.21.5.3., 9.23.2.2., 9.23.2.3.
supporting walls, 9.23.9.8.
tail, 9.23.9.7.
trimmer, 9.23.9.6.
wood, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.4.5.
Junction boxes, electrical, 3.1.5.2., 9.10.9.6.
K
Kitchens
commercial cooking equipment, 3.3.1.2., 6.3.1.7.,
9.10.1.4., 9.10.13.13.
emergency lighting, 3.2.7.3.
exhaust ducts, 3.1.8.8., 3.1.8.9., 6.3.2.10., 9.32.3.11.
exhaust fans, 9.32.3.3., 9.32.3.7.
exhaust outlets, 6.3.2.10.
grease duct enclosures, 3.6.3.5.
loads on floor or roof, 4.1.5.3.
L
Laboratories
enclosure exhaust ventilation, 3.3.1.20., 6.3.4.3.
live loads on floor or roof, 4.1.5.3.
ventilated enclosure construction, 6.3.4.4.
Landings
barrier-free, 3.8.3.5.
configurations, 9.8.6.3.
dimensions, 3.4.3.4., 3.4.6.4., 9.8.6.3.
at doorways, 3.4.3.3., 3.4.6.3., 9.8.6.2., 9.8.6.3.,
9.9.6.1.
fire escapes, 3.4.7.7.
guards, 3.4.6.6., 9.8.8.
height between, 3.4.6.3., 9.8.3.3., 9.8.4.4., 9.8.5.5.
height over, 9.8.6.4.
in housing and small buildings, 9.8.6.
omitted, 3.4.6.3.
openings in, 3.4.6.4.
as part of exit, 9.8.1.3.
on ramps, 9.8.6.
slip-resistance, 3.4.6.1., 9.8.9.6.
on stairs, 9.8.6.
Lateral loads
anchorage, 9.23.6.1.
braced wall bands, 9.23.13.4., 9.23.13.5.
braced wall panels, 9.23.13.5., 9.23.13.6.
bracing considerations, 9.23.13.7.
bracing requirements, 9.23.13., 9.23.13.1.
fasteners for framing, 9.23.3.4.
fasteners for sheathing and subfloors, 9.23.3.5.
floor joists supporting walls, 9.23.9.8.
lumber roof sheathing, 9.23.16.5.
materials, 9.23.13.6.
particleboard, OSB or waferboard finishes, 9.29.9.3.
plywood finish, 9.29.6.3.
roof sheathing, required, 9.23.16.1.
spacing of nails in gypsum board, 9.29.5.8.
spacing of screws in gypsum board, 9.29.5.9.
Lath, plaster
gypsum, 9.29.4.1.
metal, 9.29.4.1.
Lath, stucco
attachment to sheathing, 9.27.5.1.
dimensions, 9.28.4.3.
fastening, 9.27.5.7., 9.27.7.5., 9.28.4.6.
installation, 9.28.4.2., 9.28.4.5., 9.28.4.6.
materials, 9.28.4.1., 9.28.4.3.
nailing, 9.27.5., 9.28.4.6.
self-furring, 9.28.4.4.
standard for, 9.28.4.
stapling, 9.27.5., 9.28.4.6.
uses, 9.28.1.2.
Lattice structures, ice loading, 4.1.6.15.
Laundry-drying equipment, 9.32.1.3.
Laundry rooms, 3.2.4.10., 3.3.1.22., 9.10.18.4.
Lavatories, 3.7.2.3., 3.8.2.8., 3.8.3.15.
Libraries, 3.3.2.13., 4.1.5.3.
Licensed beverage establishments
access to exit, 3.3.1.17.
principal entrances, 3.4.2.6.
Life safety systems, 3.2.9.1., 9.10.1.2.
Light diffusers and lenses, 3.1.13.4., 9.10.17.6.,
9.10.17.8.
Lighting
basements, 9.34.2.3., 9.34.2.4.
elements, 3.1.13.1., 9.10.17.6., 9.10.17.8.
emergency, 3.2.7.3., 3.2.7.4., 9.9.12.3., 9.34.2.7., 9.34.3.
Index
British Columbia Building Code 2018 Index
entrances, 9.34.2.1.
exits, 3.2.7.1.
fixtures, recessed, 3.2.7.2., 9.34.1.4.
garages and carports, 9.34.2.6.
levels, 9.9.12.2., 9.9.12.3.
levels, minimum, 3.2.7.1.
means of egress, 9.9.12.
outlets for, 3.2.7.1., 9.34.2.
public corridors, 3.2.7.1., 9.9.12.2., 9.9.12.3.
public and service areas, 9.34.2.7.
stairways, 9.34.2.3.
Lightning protection systems, 3.6.1.3.
Limiting distance
between construction camp buildings, 9.10.21.5.
definition, 1.4.1.2.[A]
exposing building face, 3.2.3.5., 3.2.3.6., 3.2.3.7.,
9.10.14.5., 9.10.15.5.
exterior walls, 9.10.3.3.
fire department response time, 3.2.3.1.
and firefighting services, 9.10.15.3.
fire-resistance rating exception, 3.1.7.2.
less than 1.2 m, 3.2.3.5.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.3.11.
maximum concentrated area, 3.2.3.1.
spatial separation between buildings, 3.2.3.1.,
9.10.14.3., 9.10.15.
unprotected openings, 3.2.3.1., 3.2.3.10.
wall exposed to another wall, 3.2.3.14.
Limit states design
application, 4.1.3.
dead load, 4.1.3.2.
definition of terms, 4.1.3.1.
effect of factored loads, 4.1.3.2.
fatigue check, 4.1.3.3.
importance factors, 4.1.6.2., 4.1.8.5.
load factors, 4.1.3.2.
resistance, 4.1.3.2.
serviceability check, 4.1.3.4.
strength and stability check, 4.1.3.2.
Linen chutes, 3.6.3.3., 9.10.1.3.
Liners, chimney
clay, 9.21.3.3.
clearances, 9.21.3.8.
concrete, 9.21.3.5.
definition, 1.4.1.2.[A]
extensions, 9.21.3.10.
firebrick, 9.21.3.4.
installation, 9.21.3.7.
joints, 9.21.3.2.
materials, 9.21.3.1.
metal, 9.21.3.6.
mortar, 9.21.3.9.
separation, 9.21.4.9.
standard for, 9.21.3.
Liners, fireplace
firebrick, 9.22.2.2.
standard for, 9.22.2.
steel, 9.22.2.3.
wall thickness, 9.22.3.
Linings
for ducts and plenums, 3.1.5.18., 6.3.2.5., 9.33.6.4.
for radiators and convectors, 6.4.3.1., 9.33.7.1.
Lintels
dimensions, 9.23.12.3.
fireplaces, 9.22.1.2.
nailing, 9.23.12.3.
spans, 9.23.12.3.
steel, 3.2.2.3., 9.10.7.1., 9.20.5.2., 9.22.1.2.
supporting masonry over openings, 9.20.5.2.
wood, 9.23.12.
Liquids, combustible (see Combustible liquids)
Liquids, flammable (see Flammable liquids)
Liquids, hazardous, 6.9.1.2.
Live loads (see Loads)
Loadbearing, definition, 1.4.1.2.[A]
Loads
in attics, 9.4.2.4.
bearing pressure for soil or rock, 9.4.4.1.
climatic, 1.1.3., 5.2.1.1.
combinations, 4.1.3.2.
concentrated, 4.1.5.9.
dead, 1.4.1.2.[A], 4.1.3.2., 4.1.4., 9.4.3.1.
deflections under, 4.1.3.5., 9.4.3.
design requirement, 4.1.1.3.
in dining areas, 4.1.5.3., 4.1.5.6.
due to crane, 4.1.3.2., 4.1.5.11.
due to earthquakes, 4.1.3.2., 4.1.8.
due to ice, 4.1.6.15.
due to partitions, 4.1.4.1.
due to resonance, 4.1.3.6.
due to snow and rain, 4.1.6., 4.1.6.4., 9.4.2.2., 9.4.2.3.
due to sway forces, 4.1.5.10.
due to use and occupancy, 4.1.5.
during construction, 4.1.1.3.
eccentric, on foundations, 4.2.4.6.
environmental, 5.1.4.1., 5.2.1., 5.2.1.3.
on exterior areas, 4.1.5.5.
Index
Index British Columbia Building Code 2018
on firewalls, 4.1.5.17.
on floors, 4.1.5.3., 9.23.1.1., 9.23.4.1., 9.23.4.2.,
9.23.4.4.
on foundations, 4.2.4.1., 9.4.4.6.
full and partial, 4.1.5.3.
on grab bars, 3.7.2.8., 9.31.2.3.
on guards, 3.3.5.4., 4.1.5.14., 9.8.8.2., 9.8.8.4.
on handrails, 3.4.6.5., 4.1.5.14., 9.8.7.7.
and helipads, 4.1.5.13.
hydrostatic, 4.2.4.8., 9.13.3.1., 9.16.3.2.
impact of machinery and equipment, 4.1.5.11.
lateral (see Lateral loads)
limit states, 4.1.3.
live, 1.4.1.2.[A], 4.1.5.
with more than one occupancy, 4.1.5.7.
not specified, 4.1.2.2.
permanent, 4.1.3.2.
on ramps, 9.8.9.1.
on residential balconies, 4.1.5.3., 9.4.2.3.
on retaining walls, 9.4.4.5., 9.4.4.6.
specified, 4.1.2., 9.4.2.
on stairs, 9.8.9.1.
structural, 4.1., 9.4.
structural, on environmental separators, 5.1.4.1.,
5.2.2.
and structural strength, 5.2.2.
variation with tributary area, 4.1.5.8.
on vehicle guardrails, 4.1.5.15.
vibration, 4.1.3.6.
on walls acting as guards, 4.1.5.16.
wind (see Wind load)
Lobbies, 3.4.4.2., 9.9.8.5., 9.10.17.3.
(see also Vestibules)
Locking devices
automatic, 3.3.4.5.
contained use area, 3.3.1.13.
electromagnetic, 3.3.1.13., 3.4.6.16., 3.4.6.18., 9.9.6.7.
impeded egress zone, 3.3.1.13.
principal entrances, 9.9.6.7.
Locks, deadbolt, 9.7.5.2.
Low buildings, wind loads, 4.1.7.5., 4.1.7.6.
Lowest exit level, 3.2.6.2., 3.4.3.2., 3.4.5.2., 9.9.11.4.
Low fire load, 3.2.2.89., 3.2.3.11.
Low-hazard industrial occupancy (Group F, Division 3)
building classification, 3.1.2.1.
definition, 1.4.1.2.[A]
fire alarm systems, 3.2.4.1., 9.10.18.
fire protection, 3.2.2.80. - 3.2.2.90., 3.2.3.11.
fire safety within floor areas, 3.3.1., 3.3.5.
occupant load, 3.1.17.1.
Lumber
dimensions, 9.3.2.6.
fire stops, 3.1.11.7.
grades, 9.3.2.1., 9.3.2.2., 9.3.2.3.
for housing and small buildings, 9.3.2.
moisture content, 9.3.2.5.
protection from termites and decay, 9.3.2.9.
sheathing, 9.23.16.5.
structural uses, 9.3.2.9.
undersized, 9.3.2.8.
M
Main entrances (see Principal entrances)
Major occupancy
and building classification, 3.1.2.1., 9.10.2.
definition, 1.4.1.2.[A]
occupancy combination prohibitions, 3.1.3.2.
Major occupancy and fire safety requirements
building area determination, 3.2.2.5.
exceptions, 3.2.2.8.
fire separations, 3.1.3.1.
multiple occupancies, 3.1.3., 3.2.2.4., 3.2.2.6.,
9.10.2., 9.10.9.11., 9.10.9.16., 9.10.9.17.
superimposed occupancies, 3.2.2.7.
Makeup air
and depressurization protection, 9.32.3.8.
fans, 9.32.3.10.
requirements, 6.3.2.8.
for subfloor depressurization, 9.13.4.3.
Mansard roofs
fire stopping, 3.1.11.5.
sheathing, 9.23.17.6.
venting, 9.19.1.4.
Manual stations, fire alarm systems, 3.2.4.4., 3.2.4.16.
Manufactured buildings,
application of code, 1.1.1.1.[A]
foundations, 9.12.2.2., 9.15.1.3.
Marquees, 3.1.5.24., 3.1.16.1., 3.2.2.3.
Masonry
bonding, 9.20.9., 9.20.11.2.
chases and recesses, 9.20.7.
chimneys, 1.4.1.2.[A], 6.3.3.2., 9.21., 9.33.10.3.
cold weather requirements, 9.20.14.
columns, 9.17.5.
corbelling, 9.20.12.
dampproofing, 9.13.2.3.
earthquake reinforcement, 9.20.1.2., 9.20.15.
Index
British Columbia Building Code 2018 Index
exposure to weather, 9.20.2.6.
flashing, 9.20.13., 9.26.4.4., 9.26.4.6.
flues, 9.21.
foundations, 4.2.3.3., 4.2.3.4., 9.15.1.1., 9.15.2.,
9.15.4., 9.15.4.10.
grout, 9.20.3.2.
installation, 5.6.1.2., 9.15.2.2., 9.15.2.3., 9.20.
joints, 9.20.4., 9.20.9.1.
lateral support, 9.20.10.
material standards, 5.6.1.2., 5.9.1.1., 9.15.2.2.,
9.17.5.1.
mortar, 9.20.3.1., 9.20.3.2.
parapet walls, 9.20.6.5.
for pilasters, 9.15.5.3.
solid, 1.4.1.2.[A]
structural design basis, 4.3.2.1.
stucco on, 9.28.1.3.
supporting beams, 9.15.5.2.
supporting floor joists, 9.15.5.1.
support of loads, 9.20.5., 9.20.8.
as thermal barrier, 3.1.5.14., 3.1.5.15.
ties, 9.20.9.5.
tying, 9.20.9., 9.20.11.2.
units, 1.4.1.2.[A], 9.20.2., 9.20.2.1.
used brick, 9.20.2.2.
veneer, 9.20.6.4., 9.20.8.5., 9.20.9.5., 9.20.12.3.
walls, 9.20.
weep holes, 5.6.2.1., 9.20.13.5., 9.20.13.6., 9.20.13.8.
Mastics, 3.1.5.2.
Materials
braced wall panels, 9.23.13.6.
characteristics, 1.2.2.1.[A]
cladding, hardboard, factory-finished, 9.27.9.1.
cladding, lumber, 9.27.6.1.
cladding, OSB and waferboard, 9.27.10.1.
cladding, plywood, 9.27.8.1.
cladding, strip steel, 9.27.11.1.
cladding, vinyl, 9.27.12.1.
columns, unit masonry, 9.17.5.1.
columns, wood, 9.17.4.2.
combustible, in noncombustible construction,
9.10.6.
concrete, 9.3.1.
dampproofing, 9.13.2.2.
design requirements, 4.3.
drainage tile and pipe, 9.14.3.1.
ducts, 6.3.2.3., 9.32.3.11., 9.33.6.2.
eave protection, 9.26.5.2.
exterior insulation finish systems, 9.27.13.
fibreboard, insulating, 9.29.8.1.
fire blocks, 9.10.16.3.
fire stops, 3.1.9.1., 3.1.11.7.
flashing, 9.20.13.1., 9.26.4.2., 9.27.3.7.
foundations, 4.2.3.
glass, 9.6.1.2.
granular, beneath floors, 9.16.2.
gypsum products, 9.29.5.2.
hardboard, 9.29.7.1.
for housing and small buildings, 9.30.
lumber and wood products, 9.3.2.
metal, 9.3.3.
particleboard finish, 9.29.9.1.
pipes for heating and cooling systems, 6.7.1.1.,
9.33.8.1.
review of, 2.2.7.4.[C]
roofing, 9.26.2.1.
roof sheathing, 9.23.16.2.
sealants, 9.27.4.2.
shingles and shakes, 9.27.7.1.
standards, 1.5.[A], 5.9.1.1.
steel studs and runners, 9.24.1.2.
storage, 1.2.2.2.[A], 9.10.1.3.
subflooring, 9.23.15.2.
testing, 4.1.1.5.
thermal characteristics, 9.36.2.2.
underlay, panel-type, 9.30.2.2.
used, 1.2.2.3.[A]
waterproofing, 9.13.3.2., 9.29.2.2.
Materials, appliances, systems and equipment
characteristics, 1.2.2.1.[A]
storage, 1.2.2.2.[A]
used, 1.2.2.3.[A]
Means of egress
(see also Exits)
from air-supported structures, 3.1.6.1.
from care, treatment or detention occupancy,
3.3.3.3.
definition, 1.4.1.2.[A]
dimensions, 9.9.3.
through doors and windows in dwelling units,
9.7.2.2.
from dwelling units, 3.3.4.4., 9.9.9.
exterior passageways as, 3.2.2.12.
and fire hose cabinets, 3.2.5.11.
within floor areas, 3.3.1.3.
from housing and small buildings, 9.9.
lighting of, 9.9.12.2.
obstructions in, 3.3.1.23., 3.4.3.3., 9.9.5., 9.9.5.5., 9.9.11.2.
Index
Index British Columbia Building Code 2018
from outdoor places of assembly, 3.3.2.11.
from secondary suites, 9.9.9.
sliding doors in, 3.3.1.12.
from tents, 3.1.6.1.
transparent panels or doors in, 3.3.1.19., 9.6.1.4.
with two separate exits, 9.9.9.2.
Measurement, rooms and spaces, 9.5.1.1.
Mechanical systems and equipment (see
Heating, ventilating and air-conditioning
(HVAC) systems and equipment)
Mechanical ventilation (see Ventilation)
Medical gas piping, 3.7.3.1., 9.31.1.1.
Medium-hazard industrial occupancy (Group F,
Division 2)
ammonium nitrate storage, 3.3.6.6.
building classification, 3.1.2.1.
definition, 1.4.1.2.[A]
fire alarm systems, 3.2.4.1., 9.10.18.
fire protection, 3.2.2.74. - 3.2.2.79.
fire safety within floor areas, 3.3.1., 3.3.5.
occupant load, 3.1.17.1.
Mercantile occupancy (Group E)
classification, 3.1.2.1., 9.10.2.
definition, 1.4.1.2.[A]
exit stairs, 9.9.4.7.
exposing building face, 9.10.14.5.
fire alarm systems, 3.2.4.1., 9.10.18.
fire protection, 3.2.2.64. - 3.2.2.69.
fire-resistance rating, 9.10.8.
fire safety within floor areas, 3.3.1.
flame-spread rating, 9.10.17.
occupant load, 3.1.17.1.
security, 3.4.6.17.
Metal
cladding, 5.6.1., 5.9.1.1., 9.27.3.6., 9.27.5.6., 9.27.11.
for housing and small buildings, 9.3.3.
galvanized sheet, 9.3.3.2.
roof deck assembly, 3.1.14.2.
sheet thickness, 9.3.3.1.
siding, 5.6.1., 5.9.1.1., 9.27.3.6., 9.27.5.6., 9.27.11.
Mezzanines
application of requirements to exterior
passageways, 3.2.2.12.
assembly occupancy (Group A, Division 1), 3.2.2.20.
assembly occupancy (Group A, Division 2), 3.2.2.23.
assembly occupancy (Group A, Division 3), 3.2.2.29.
and building height, 3.2.1.1., 9.10.4.1., 9.10.4.2.
business and personal services occupancy (Group D), 3.2.2.55.
care, treatment or detention occupancy (Group B,
Division 1), 3.2.2.36., 3.2.2.37.
care, treatment or detention occupancy (Group B,
Division 2), 3.2.2.38. - 3.2.2.41.
care, treatment or detention occupancy (Group B,
Division 3), 3.2.2.42. - 3.2.2.46.
ceiling height, 9.5.3.2.
definition, 1.4.1.2.[A]
fire-resistance rating, 9.10.8.6., 9.10.9.4.
fire separations, 3.2.1.6., 3.2.8.1., 9.10.12.1.
guards, 3.3.1.18., 9.8.8.1.
high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.70.
loads on floor or roof, 4.1.5.3., 4.1.5.4.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.80.
means of egress, 3.4.2.2., 9.9.8.6.
medium-hazard industrial occupancy (Group F,
Division 2), 3.2.2.74.
mercantile occupancy (Group E), 3.2.2.64.
occupant load, 3.1.17.1.
openings in floor assemblies, 3.2.8.2.
residential occupancy (Group C), 3.2.2.47.
termination, 9.10.12.1.
Micro-organisms, minimizing growth of, 6.3.1.6.,
6.3.2.15.
Mild climate indicator, 9.25.4.2., 9.25.5.1.
Millwork, combustible, 3.1.5.9.
Mirrors
in exits, 9.9.5.6.
in washrooms, 3.8.3.15.
Misters, 6.3.2.16.
Mobile home parks, sanitary facilities, 3.7.2.4.
Moisture
diffusion, 5.1.1.1., 5.5.1.2.
flooring resistant to, 9.30.1.2.
protection against, application of Code, 9.13.1.1.
resistant backing for wall tile, 9.29.10.4.
transfer, 5.1.1.1., 5.2.1.3., 5.5.1.2.
Moisture index, 9.27.2.2.
Mortar
aggregate for, 5.9.1.1., 9.20.3.1., 9.20.3.2., 9.29.10.2.
as base for ceramic wall tile, 9.29.10.2.
cold weather requirements, 9.20.14.
joints, 9.20.4.
material standards, 9.20.3.1.
mixes, 9.20.3.2.
standard for, 9.20.3.
uses, 9.20.3.2.
Index
British Columbia Building Code 2018 Index
Movement, differential
columns, 9.17.2.2.
decks and other accessible platforms, 9.12.2.2.,
9.23.6.2.
elements in environmental separation, 5.1.4.1.,
5.2.2.1.
metal and vinyl cladding, 9.27.5.6.
Moving walks, 3.2.8.2., 3.8.2.3., 3.8.2.4., 9.8.1.4.
Multiple occupancies
and building classification, 9.10.2.
building size and construction requirements,
3.2.2.4.
fire separations, 3.1.3.
requirements decided by most restricted
occupancy, 3.2.2.6.
separation of repair garages, 9.10.9.17.
separation of residential occupancies, 9.10.9.11.
separation of storage garages, 9.10.9.16.
N
Nailing
bracing, 9.23.10.2.
built-up beams, 9.23.8.3.
cladding, 9.27.5., 9.27.7.3.
columns, 9.17.4.2.
fibreboard finish, 9.29.8.3.
framing, 9.23.3.4.
furring, 9.29.3.2.
gypsum board, 9.29.5.5., 9.29.5.8.
hardboard finish, 9.29.7.3.
joists, 9.23.9.2., 9.23.9.3., 9.23.14.9.
lintels, 9.23.12., 9.23.12.3.
OSB finish, 9.29.9.3.
particleboard finish, 9.29.9.3.
plywood finish, 9.29.6.3.
prevention of splitting, 9.23.3.3.
rafters, 9.23.14.4.
roofing, 9.26.2.3.
runners, 9.24.3.1.
shakes, 9.27.7.3.
sheathing, 9.23.3.5.
shingles, 9.26.7.4., 9.26.7.6., 9.26.8.5., 9.27.7.3.
siding, 9.27.5., 9.27.7.3.
stucco, 9.28.3.2.
subflooring, 9.23.3.5., 9.23.15.6.
underlay, 9.30.2.3.
waferboard finish, 9.29.9.3.
wall plates, 9.23.11.3.
wood-frame construction, 9.23.3.
wood shingles and shakes, 9.26.9.5., 9.26.10.4.
wood strip flooring, 9.30.3.3.
Nailing and supporting elements
fire blocks required, 3.1.11.3.
in noncombustible construction, 3.1.5.8.
Nails
for cladding, 9.27.5., 9.27.5.4., 9.27.7.3.
diameters, 9.23.3.1.
dimensions, 9.23.3.5., 9.26.2.3., 9.27.5.4.
for fibreboard finish, 9.29.8.3.
for gypsum board, 9.29.5.6.
length, 9.23.3.2.
for OSB finish, 9.29.9.3.
for particleboard finish, 9.29.9.3.
for roofing, 9.23.3.5., 9.26.2.3.
for shingles, 9.26.7.4.
standard for, 9.23.3.1., 9.26.2.3., 9.29.5.6.
for underlay, 9.30.2.3.
for waferboard finish, 9.29.9.3.
Noise, protection from, 5.8., 9.32.3.10.
Noncombustible cladding, 3.2.3.7., 3.2.3.9.
Noncombustible construction
assembly occupancy (Group A, Division 1),
3.2.2.20., 3.2.2.21.
assembly occupancy (Group A, Division 2),
3.2.2.23., 3.2.2.24.
assembly occupancy (Group A, Division 3),
3.2.2.29.
assembly occupancy (Group A, Division 4),
3.2.2.35.
business and personal services occupancy (Group
D), 3.2.2.55.
care, treatment or detention occupancy (Group B,
Division 1), 3.2.2.36., 3.2.2.37.
care, treatment or detention occupancy (Group B,
Division 2), 3.2.2.38. - 3.2.2.41.
care, treatment or detention occupancy (Group B,
Division 3), 3.2.2.42. - 3.2.2.46.
combustible elements, 3.1.5.6., 9.10.6.1.
combustible finishes in, 3.1.5.12.
combustible flooring in, 3.1.5.10.
combustible insulation in, 3.1.5.14.
combustible stairs in, 3.1.5.11.
decorative wood cladding, 3.1.5.24.
definition, 1.4.1.2.[A]
ducts (combustible) in, 3.1.5.18.
exposing building face, 3.2.3.7.
exterior walls, 3.1.5.5., 3.1.5.6.
Index
Index British Columbia Building Code 2018
factory-assembled panels, 3.1.5.7.
fire stops, 3.1.11.3.
firewalls, 3.1.10.1., 3.1.10.2.
flame-spread rating, 3.1.13.8.
glazing and skylights, 3.1.5.4.
high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.70., 3.2.2.71.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.80., 3.2.2.87.
materials permitted in, 3.1.5.1.
medium-hazard industrial occupancy (Group F,
Division 2), 3.2.2.74., 3.2.2.75.
mercantile occupancy (Group E), 3.2.2.64.
metal roof decks, 3.1.14.2.
minor combustible components, 3.1.5.2.
nailing elements, 3.1.5.8.
non-metallic raceways in, 3.1.5.23.
partitions in, 3.1.5.16.
plumbing fixtures, 3.1.5.20.
residential occupancy (Group C), 3.2.2.47.
roofing materials, 3.1.5.3.
support of, 9.10.8.4.
vehicular passageways, 3.2.3.18.
walkways, 3.2.3.19., 3.2.3.20.
wires and cables, 3.1.5.21., 3.1.5.22.
Noncombustible materials
permitted in noncombustible construction, 3.1.5.1.
return air ducts, 3.6.5.8.
Notching of framing members, 9.23.5.2.
Nursing homes, 3.1.8.13., 3.3.3.5., 3.4.1.6.
O
Objectives of the Code
application, 2.1.1.2.[A], 3.2.[A]
definition, 2.2.1.1.[A]
Obstructions
in corridors, 3.3.1.9., 9.9.5.2., 9.9.5.3., 9.9.6.1.
in doorways, 9.9.6.1., 9.9.6.3.
in exits, 3.4.3.3., 9.9.5., 9.9.5.5., 9.9.6.1., 9.9.6.2.
in means of egress, 3.3.1.23., 9.9.5., 9.9.5.5.
Occupancy
and building classification, 3.1.2.1., 9.10.2.
and building size determination, 1.3.3.4.[A]
combination prohibitions, 3.1.3.2., 9.10.9.12.
definition, 1.4.1.2.[A]
and live loads, 4.1.5.3.
multiple (see Multiple occupancies)
Occupant load
and access to exits, 9.9.7.1.
definition, 1.4.1.2.[A]
and exit stairway, 3.4.3.1.
and fire alarm systems, 3.2.4.1.
fire alarm systems, 3.2.4.22.
fire safety requirements, 3.1.17.1.
and means of egress, 9.9.1.3.
and seating, 3.3.2.2.
Odour removal equipment, 6.8.1.3., 9.33.6.14.
Office areas, 4.1.5.3.
Oil-burning equipment, 6.2.1.5., 9.33.5.2.
Open-air storage garages, 9.10.18.8.
Open-air storey
access route, 3.2.5.4.
definition, 1.4.1.2.[A]
exposing building face, 9.10.14.4.
fire containment exception, 3.2.1.5., 3.2.2.80.
low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.90.
storage garages, 6.3.1.4.
unprotected openings, 3.2.3.10.
Openings
(see also Unprotected openings)
through barricades, 8.2.1.3.
in barrier-free path of travel, 3.8.3.2.
care, treatment or detention occupancy, 3.3.3.2.
for ducts, 6.3.2.9., 9.10.5.1., 9.33.6.10.
for escalators, 3.2.8.2.
in exposing building face, 9.10.14., 9.10.15.
in exterior walls, 3.2.3.13., 3.2.3.17., 9.10.12.3.
for fire dampers, 9.24.3.7.
fire protection, 9.10.1.3.
in fire separations, 3.1.8.1., 3.1.8.6., 3.2.3.13., 3.3.3.2.,
3.4.4.4., 9.10.5., 9.10.9.3., 9.10.13., 9.10.13.8.
through floor assemblies, interconnected floor
spaces, 3.2.8.
in garage floors, 3.3.5.4.
in guards, 9.8.8.5.
guards for, 3.3.1.18., 3.4.6.6.
in membrane ceilings, 3.1.9.6., 9.10.5.
for moving walks, 3.2.8.2.
for natural ventilation, 9.32.2.2.
near exterior exits, 9.9.4.4. - 9.9.4.6.
onto landings, 3.4.6.4.
in repair garages, 3.3.3.2.
for stairways, 3.2.8.2.
support of masonry above, 9.20.5.2.
in walls above adjoining roof, 9.10.12.2.
in walls exposed to adjoining roof, 3.2.3.15.
Index
British Columbia Building Code 2018 Index
Operating rooms, 3.3.3.6., 4.1.5.3.
Oriented strand board (see OSB)
Orphanages, 3.2.4.3.
OSB
as cladding, 5.9.1.1., 9.27.2.4., 9.27.3.6., 9.27.5.,
9.27.10.
fire blocks, 9.10.16.3.
fire protection of soffits, 9.10.12.4.
fire stopping, 3.1.11.7.
as interior finish, 9.29.9.
material, 9.3.2.4.
material standard, 5.9.1.1., 9.23.15.2., 9.23.16.2.,
9.23.17.2., 9.27.10.1., 9.29.9.1., 9.30.2.2.
as roof sheathing, 9.3.2.4., 9.23.3.5., 9.23.16.2.
as siding, 9.27.2.4., 9.27.3.6., 9.27.5., 9.27.10.
as subflooring, 9.3.2.4., 9.23.15.2., 9.23.15.5.
thickness, 9.3.2.7.
as underlay, 9.30.2.
as wall sheathing, 9.3.2.4., 9.23.3.5., 9.23.10.2.,
9.23.13., 9.23.17.2., 9.23.17.5.
Outdoor places of assembly, 3.3.2.11.
Outdoor process equipment, 3.2.3.21.
Outdoors
air quality, 6.2.1.2., 6.3.2.14.
air supply rates, 6.3.1.1., 6.3.1.4.
design temperatures, 1.1.3.1., 5.2.1.1., 5.3.1.2.,
5.5.1.2., 6.2.1.2., 9.33.3.2., 9.33.5.1.
Outlet boxes, electrical
combustible, in noncombustible construction,
3.1.5.2.
penetrating fire separations, 3.1.9.2., 3.1.9.3.,
3.1.9.4., 9.10.5.1., 9.10.9.6.
Ovens, fire protection, 9.10.22.
Owner, definition, 1.4.1.2.[A]
Oxidizing gases (see Combustible gases)
P
Paint
in noncombustible construction, 3.1.5.2.
on steel columns, 9.17.3.3., 9.23.8.2.
Parapets
design, 4.1.8.18., 5.6.2.2., 9.20.6.5.
firewalls as, 3.1.10.4.
in noncombustible construction, 3.1.5.3.
Parging
of above-grade masonry, 9.20.13.9.
for dampproofing, 9.13.2.3., 9.13.2.4.
of foundation walls, 9.15.6.
for protection of insulation, 9.25.2.3.
for waterproofing, 9.13.3.3.
Parking areas
access, 3.8.2.5.
accessible path of travel, 3.8.2.5.
ventilation, 6.3.1.4.
Parking decks on roofs, 4.1.5.5.
Parking garages (see Storage garages)
Parking structures, structural design basis, 4.4.2.1.
Particleboard
as interior finish, 9.29.9.
material standard, 9.23.15.2., 9.29.9.1., 9.30.2.2.
subflooring, 9.23.15.2.
thickness, 9.3.2.7.
underlay, 9.30.2.2.
Partitions
dead loads, 4.1.4.1.
definition, 1.4.1.2.[A]
exceptions for mezzanines, 3.2.8.2.
in lieu of sliding doors, 3.3.1.12.
in noncombustible construction, 3.1.5.16.
sliding glass, 3.3.1.19.
Party walls
airtightness, 9.36.2.10.
continuity of insulation, 9.36.2.5.
definition, 1.4.1.2.[A]
fire separations, 9.10.9.
as firewalls, 3.2.3.4., 9.10.11.1.
not as firewalls, 9.10.11.2.
Passageways
as exits, 3.4.1.4.
as means of egress, 9.9.2.1.
vehicular, 3.2.3.18.
Passageways, exterior
as access to exit, 9.9.9.3.
exemptions, 3.4.4.3.
as exits, 3.3.1.15., 3.4.1.5.
fire-resistance rating, 9.10.8.8.
fire separations, 9.9.4.2.
flame-spread rating, 9.10.17.4.
interior finishes, 3.1.13.10.
as means of egress, 3.2.2.12.
Passenger pickup areas, barrier-free, 3.8.3.1.
Path of travel, accessible
access to storeys served by escalators and moving
walks, 3.8.2.3.
apartment buildings, 9.5.2.3.
application of Code, 3.8.2.1.
doors and doorways, 3.8.3.6.
Index
Index British Columbia Building Code 2018
drinking fountains, 3.8.3.10.
elevators, 3.3.1.7., 3.8.2.3., 3.8.3.2., 3.8.3.7.
floor areas, 3.3.1.7., 9.5.2.2.
parking areas, 3.8.2.5.
signs, 3.8.2.4.
universal washrooms, 3.8.3.12.
walkways, 3.8.3.3.
wheelchair spaces, 3.8.2.3., 3.8.3.21.
width, 3.8.3.2.
Patients’ bedrooms, 3.3.3.5., 3.4.1.6., 4.1.5.3.
Pedestrian traffic, construction sites, 8.2.3.1., 8.2.3.2.
Penetrations in fire assemblies, 3.1.9.1.
Penthouses, 3.6.1.1., 4.1.8.1.
Perched groundwater, 1.4.1.2.[A], 4.2.5.5.
Permafrost, 4.2.4.10., 9.15.1.2.
Piers
anchoring to, 9.20.11.6.
dimensions, 9.35.3.4.
Pier-type foundations, 9.15.2.3.
Pilasters, 9.15.5.3., 9.20.8.4.
Pile foundations, 1.4.1.2.[A], 4.1.8.16., 4.2.3.8.
Pipes
clearances, 6.7.1.2., 9.33.8.3.
combustible (see Combustible piping)
corrosion protection, 9.31.2.2.
coverings, 3.6.5.5.
drainage, 9.14.3.
expansion and contraction, 6.7.1.1., 9.33.8.1.
for heating and cooling systems, 9.33.8.
insulation, 3.6.5.5., 6.5.1.1., 9.33.8.2., 9.33.8.4.
materials, 6.7.1.1., 9.14.3.1.
for medical gas, 3.7.3.1.
metal, 9.14.3., 9.31.2.2.
in noncombustible construction, 3.1.5.18., 3.1.5.19.
penetrating fire separations, 3.1.9.2., 3.1.9.5.,
9.10.9.6., 9.10.9.7.
plumbing, 9.31.2.2.
polypropylene, 3.1.5.19.
for service water heating systems, 9.36.4.4.
in shafts, 6.7.1.5.
sleeves for, 6.7.1.4., 9.33.8.4.
standards for drainage, 9.14.3.1.
support, 6.7.1.1., 9.33.8.1.
Plans, specifications and calculations
administration, 2.2.[C]
energy performance compliance, 2.2.8.[C]
environmental separation, 2.2.5.2.[C]
fire protection components, 2.2.3.[C]
foundations, 2.2.4.[C], 2.2.4.6.[C], 2.2.4.7.[C]
general information, 2.2.2.1.[C]
HVAC systems, 2.2.6.2.[C], 6.1.3.1.
site, 2.2.2.2.[C]
sprinkler systems, 2.2.3.2.[C]
structural, 2.2.4.[C], 4.1.1.4.
Plastering, 9.29.4.
Plaster, material standard, 9.29.4.1.
Plates
fastening of, 9.23.3.4.
sill, 9.23.7.
wall, 9.23.11.
Platforms, serving as roofs, 9.26.1.1.
Plenums
in air duct systems, 3.6.5.1.
ceiling assemblies used as, 3.1.9.7.
ceilings used as, 3.6.4.3.
clearances, 3.6.5.6., 6.3.2.6., 9.33.6.8.
combustible, 9.33.6.2.
in combustible construction, 3.1.4.3.
connectors, 9.33.6.2.
construction, 6.3.2.3., 9.33.6.6.
coverings, 3.6.5.4., 9.33.6.4.
crawl spaces used as, 9.18.7.1.
definition, 1.4.1.2.[A]
fittings, 6.3.2.3., 9.33.6.2.
furnace, 9.33.6.6., 9.33.6.7., 9.33.6.8.
insulation, 9.33.6.4.
linings, 3.6.5.4., 6.3.2.5., 9.33.6.4.
materials, 6.3.2.3., 9.33.6.2., 9.33.6.3.
in noncombustible construction, 3.1.5.18.
return air, 3.6.4.3., 9.32.3.4.
Plumbing
accessible design, 3.8.2.8.
combustible piping, 9.10.9.7.
in dwelling units, 3.7.2., 9.31.
facilities required, 3.7.2., 3.8.2.8., 9.31.4.
fixtures, 3.1.5.20., 3.7.2., 9.31.4.
Plumbing services, 7
Plumbing systems
definition, 1.4.1.2.[A]
design and installation, 7.1.2.1.
in dwelling units, 7.1.3.2.
facilities required, 7.1.3.
Plywood
as cladding, 5.9.1.1., 9.27.2.4., 9.27.3.6., 9.27.5., 9.27.8.
fastening, 9.29.6.3.
fire blocks, 9.10.16.3.
fire protection of soffits, 9.10.12.4.
fire stops, 3.1.11.7.
Index
British Columbia Building Code 2018 Index
grooved, 9.29.6.2.
as interior finish, 9.29.6.
lapped strips, 9.27.8.5.
material, 9.3.2.4.
material standards, 5.9.1.1., 9.23.15.2., 9.23.16.2.,
9.23.17.2., 9.27.8.1., 9.30.2.2.
as roof sheathing, 9.3.2.4., 9.23.3.5., 9.23.16.2.,
9.23.16.6., 9.23.16.7.
as siding, 5.9.1.1., 9.27.8.
as subflooring, 9.23.3.5., 9.23.15.
thickness, 9.3.2.7., 9.29.6.1.
as underlay, 9.30.2.
as wall sheathing, 9.23.3.5., 9.23.10.2., 9.23.13.,
9.23.17.2., 9.23.17.5.
Police stations, 3.1.2.4.
Pool heaters, 9.36.4.2.
Portable fire extinguishers, 3.2.5.16., 9.10.20.4.,
9.10.21.8.
Post-disaster buildings
definition, 1.4.1.2.[A]
earthquake load and effects, 4.1.8.1., 4.1.8.5.,
4.1.8.10., 4.1.8.13., 4.1.8.14.
loads and effects, 4.1.2.1.
snow loads, 4.1.6.2.
structural loads, 5.2.2.1.
wind loads, 4.1.7.3.
Potable water systems, 9.31.3.
Power-operated doors, 3.8.2.7., 3.8.3.6.
Precipitation
ingress, 5.6.1.1., 5.6.2.1., 9.27.2.
protection from, 5.6.1.1., 5.6.2.1., 9.20.13., 9.26.
Pressure piping, 6.2.1.5., 9.33.5.2.
Pressure vessels, 6.2.1.5., 9.33.5.2.
Principal entrances
accessible, 3.8.2.2.
access routes, 3.2.5.4., 3.2.5.5.
door requirements, 9.7.2.1.
as exits, 3.3.1.17., 3.4.2.6.
latching, locking and opening mechanisms, 9.9.6.7.
manual fire alarm stations, 3.2.4.16.
as means of egress, 9.9.2.4.
signs, 3.1.2.6.
Private sewage disposal systems (see Sewage disposal
systems, private)
Process plants
basements and pits, 3.3.6.9.
definition, 1.4.1.2.[A]
volatile liquids, 3.3.6.9.
Protected floor space, 1.4.1.2.[A], 3.2.8.5., 3.4.3.2.
Protection from freezing
(see also Frost action)
concrete, 9.3.1.9.
concrete stairs, 9.8.10.3.
excavations, 9.12.1.3.
fire hose stations, 9.10.21.9.
fire protection systems, 3.2.5.17., 9.10.20.5.
foundations, 9.12.1.3.
gypsum board, 9.29.5.10.
HVAC systems and equipment, 6.2.1.6., 9.33.4.,
9.33.4.5.
masonry, 9.20.14.1.
stucco, 9.28.6.1.
Protection from high temperature piping, 6.7.1.4.,
9.33.8.4.
Public areas
(see also Corridors)
glass doors in, 3.3.1.19.
glass used in, 3.3.1.14., 9.6.1.4.
transparent panels used in, 3.3.1.19., 9.6.1.4., 9.7.5.
windows in, 3.3.1.19., 9.7.5.
Public corridors
(see also Corridors)
access to exit, 9.9.9.1., 9.9.9.3.
containing occupancy, 9.10.17.7.
definition, 1.4.1.2.[A]
doors and door hardware, 3.3.1.13.
doors opening onto, 9.10.13.12.
emergency lighting, 3.2.7.3., 9.9.12.3.
exit signs, 3.4.5.2.
fire separations, 3.3.1.4.
flame-spread rating, 3.1.13.6., 9.10.17.2., 9.10.17.5.
lighting, 3.2.7.1., 9.9.12.2.
serving sprinklered buildings, 3.3.1.1.
smoke control measures, 3.2.6.2.
travel distance to exit, 3.4.2.5.
width, 3.3.1.9.
Public thoroughfares, 3.2.3.9., 3.2.5.6., 9.10.20.3.
Public ways
combustible projections near, 3.2.3.6.
at construction sites, 8.2.1.1., 8.2.3.2., 8.2.3.5.,
8.2.4.1.
definition, 1.4.1.2.[A]
Pyritic soil and rock
drainage, 9.14.2.1., 9.14.4.1.
beneath floors-on-ground, 9.16.2.2.
and footings, 9.15.3.2.
foundations on, 9.4.4.4.
not in backfill, 9.12.3.3.
Index
Index British Columbia Building Code 2018
R
Raceways
collapse of, in firewalls, 3.1.10.1.
in combustible construction, 3.1.4.4.
in exit areas, 3.4.4.4.
and fire alarm systems, 3.2.4.2.
in noncombustible construction, 3.1.5.21., 3.1.5.23.
penetrating fire separations, 3.1.9.2., 9.10.9.6.
in plenums, 3.6.4.3.
Radiation from interior fires, control, 3.2.3.1., 9.10.14.,
9.10.15.
Radiators, 6.7.1.3., 9.33.7.1.
Radon gas infiltration
(see also Soil gas control)
air barriers, 9.25.3.
depressurization system, 9.32.3.8.
and HVAC design, 6.2.1.1.
required resistance to, 5.4.1.1.
rough-in for subfloor depressurization system,
9.13.4.3.
Rafters
anchoring to masonry, 9.20.11.4.
continuity, 9.23.14.1.
deflection, 9.4.3.1.
dimensions, 9.23.4.2., 9.23.14.6., 9.23.14.7.
fastening, 9.23.3.4., 9.23.14.4.
framing around openings, 9.23.14.2.
hip and valley, 9.23.14.6.
installation, 9.23.14.4.
lumber grade, 9.3.2.1.
nailing, 9.23.3.4., 9.23.14.4.
ridge support, 9.23.14.8.
shaping, 9.23.14.5.
spans, 9.23.4.2., 9.23.4.5., 9.23.14.7.
support, 9.23.14.3., 9.23.14.7.
in wood-frame construction, 9.23.14.
Rain loads, 4.1.6.4., 4.1.6.12., 9.4.2.2.
(see also Moisture index)
Rain penetration control, 5.6., 9.20.13., 9.26., 9.27.4.
Ramps
barrier-free, 3.8.2.2., 3.8.3.2., 3.8.3.5., 9.8.5.1.
barrier-free floor areas, 3.3.1.7.
basement, 3.4.5.2.
at doors, 9.8.6.2., 9.9.4.4.
for dwelling units, 9.8.1.
as exits, 3.4.1.4., 9.8.1.3., 9.9.2.1.
exit signs, 9.9.11.4.
finishes, 9.8.9.6.
in garages, 9.8.8.4.
guards, 3.4.6.6., 3.8.3.5., 9.8.8.
handrails, 3.4.6.5., 3.8.3.5., 9.8.7., 9.8.7.1.
height, 9.8.5.5.
height over, 9.8.5.3.
for housing and small buildings, 9.8.5.
landings on, 3.4.6.3., 9.8.6.
loads, 9.8.9.1.
rise, 9.8.5.5.
safety requirements, 3.3.1.14.
for secondary suites, 9.8.1.
slip-resistance, 3.4.6.1., 9.8.9.6.
slope, 3.4.6.7., 3.8.3.5., 9.8.5.4.
width, 3.4.3.2., 9.8.5.2.
Ranges (see Stoves)
Receptacles, electrical, 9.34.1.1., 9.34.2.2.
Recessed lighting fixtures, 3.2.7.2., 9.34.1.4.
Recesses, 9.20.7.
Referenced documents, 1.3.1., 1.5.1.[A]
Reference house
definition, 9.36.5.2.
energy step code, 9.36.6.
modeling of energy performance,
9.36.5.13. - 9.36.5.16.
Refrigerating systems and equipment
in housing and small buildings, 9.33.9.
installation, 6.2.1.5., 6.6.1.1., 9.33.5.2., 9.33.9.1.
Refuse
bins, 3.6.3.3.
chutes, 3.6.3.3., 5.8.1.1., 9.10.1.3.
combustible, 9.10.10.6.
rooms, 3.6.2.5., 3.6.3.3.
Registers and outlets
(see also Air outlets; Diffusers)
exhaust, 6.3.2.10., 9.32.3.13.
heating, 9.33.6.10., 9.33.6.11.
over pipeless furnaces, 9.33.6.8.
ventilation, 9.32.3.5., 9.32.3.6.
Reinforced concrete, 4.3.3.1., 9.3.1.1.
Reinforcing
concrete block foundations, 9.20.15.2.
earthquakes, 9.20.1.2., 9.20.15.
glass block, 9.20.9.6.
insulating concrete form walls, 9.3.1.1., 9.15.4.5.,
9.20.17.
masonry, 9.20.15.
stucco, 9.28.1.2., 9.28.4.5.
Repair garages
definition, 1.4.1.2.[A]
Index
British Columbia Building Code 2018 Index
fire separation requirements, 9.10.9.17.
in industrial occupancies, 3.3.5.4.
separation from care, treatment or detention
occupancies, 3.3.3.2.
solid-fuel burning appliances prohibited in, 3.6.2.1.
Residential care homes, 3.1.2.5., 9.10.2.2.
Residential fire warning systems, 3.2.4.21., 9.10.19.8.
Residential occupancy (Group C)
(see also Dwelling units; Secondary suites)
below ground level, 3.2.2.15.
classification, 3.1.2.1., 9.10.2.
convalescent and children’s homes as, 3.1.2.5.
definition, 1.4.1.2.[A]
door hold-open devices, 3.1.8.14.
emergency power for fire alarm systems, 3.2.7.8.
emergency power for lighting, 3.2.7.4.
fire access route design, 3.2.5.6.
fire alarm systems, 3.2.4.1., 3.2.4.11., 3.2.4.18.,
9.10.18.
fire protection, 3.2.2.47. - 3.2.2.54.
fire-resistance rating, 9.10.8.
fire safety within floor areas, 3.3.1., 3.3.4.1.
fire separations, 9.10.9.11., 9.10.9.12., 9.10.9.14.
firewalls, 9.10.11.2.
flame-spread rating, 3.1.13.3., 9.10.17.
lighting requirements, 3.2.7.1.
location of smoke/fire dampers, 3.1.8.7.
occupant load, 3.1.17.1.
ramp slope maximum, 3.4.6.7.
smoke alarms, 3.2.4.20., 9.10.19.
smoke control measures, 3.2.6.2.
sprinkler piping, 3.2.5.13.
sprinkler systems, 3.2.5.12.
storage lockers, 3.1.5.17.
Resilient flooring, 9.30.2.1., 9.30.5.
Resistance to deterioration, 5.1.4.2., 9.20.16.1.
(see also Corrosion protection; Corrosion
resistance; Decay, protection against)
Resistance to forced entry
doors, 9.7.5.2.
windows, 9.7.5.3.
Resistant design, earthquake load, 4.1.3.2.
Restaurants, 3.2.4.1., 3.3.2.15., 6.3.1.7.
Return air inlets, 9.33.6.12.
Return air systems, 3.6.5.8., 6.3.2.11., 9.33.6.13.
(see also Air intakes; Ducts)
Return ducts, 1.4.1.2.[A], 6.3.2.11., 9.33.6.13.
Review of work, 2.2.7.[C]
Revolving doors, 3.4.6.15., 9.9.6.4.
Rim joists
airtightness, 9.36.2.10.
definition, 1.4.1.2.[A]
effective thermal resistance, 9.36.2.6.
and exterior wall framing, 9.23.3.4.
Risers
aisle steps, 3.3.2.5.
bleacher steps, 3.3.2.12.
curved flights, 3.3.1.16.
dimensions, 3.4.6.8., 9.8.4.1.
minimum number, 3.4.6.2., 9.8.3.2.
restaurant stairs, 3.3.2.15.
uniformity and tolerances, 3.4.6.8., 9.8.4.4.
Rock
bearing pressure, 9.4.4.1., 9.4.4.2.
definition, 1.4.1.2.[A]
foundations on, 9.12.2.2.
Rock, pyritic
drainage, 9.14.2.1., 9.14.4.1.
beneath floors-on-ground, 9.16.2.2.
and footings, 9.15.3.2.
foundations on, 9.4.4.4.
not in backfill, 9.12.3.3.
Roof aggregate, 9.26.11.1., 9.26.11.4.
Roof arches (see Roof and ceiling framing)
Roof assemblies
effective thermal resistance, 9.36.2.6.
fire-resistance rating, 3.1.7.5., 3.2.2.17., 3.2.2.25.,
3.2.2.35., 3.2.2.49., 3.2.2.52., 3.2.2.56., 3.2.2.60.,
3.2.2.66., 3.2.2.76., 3.2.2.81., 3.2.2.83.
non-contiguous, 3.1.15.2., 3.2.2.50., 3.2.2.58.
Roof and ceiling framing
bearing on cavity walls, 9.20.8.2.
fire-resistance rating, 3.1.7.3.
in heavy timber construction, 3.1.4.7.
loads on, 9.4.2.2., 9.4.2.4.
in noncombustible construction, 3.1.5.3.
sheathing, 9.3.2.4., 9.23.16.
trusses, 9.4.2.2., 9.23.5.5., 9.23.14.11.
in wood-frame construction, 9.23.14.
Roof coverings, 3.1.15.1., 3.1.15.2., 9.26.
(see also Roofing)
Roofing
(see also Roof covering)
asphalt shingles, 5.6.1.2., 5.9.1.1., 9.26.1.3., 9.26.2.1.,
9.26.7., 9.26.8.
bituminous, 9.26.2.1.
built-up, 5.9.1.1., 9.26.11.
built-up materials, 9.26.2.1.
Index
Index British Columbia Building Code 2018
cedar shingles and shakes, 9.26.2.1., 9.26.3.1.,
9.26.10.
clay tile, 9.23.4.5.
concrete tile, 5.9.1.1., 9.23.4.5., 9.26.2.1., 9.26.17.
definition, 9.26.1.1.
elastomeric sheets, 5.9.1.1., 9.26.2.1.
fasteners, 9.26.2.3., 9.26.2.4.
flashing, 9.26.4.
glass-reinforced polyester, 9.26.14.
installation alternatives, 9.26.1.3.
installation of materials, 9.26.2.2.
installation standards, 5.6.1.2.
material standards, 9.26.2.1.
metal, 9.26.13.
nails, 9.26.2.3.
over wood-based sheathing, 9.26.11.8.
polyvinyl chloride sheets, 5.6.1.2., 5.9.1.1., 9.26.2.1.,
9.26.16.
prefabricated bituminous membranes, 9.26.2.1.
prefabricated modified bituminous membranes, 5.9.1.1.
requirement for, 5.6.1.1., 9.26.1.2.
rubberized asphalt, 5.6.1.2., 9.26.2.1., 9.26.15.
selvage, 9.26.12.
slope of, 9.26.3.
standards for, 5.9.1.1.
staples, 9.26.2.4.
vegetative, 5.6.1.2.
wood shakes, 9.26.10.
wood shingles, 9.26.9.
Roofs
access, 3.2.5.3.
acting as diaphragms, 4.1.8.15., 4.1.8.18.
anchorage of, 9.20.11.1., 9.20.11.4., 9.20.17.6.
appliances mounted on, 3.6.1.5., 6.4.1.2., 9.10.1.3.
arched or curved, snow loads, 4.1.6.10.
beams, 9.23.4.2., 9.23.4.5.
considered as walls, 3.2.1.3., 9.10.1.1.
definition, 9.26.1.1.
deflection, 9.4.3.1.
drains, 5.6.2.2., 9.26.18.2.
egress from, 3.3.1.3., 9.9.7.1.
fire blocks, 9.10.16.1.
fire rating, 9.10.3.3.
fire-resistance rating, 9.10.8.1., 9.10.8.2., 9.10.8.7.
fire-retardant-treated wood, 3.1.14.1.
fire separations, 3.2.2.13.
firewall termination, 3.1.10.3.
framing, 9.23.4., 9.23.14.
framing around openings, 9.23.14.2.
gable, snow loads, 4.1.6.9.
guards, 3.3.1.18.
heavy timber construction, 3.1.4.7., 3.2.2.16.
helipad loads, 4.1.5.13.
insulation, 9.25.2.2.
joists, 9.23.4.2., 9.23.4.5., 9.23.14.1., 9.23.14.7.,
9.23.14.9.
loads due to use, 4.1.5., 9.4.2.4.
metal decking, 3.1.14.2.
multi-level, 4.1.6.5.
in noncombustible construction, 3.1.5.3.
parapets, 3.1.5.3., 3.1.10.4., 4.1.8.18., 5.6.2.2.,
9.20.6.5.
rain loads, 4.1.6.4., 5.6.2.2., 9.4.2.2.
ridge support, 9.23.14.8.
sheathing installation, 9.23.16.3., 9.23.16.4.,
9.23.16.6.
sheathing materials, 9.3.2.1., 9.3.2.4., 9.23.16.2.,
9.23.16.5., 9.23.16.7.
sloped, 4.1.6.12., 9.10.1.1.
snow loads, 4.1.6.2., 4.1.6.3., 4.1.6.5., 4.1.6.7.,
4.1.6.8., 4.1.6.11., 4.1.6.12., 9.4.2.2.
sprinklers in lieu of structural fire resistance,
9.10.8.2.
supporting an occupancy, 3.2.2.13., 9.10.8.7.
trusses, 9.4.2.2., 9.23.5.5., 9.23.14.11.
of underground structures, 9.13.1.1., 9.13.3.,
9.25.3.5.
venting, 9.19.1.
wind loads, 4.1.7.6., 5.2.2.2.
Roof spaces (see Attics or roof spaces)
Roof-top
air-handling equipment, 6.3.2.17.
appliances, 3.6.1.5., 3.6.2.1., 6.4.1.2., 9.10.1.3.
enclosures, 3.2.1.1., 3.2.2.14., 9.10.4.4.
Rooms, height, 3.7.1.1., 9.5.3.
Runners, sheet steel framing
fastening, 9.24.3.1.
in fire-rated walls, 9.24.3.2.
installation, 9.24.3.1.
metal thickness, 9.24.1.3., 9.24.2.3., 9.24.2.4.
at openings, 9.24.2.4.
Runs, stairs
aisle steps, 3.3.2.5.
bleacher steps, 3.3.2.12.
curved flights, 3.3.1.16.
definition, 1.4.1.2.[A]
landing dimensions, 3.4.6.4.
minimum, 3.4.6.8.
Index
British Columbia Building Code 2018 Index
rectangular treads, 9.8.4.2.
tapered treads, 3.3.1.16., 3.4.6.9., 9.8.4.3.
uniformity and tolerances, 9.8.4.4., 9.8.4.5.
S
Safety glass
in guards, 9.8.8.7.
on revolving doors, 3.4.6.15.
standards for, 9.6.1.2.
transparent panels and doors, 3.3.1.19., 3.4.1.8.
uses, 9.6.1.4.
washrooms, 3.7.2.5.
Safety of public, construction and demolition sites,
8.2.
Sanitary drainage systems, 1.4.1.2.[A], 9.31., 9.31.2.1.,
9.31.5.
Sawtooth roofs, wind loads, 4.1.7.6.
Scaffolding, 4.1.1.3.
Screens
in exhaust outlets, 6.3.2.9., 9.32.3.13.
in intake openings, 6.3.2.9., 9.32.3.13.
in natural ventilation openings, 9.32.2.2.
Screw installation
gypsum board, 9.29.5.9.
sheet steel framing, 9.24.1.5., 9.24.3.1.
Screws
dimensions, 9.23.3.5.
fastening to steel studs, 9.24.1.4.
for gypsum board, 9.29.5.5., 9.29.5.7.
sheathing, 9.23.3.5.
standard for, 9.23.3.1., 9.24.1.4., 9.29.5.7.
subflooring, 9.23.3.5.
wood-frame construction, 9.23.3.5.
Sealants
cladding, 9.27.4., 9.27.8.4., 9.27.9.3., 9.27.9.4.,
9.27.10.3.
material properties, 9.27.4.2.
material standards, 9.27.4.2.
in noncombustible construction, 3.1.5.2.
siding, 9.27.4., 9.27.8.4., 9.27.9.3., 9.27.9.4., 9.27.10.3.
windows, doors and skylights, 9.7.6.2.
Sealing
(see also Air barrier systems; Soil gas control;
Waterproofing)
against precipitation, 5.6.2., 9.27.4.
against soil gas, 9.25.3.6.
air barrier systems, 5.4.1.2., 9.10.9.16., 9.10.9.17.,
9.25.3.3.
at chimneys, 9.21.5.2., 9.25.3.3.
ducts, 3.6.5.3., 6.3.2.19., 9.32.3.11., 9.33.6.3., 9.33.6.7.
floors-on-ground, 9.25.3.6.
at gas vents, 9.25.3.3.
ground cover, 9.18.6.2.
sill plates, 9.23.7.2.
windows, doors and skylights, 9.7.6., 9.20.13.11.,
9.27.4.
Seasonally and intermittently occupied buildings
application of Part 9, 9.1.1.1.
ventilation, 6.3.1.3.
Seating
aisle width, 3.3.2.1.
not fixed, 3.3.2.2.
occupant load, 3.3.2.2., 4.1.5.10.
in showers, 3.8.3.16.
wheelchair space, 3.8.2.3., 3.8.3.21.
Secondary suites, 9.37.
Seismic data, 1.1.3.
Seismic isolation
definitions and analysis, 4.1.8.19.
design provisions, 4.1.8.20.
Seismic loads (see Earthquake design)
Self-closing devices, 3.1.8.13., 3.4.6.13., 9.9.6.7.,
9.10.13.10., 9.10.13.15.
Self-contained emergency lighting, 3.2.7.4., 9.9.12.3.
Self-service storage buildings, 3.9.
Self-storage warehouses, 3.3.5.9., 9.9.6.4.
Septic disposal beds, 9.14.6.2.
Service lines under buildings, 3.2.3.21.
Service rooms
access to exit, 9.9.7.5.
application of Code, 3.6.1.1.
and building height, 9.10.4.4.
carbon monoxide alarms, 9.32.3.9.
construction supporting, 9.10.8.5.
definition, 1.4.1.2.[A]
doors, 9.10.13.12.
doors and door hardware, 3.3.1.13., 3.4.6.11.
emergency lighting, 3.2.7.3.
exits, 3.4.4.4., 3.6.2.2.
fire alarm systems, 3.2.4.2.
fire detectors, 3.2.4.10.
fire resistance of supporting construction, 3.1.7.5.
fire separations, 3.6.2.1., 9.10.10.3.
heat and smoke detectors, 9.10.18.4.
for housing and small buildings, 9.10.10.
loads on floor or roof, 4.1.5.3.
opening into exit, 9.9.5.9.
Index
Index British Columbia Building Code 2018
ramps and stairways, 3.3.1.14.
roof-top, 3.2.1.1., 3.2.2.14., 9.10.4.4.
service equipment in, 3.6.2.3.
under exits, 9.9.5.8.
Service spaces
and building height, 3.2.1.1.
definition, 1.4.1.2.[A]
egress, 3.3.1.24.
emergency lighting, 3.2.7.3.
exits, 3.4.4.4.
fire alarm systems, 3.2.4.18.
horizontal (see Horizontal service spaces)
lightning protection systems, 3.6.1.3.
means of egress, 3.3.1.3.
protection of electrical conductors, 3.2.7.10.
ramps and stairways, 3.3.1.14.
signage, 3.3.1.24.
sprinkler systems, 3.2.5.14.
storage use prohibition, 3.6.1.4.
travel distance to exit, 3.4.2.4.
vertical (see Vertical service spaces)
Service water heaters
definition, 1.4.1.2.[A]
in housing and small buildings, 9.31.6.
indirect, 1.4.1.2.[A]
protection from corrosion, 9.31.6.3.
steel, 9.31.6.3.
storage type, 1.4.1.2.[A], 9.31.6.2., 9.31.6.3.
Service water heating systems
energy efficiency, 9.36., 9.36.4.
energy performance calculations, 9.36.5.8.
energy performance modeling, 9.36.5.12., 9.36.5.16.
equipment efficiency, 9.36.4.2.
temperature controls, 9.36.4.5.
Sewage disposal, 9.14.5., 9.31.2.1., 9.31.5.
Sewage disposal systems, private, 1.4.1.2.[A], 9.31.2.1.,
9.31.5.2.
Shafts
installation, 6.7.1.5.
opening into an interconnected floor space, 3.2.8.4.
piping in, 6.7.1.5.
service, 9.10.1.3.
Shakes, wood
cladding, 9.27.7.
dimensions, 9.27.7.2., 9.27.7.6.
eave protection, 9.26.5.1., 9.26.10.7.
flashing, 9.26.10.6.
grades, 9.26.10.8., 9.27.7.1.
installation, 9.27.5., 9.27.7.3.
material standards, 5.9.1.1., 9.26.2.1., 9.27.7.1.
roofing, 9.26.10.
spacing and joints, 9.26.10.3.
underlay, 9.26.10.2.
Shallow foundations
damaged, 4.2.6.4.
definition, 1.4.1.2.[A]
design, 4.2.6.1.
footing design, 9.4.4.1.
incorrect placement, 4.2.6.3.
support, 4.2.6.2.
Sheathing
(see also Subflooring)
for braced wall panels, 9.23.13.6.
for bracing and lateral support, 9.23.10.2.
in exposing building face, 9.10.14.5., 9.10.15.2.
fastening, 9.23.3.5.
fibreboard as, 9.23.16.7.
installation, 9.23.3.5., 9.23.16.3., 9.23.16.4.,
9.23.17.4., 9.23.17.5.
insulating, 9.20.13.6., 9.27.3.4.
low permeance, 9.25.5.1.
lumber as, 9.3.2.1., 9.23.16.5., 9.23.17.2., 9.23.17.4.
material standards, 9.23.16.2., 9.23.17.2., 9.26.2.1.
in noncombustible construction, 3.1.5.3.
OSB as, 9.3.2.4., 9.23.16.2., 9.23.17.2.
plywood as, 9.3.2.4., 9.23.16.2., 9.23.17.2.
roofs, 9.3.2.1., 9.3.2.4., 9.23.16., 9.26.2.1.
on steel studs, 9.24.1.5.
beneath stucco, 9.28.1.1., 9.28.4.2.
support, 9.23.10.5., 9.24.3.4.
thickness, 9.23.16.7., 9.23.17.2.
waferboard as, 9.3.2.4., 9.23.16.2., 9.23.17.2.
walls, 9.3.2.1., 9.3.2.4., 9.23.17.
Sheathing membranes
installation, 9.27.3.3. - 9.27.3.6.
insulation, 9.27.3.5.
interior of masonry walls, 9.20.13.9.
mansard roofs, 9.23.17.6.
material standard, 9.27.3.2.
for precipitation protection, 9.27.3.1. - 9.27.3.6.
Sheathing paper (see Sheathing membranes)
Shingles, asphalt
eave protection, 9.26.5.1., 9.26.7.7.
flashing, 9.26.4.
installation, 9.26.1.3., 9.26.7., 9.26.8.
material standards, 5.9.1.1., 9.26.2.1.
nails, 9.26.2.3.
slope, 9.26.3.1.
Index
British Columbia Building Code 2018 Index
staples, 9.26.2.4.
underlay, 9.26.6.
Shingles, wood
cladding, 9.27.7.
dimensions, 9.26.9.3., 9.27.7.2., 9.27.7.6.
eave protection, 9.26.9.8.
exposure, 9.26.9.6.
flashing, 9.26.9.7.
grade, 9.26.9.2., 9.27.7.1.
installation, 9.26.9.4., 9.27.2.4., 9.27.5., 9.27.7.3.
materials, 9.27.7.1.
material standards, 5.9.1.1., 9.26.2.1., 9.27.7.1.
roofing, 9.26.9.
Shop drawings, 2.2.7.3.[C]
Showers, 3.8.3.16.
Sidelights, 3.3.1.19., 9.6.1.4., 9.7.1.1., 9.7.2.1., 9.9.4.3.
Sidewalks, 4.1.5.3., 8.2.1.2., 8.2.3.1.
Siding (see Cladding)
Signs
accessibility, 3.8.2.4., 3.8.2.10., 3.8.3.9.
construction sites, 8.2.3.3., 8.2.3.5., 8.2.4.1.
directing traffic, 8.2.4.3.
egress points, 3.3.1.24.
emergency crossover access to floor areas, 3.4.6.18.
exit obstruction prevention, 3.4.6.11., 9.9.11.2.
exits, 3.4.5.1., 9.9.11., 9.9.11.3.
floor numbers, 3.4.6.19., 3.5.4.2., 9.9.11.5.
graphical symbols, 3.4.5.2.
occupant load, 3.1.17.1.
stairs and ramps, 9.9.11.4.
Silencing devices, 3.2.4.18., 3.2.4.20., 3.2.4.22., 3.2.6.7.
Sill plates
dimensions, 9.23.7.1.
leveling, 9.23.7.2.
sealing, 9.23.7.2.
standard for, 9.23.7.
Site plans, 2.2.2.2.[C]
Site stability, earthquake design, 4.1.8.17.
Skylights
airtightness, 9.36.2.9., 9.36.2.10.
area, 9.10.17.9.
in area calculations, 9.10.17.6.
combustible, in corridors, 3.1.13.5.
flame-spread rating, 3.1.13.2., 9.10.17.1.
glass standards, 9.6.1.3.
in housing and small buildings, 9.7.
installation, 9.7.6.
manufactured and pre-assembled, 9.7.4.
in noncombustible construction, 3.1.5.4.
performance expectations, 9.7.3.
requirements, 9.7.2.2.
on roof adjacent to wall with windows, 3.2.3.15.
site-built, 9.7.5.
standards for, 5.4.1.2., 5.9.2.1., 5.9.2.2., 9.7.4.
thermal characteristics, 9.7.3.3., 9.36.2.7.
in unsprinklered compartments, 9.10.12.2.
Slabs-on-ground
(see also Floors-on-ground)
bond break, 9.16.4.4.
concrete, 9.16.4.
ducts in or beneath, 9.33.6.7.
finishing, 9.16.4.1., 9.16.4.2.
insulation, 9.25.2.3.
thickness, 9.16.4.3.
Sleepers, 9.30.1.3.
Slide escapes, 3.4.1.6.
Sliding doors
accessible, 3.8.3.6.
exits, 3.4.6.14.
glass used in, 9.6.1.4.
as means of egress, 3.3.1.12., 9.9.6.4.
performance expectations, 9.7.3.1., 9.7.3.2.
standards for, 5.3.1.2., 5.4.1.2., 9.7.4.2.
Slip-resistance
accessible path of travel, 3.8.3.2.
bathtubs, 3.8.3.17.
exterior walks, 3.8.3.3.
ramps and stairways, 3.3.1.14., 3.4.6.1.
showers, 3.8.3.16.
treads and landings, 9.8.9.6.
Smoke
circulation prevention, 3.2.4.12., 9.10.18.5.
contamination, 3.2.6.2., 3.2.8.4.
control of, 3.1.8.14., 3.2.6.1., 3.2.6.9., 3.3.1.7., 3.3.3.5.,
3.3.3.7.
Smoke alarms
definition, 1.4.1.2.[A]
in housing and small buildings, 9.10.19.
interconnection, 9.10.19.5.
location, 9.10.19.3.
maintenance and care instructions, 9.10.19.7.
power supply, 9.10.19.4.
requirements, 3.2.4.20., 9.10.19.1.
silencing, 9.10.19.6.
smoke detectors in lieu of, 3.2.4.20., 3.2.4.21.
sound patterns, 9.10.19.2.
Smoke barrier doors, 3.2.3.20.
Smoke barriers, 9.10.9.2., 9.10.9.15.
Index
Index British Columbia Building Code 2018
Smoke chambers
clearances, 9.22.9.3.
slope, 9.22.7.1.
standard for, 9.22.7.
wall thickness, 9.22.7.2.
Smoke dampers
access, 3.1.8.11.
as closures, 3.1.8.5.
in fire separations, 3.1.8.7.
installation, 3.1.8.11.
leakage rates, 3.1.8.4.
waived, 3.1.8.9.
Smoke detectors
in air-handling systems, 6.9.2.2., 9.10.18.5.
annunciators, 3.2.4.8.
for construction camps, 9.10.21.7.
definition, 1.4.1.2.[A]
design and installation, 9.10.18.3.
duct-type, 3.2.4.12.
in electrical equipment rooms, 3.6.2.7.
in elevators, 3.2.4.11., 3.2.4.14.
in fire alarm systems, 9.10.18.
in lieu of smoke alarms, 3.2.4.20., 3.2.4.21., 9.10.19.8.
and release of hold-open devices, 3.1.8.14.
requirements, 3.2.4.11., 9.10.18.4.
Smoke developed classification
duct requirements, 3.6.5.1.
high buildings, 3.1.13.7.
plenum requirements, 3.6.4.3.
tests, 3.1.12.1.
Smoke shafts (venting to aid firefighting), 3.2.6.6.
Smoke stacks (venting for chimneys), 6.3.3.3.
Snow accumulation, 4.1.6.2., 4.1.6.3., 4.1.6.7., 4.1.6.10.,
5.6.2.2.
Snow loads
arch roofs, 4.1.6.10.
areas adjacent to roof projections, 4.1.6.7.
basic load factors, 4.1.6.2.
curved roofs, 4.1.6.10.
domes, 4.1.6.10.
due to sliding, 4.1.6.11.
exterior platforms, 9.4.2.3.
full and partial, 4.1.6.3.
gable roofs, 4.1.6.9.
and gap between roof and higher roof, 4.1.6.6.
multi-level roofs, 4.1.6.5.
snow drift at roof corners, 4.1.6.8., 4.1.6.13.
specified, 4.1.6.2., 9.4.2.2.
and structural design, 4.1.6.
valleys in curved or sloped roofs, 4.1.6.12.
weight calculations for drifts, 4.1.6.13.
Snow removal, 4.1.6.14.
Soffits
projections, 3.2.3.6., 9.10.14., 9.10.14.5., 9.10.15.,
9.10.15.4., 9.10.15.5.
protection of, 3.2.3.16., 9.10.12.4.
venting, 9.19.1.2., 9.19.1.3., 9.25.2.4.
Soil gas control
application of Code, 9.13.1.1.
crawl spaces, 9.13.4.2.
floors-on-ground, 9.16.2.1., 9.25.3.6.
requirements, 5.4.1.1., 9.13.4., 9.13.4.2.
walls in contact with the ground, 9.25.3.4.
Soil, pyritic
drainage, 9.14.2.1., 9.14.4.1.
beneath floors-on-ground, 9.16.2.2.
and footings, 9.15.3.2.
foundations on, 9.4.4.4.
not in backfill, 9.12.3.3.
Soils
bearing pressure, 9.4.4.1., 9.4.4.2.
definition, 1.4.1.2.[A]
erosion control, 5.6.2.2.
excavations, 4.2.5., 9.12.
beneath footings and foundations, 9.12.4.1.,
9.15.1.1., 9.15.3.2.
identification and classification, 4.2.4.3., 9.4.4.
subsurface investigation, 4.2.2.1., 4.2.4.1., 4.2.4.2.
swelling and shrinking, 4.2.4.11., 9.4.4.4., 9.12.3.3.,
9.14.2.1., 9.14.4.1., 9.15.3.2., 9.16.2.2.
temperature, 5.2.1.1., 5.2.1.3., 9.12.2.2., 9.16.2.2.
Solar domestic hot water systems, 9.36.4.3.
Solar thermal systems, 9.36.3.11.
Solid-fuel-burning appliances
carbon monoxide alarms, 6.9.3.1., 9.32.3.9.
design, 9.33.5.3.
fireplace inserts and hearth-mounted stoves, 9.22.10.
and fire separations, 3.6.2.1.
installation standard, 6.2.1.5., 9.22.10.2., 9.33.5.3.
Solid masonry, 1.4.1.2.[A]
Solid masonry units, 1.4.1.2.[A], 9.15.5.1.
Sound
protection from, 3.3.4.6., 5.1.1.1., 5.8.1., 9.11.
rating for fans, 9.32.3.10.
smoke alarms, 9.10.19.3.
Sound transmission class (STC)
calculation of, 5.8.1.2.
compliance, 5.8.1.3.
Index
British Columbia Building Code 2018 Index
definition, 1.4.1.2.[A]
Space heaters
(see also Heating appliances)
definition, 1.4.1.2.[A]
design and standards, 9.33.5.3.
performance requirements, 9.36.3.10.
Space heating appliances
definition, 1.4.1.2.[A]
installation standards, 9.33.5.2.
Spans
maximums, 9.23.4.
steel, 9.23.4.3.
wood, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.4.5.
Spatial separation between buildings, 3.2.3., 9.10.14.,
9.10.21.5.
Spatial separation between houses, 3.2.3.
Special structures, 3.2.2.2.
Sprinklered buildings or spaces
egress from bedrooms, 9.9.10.1.
fire-resistance rating, 9.10.8.2., 9.10.9.15., 9.10.10.6.
fire separations, 3.3.1.4., 3.6.2.5., 9.10.9.6., 9.10.9.13.,
9.10.9.15., 9.10.10.6.
heat and smoke detection, 9.10.18.4.
limiting distance, 9.10.14.3.
lobbies, 3.4.4.2., 9.9.8.5.
openings in exposing building faces, 3.2.3.1.,
9.10.14.4., 9.10.15.4.
openings in fire separations, 9.10.13.8.
and safety within floor areas, 3.3.
service spaces, 3.6.
soffit protection, 9.10.12.4.
and travel distance, 3.4.2.4., 3.4.2.5., 9.9.8.1., 9.9.8.2.,
9.9.8.6.
Sprinklered, definition, 1.4.1.2.[A]
Sprinkler systems
for arena-type buildings, 3.1.2.3.
for assembly occupancy (Group A, Division 1),
3.2.2.20.
for assembly occupancy (Group A, Division 2),
3.2.2.23., 3.2.2.24., 3.2.2.26., 3.2.2.27.
for assembly occupancy (Group A, Division 3),
3.2.2.29., 3.2.2.31., 3.2.2.33.
for assembly occupancy (Group A, Division 4),
3.2.2.35.
for barrier-free floor areas, 3.3.1.7.
for basements, 3.2.1.5.
for business and personal services occupancy
(Group D), 3.2.2.55., 3.2.2.57., 3.2.2.58., 3.2.2.59.,
3.2.2.61., 3.2.2.63.
for care, treatment or detention occupancy (Group
B, Division 1), 3.2.2.36., 3.2.2.37.
for care, treatment or detention occupancy (Group
B, Division 2), 3.2.2.38. - 3.2.2.41.
for care, treatment or detention occupancy (Group
B, Division 3), 3.2.2.42. - 3.2.2.46.
combustible pipes in, 3.1.9.5., 3.2.5.13., 9.10.9.6.
construction of, 3.2.5.12.
for contained use areas, 3.3.3.7.
and controlled egress, 3.4.6.17.
for corridors, 3.1.13.6., 3.3.2.6.
design, 3.2.5.12.
and door hold-open devices, 3.1.8.14.
and egress doorways, 3.3.1.5.
electrical supervision, 3.2.4.9.
exceptions for mezzanines, 3.2.8.2.
for exposing building face, 3.2.3.2.
and fire alarm systems, 3.2.4.1., 3.2.4.7., 3.2.4.8.,
9.10.18.4.
fire department connection, 3.2.5.15.
and firefighting access, 3.2.5.1.
fire hose connections, 3.2.5.10.
fire hose stations, 3.2.5.11.
fire separations in residential occupancy, 3.3.4.2.
flame-spread rating, 3.1.13.8.
for garages, 3.2.1.2., 3.3.5.4., 3.3.5.7.
in heavy timber construction, 3.1.4.7., 3.2.2.16.
for high buildings, 3.1.13.7.
for high-hazard industrial occupancy (Group F,
Division 1), 3.2.2.70.
for impeded egress areas, 3.2.2.19.
installation, 3.2.5.12., 9.10.1.3.
for interconnected floor space, 3.2.8.3.
for libraries, 3.3.2.13.
in lieu of fire detectors, 3.2.4.10.
limiting distance, 3.2.3.1.
for low-hazard industrial occupancy (Group F,
Division 3), 3.2.2.80., 3.2.2.82., 3.2.2.84., 3.2.2.86.,
3.2.2.88.
for medium-hazard industrial occupancy (Group F
Division 2), 3.2.2.74., 3.2.2.75., 3.2.2.77., 3.2.2.79.
for mercantile occupancy (Group E), 3.2.2.64.,
3.2.2.65., 3.2.2.67., 3.2.2.69.
and metal roof deck, 3.1.14.2.
in noncombustible construction, 3.1.5.19.
plans, 2.2.3.2.[C]
for repair garages, 3.3.5.4.
required, 3.2.2.18.
Index
Index British Columbia Building Code 2018
for residential occupancy (Group C), 3.2.2.47.,
3.2.2.48., 3.2.2.50., 3.2.2.51., 3.2.2.54.
self-storage warehouses, 3.3.5.9.
and separation of public corridors, 3.3.1.4.
and separation of suites, 3.3.1.1.
and service penetrations, 3.1.9.5.
for service spaces, 3.2.5.14.
and soffit protection, 3.2.3.16.
stages, 3.3.2.14.
and standpipes, 3.2.5.8., 3.2.5.9.
for storage garages, 3.2.1.2., 3.3.5.4., 3.3.5.7.
for storage rooms, 3.3.4.3.
for storeys below ground, 3.2.2.15.
system monitoring, 3.2.4.15.
testing, 3.2.5.12.
for theatres, 3.3.2.14.
for underground walkways, 3.2.3.20.
and unprotected openings, 3.2.3.1., 3.2.3.12.,
3.2.3.14., 3.2.3.15., 3.2.3.17.
Stability, structural, 4.1.3.2.
Stages, theatrical, 1.4.1.2.[A], 3.3.1.18., 3.3.2.14.
Stairs
cantilevered, 9.8.9.2., 9.8.10.
clear height over, 9.8.2.2.
concrete, 9.8.9.2., 9.8.10.
construction, 9.8.9.
curved, 3.3.1.16., 3.4.6.5., 3.4.6.9., 9.8.3.1.
dimensions, 3.3.2.15., 9.8.2.
doors onto, 3.4.6.3., 3.4.6.11., 9.8.6.2., 9.9.4.4.,
9.9.6.6.
in dwelling units, 3.3.4.7., 9.8.
for exits, 9.8.1.3., 9.8.2.1., 9.8.3.1., 9.9.9.3.
exit signs with, 9.9.11.4.
exterior, 9.3.1.6., 9.8.9.2., 9.8.9.3.
finishes, 3.4.6.1., 9.8.9.6.
fire blocks required, 3.1.11.4., 9.10.16.1.
on fire escapes, 3.4.7.5.
with foundations, 9.12.2.2.
guards for, 9.8.8.
handrails, 3.4.6.5., 9.8.7., 9.8.7.1.
height of, 9.8.3.3.
horizontal exit prohibition, 3.4.6.10.
landings (see Landings)
loads on, 9.8.9.1.
in noncombustible construction, 3.1.5.11.
nosings, 9.8.4.8.
permitted configurations, 9.8.3.1.
in restaurants, 3.3.2.15.
rise, 3.4.6.8., 9.8.3.3., 9.8.4.1., 9.8.4.4.
risers (see Risers)
runs (see Runs, stairs)
in secondary suites, 9.8.
slip-resistance, 3.4.6.1., 9.8.9.6.
spiral, 9.8.3.1., 9.8.4.7.
tolerances, 9.8.4.4.
treads (see Treads)
vertical rise, 3.4.6.3.
width, 9.8.2.1.
winders, 9.8.3.1., 9.8.4.6.
wood, 9.8.9.3., 9.8.9.4.
Stairways
as exits, 3.2.3.13., 3.4.1.4., 3.4.2.3., 3.4.3.3., 3.4.6.6.,
9.9.4.7.
headroom clearance, 3.4.3.4., 9.8.2.2., 9.8.6.4.
landings, 3.4.3.3.
lighting, 3.2.7.1., 9.9.12.2., 9.34.2.3.
in means of egress, 9.9.1.1.
mezzanine egress, 9.9.8.6.
projections into, 9.8.7.6.
requirements, 3.3.1.14.
roof-top enclosures, 3.2.2.14.
weather protection, 3.3.5.4., 3.4.6.11.
width, 3.4.3.2., 3.4.3.3., 9.8.2.1.
Standards, materials, 1.5.[A], 5.9.1.1.
Standpipe systems
in construction camps, 9.10.21.9.
design, 3.2.5.9.
fire department connection, 3.2.5.15.
fire hose connections, 3.2.5.10.
fire protection, 9.10.1.3.
installation, 3.2.5.9.
requirements, 3.2.5.8.
testing, 3.2.5.9.
trouble switch, 3.2.4.9.
Staples
for cladding, 9.27.5.4.
dimensions, 9.23.3.5., 9.26.2.4., 9.27.5.4.
for roofing, 9.26.2.4.
for sheathing, 9.23.3.5.
for stucco lath, 9.28.3.2.
for subflooring, 9.23.3.5.
for underlay, 9.30.2.3.
for wood strip flooring, 9.30.3.4.
Stapling
asphalt shingles, 9.26.7.4., 9.26.7.6., 9.26.8.5.
cladding, 9.27.5.4., 9.27.7.3.
plywood finish, 9.29.6.3.
roofing, 9.26.7.4., 9.26.7.6., 9.26.8.5., 9.26.9.5.
Index
British Columbia Building Code 2018 Index
sheathing, 9.23.3.5.
sheathing membrane, 9.27.3.5.
siding, 9.27.5.4., 9.27.7.3.
subflooring, 9.23.3.5.
underlay, 9.30.2.3.
wood-frame construction, 9.23.3.
wood shingles and shakes, 9.26.9.5., 9.27.7.3.
wood strip flooring, 9.30.3.4.
Static procedure, wind load calculations, 4.1.7.3.
Steel
beams, 9.23.4.3., 9.23.8.2.
cold-formed, structural design basis, 4.3.4.2.
columns, 9.10.14.5., 9.10.15.5., 9.17.3.
design, 9.4.1.1.
door frames, 9.10.13.6.
fire protection, 3.2.2.3., 9.10.7.
flashing, 9.20.13.1., 9.27.3.7.
in foundations, 4.2.3.7.
in foundations, high-strength tendons in, 4.2.3.9.
framing, 9.24.
lintels, 9.20.5.2., 9.22.1.2.
protection from corrosion, 4.2.3.10., 5.1.4.2., 9.3.3.2.,
9.17.3.3., 9.20.5.2., 9.20.16., 9.23.8.2.
roofing, 5.9.1.1., 9.26.13.
runners, 9.24.1.2., 9.24.1.3., 9.24.2.3., 9.24.2.4.,
9.24.3.1., 9.24.3.2., 9.24.3.6.
siding, 5.9.1.1., 9.27.11.1.
structural design basis, 4.3.4.
studs, 9.24.1.1., 9.24.2.1., 9.24.2.2., 9.24.2.4., 9.24.2.5.,
9.24.3.2.
Stone
facings, 9.20.6.6.
masonry units, 9.20.2.5.
veneer, 9.20.8.5.
Storage
of ammonium nitrate, 3.3.6.6.
of anhydrous ammonia, 3.3.6.3.
on the building site, 1.2.2.2.[A]
of dangerous goods, 3.3.6.2.
of flammable and combustible liquids, 3.3.6.4.
of flammable, toxic and oxidizing gases, 3.3.6.3.
of materials, 1.2.2.2.[A], 9.10.1.3.
outdoors, 3.2.3.21.
of tires, 3.3.6.5.
Storage areas, theatres, 3.3.2.14.
Storage bins
for ash, 6.9.4.1.
for solid fuel, 6.7.2.1.
Storage buildings, self-service, 3.3.5.9., 9.10.9.20.
application of Code, 3.9.1.2.
definition, 3.9.1.1.
fire safety, 3.9.2.
floor areas, 3.9.3.
occupancy classification, 3.9.1.3.
sanitary facilities, 3.9.3.2.
Storage garages
(see also Garages)
access through vestibule, 3.3.5.7.
in basements, 9.10.4.3.
in buildings with superimposed major
occupancies, 3.2.2.7.
carbon monoxide alarms, 6.9.3.1.
cladding, 9.10.14.5.
construction, 9.10.14.5., 9.35.
definition, 1.4.1.2.[A]
doors, 9.9.6.4., 9.10.17.10.
exhaust to, 6.3.2.10.
exposing building face, 9.10.14.4., 9.10.14.5.
fire alarms, 3.2.4.1., 9.10.18.8.
fire separations, 3.3.5.6., 9.10.9.16.
headroom clearance, 3.3.1.8.
height, 3.3.5.4., 9.5.3.3., 9.9.3.4.
interconnection of ducting, 6.3.2.7., 9.33.6.7.
limiting distance, 9.10.14.4.
in low-hazard industrial occupancies (Group F,
Division 3), 3.2.2.90.
open-air, 9.10.14.4., 9.10.18.8.
openings for vehicular ramps, 3.2.8.2.
pressure less than in adjoining occupancies, 6.3.1.4.
as separate buildings, 3.2.1.2.
standpipes requirement, 3.2.5.9.
unprotected openings in, 3.2.3.10., 9.10.14.4.
ventilation, 3.3.5.4., 6.3.1.4., 9.32.1.1.
Storage lockers, 3.1.5.17.
Storage racks, earthquake design, 4.1.8.18.
Storage rooms
in assembly occupancy, 3.3.2.16.
for combustible garbage, 9.10.10.6.
electrical outlets in, 9.34.2.5.
fire alarm and detection systems, 9.10.18.6.
fire detectors in, 3.2.4.10., 9.10.18.4.
fire separations, 3.3.4.3., 3.6.2.5., 9.10.10.6.
for flammable and combustible liquids, 3.3.6.4.
flooring in areas of dangerous goods, 3.3.6.7.
Storage tanks, 3.1.1.3.
Storage-type service water heaters, 1.4.1.2.[A],
9.31.6.2., 9.31.6.3.
Storefronts (see Fenestration)
Index
Index British Columbia Building Code 2018
Storeys
below ground, 3.2.2.15.
definition, 1.4.1.2.[A]
open-air, 1.4.1.2.[A], 3.2.1.5., 3.2.2.80., 3.2.2.90.,
3.2.3.10., 3.2.5.4., 6.3.1.4., 9.10.14.4.
sprinkler system requirements, 3.2.2.18.
Stoves
(see also Cooktops)
clearances, 9.10.22.2.
definition, 1.4.1.2.[A]
design and installation standard, 9.33.5.2., 9.33.5.3.
hearth-mounted, 9.22.10.
installation, 9.10.22.1.
Strandboard (see OSB)
Strapping, floor joists, 9.23.3.4., 9.23.9.3., 9.23.9.4.
Streets
definition, 1.4.1.2.[A]
exposing building face on, 9.10.14.4.
fire access routes, 3.2.2.10.
repairs following construction, 8.2.3.4.
safe passage past construction sites, 8.2.3.1., 8.2.3.2.
unprotected openings facing, 3.2.3.10.
Stress reversal, 4.1.3.2.
Structural design
Code requirements, 4
housing and small buildings, 9.4.
limit states design, 4.1.3.
and structural loads, 5.2.2.
Structural drawings, 2.2.4.3.[C]
Structural fire protection, 3.2.2.3., 3.2.3.9., 9.10.8.
Structural loads and design procedures, 4.1., 5.2.2.,
5.9.3.2., 9.4.
exterior insulation finish systems, 5.9.4.1.
Structural movement
mechanical systems and equipment, 4.1.8.18.,
6.2.1.4., 9.33.4.7.
service water heaters, 9.31.6.2.
Structures, special, 3.2.2.2.
Stucco
aggregate for, 9.28.2.2., 9.28.5.1.
application, 9.28.6.
fasteners, 9.28.3.1., 9.28.3.2.
flashing for, 9.28.1.5.
ground clearance, 9.28.1.4.
for housing and small buildings, 9.28.
installation, 9.28.1.2., 9.28.1.3., 9.28.3.1., 9.28.3.2.,
9.28.6.
lath (see Lath, stucco)
materials, 9.28.2., 9.28.5.
mixes, 9.28.5.1.
mixing, 9.28.5.3.
nails for, 9.28.3.
pigments, 9.28.5.2.
sheathing beneath, 9.28.1.1., 9.28.4.2.
staples for, 9.28.3.
thickness, 9.28.6.
Studs, steel
bracing and lateral support, 9.24.1.5.
dimensions, 9.24.2.1., 9.24.2.5.
fastening, 9.24.1.4., 9.24.3.6.
in fire-rated walls, 9.24.2.4., 9.24.3.2.
in housing and small buildings, 9.24.
metal thickness, 9.24.1.3., 9.24.2.2., 9.24.2.4.,
9.24.2.5.
notching and drilling, 9.23.5.3.
at openings, 9.24.2.4., 9.24.3.5., 9.24.3.7.
orientation, 9.24.3.3.
spacing, 9.24.2.1., 9.24.2.5.
standard for, 9.24.1.2.
Studs, wood
bracing, 9.23.10.2.
continuity, 9.23.10.4.
at corners and intersections, 9.23.10.5.
dimensions, 9.23.10.1.
lateral support, 9.23.10.2.
lumber grade, 9.3.2.1.
notching and drilling, 9.23.5.3.
at openings, 9.23.10.6.
orientation, 9.23.10.3.
spacing, 9.23.10.1.
standard for, 9.24.1.2.
Subfloor
depressurization, 9.13.4., 9.13.4.3.
direction of installation, 9.23.15.4.
edge support, 9.23.15.3.
lumber, 9.23.15.7.
materials, 9.23.15.2., 9.23.15.7.
nailing, 9.23.15.6.
thickness, 9.23.15.5.
wood-frame construction, 9.23.15.
Subsurface investigation, 1.4.1.2.[A], 2.2.4.6.[C], 4.2.2., 4.2.4.2.
Suites
definition, 1.4.1.2.[A]
doors and door hardware, 3.3.1.13.
fire separations, 9.10.9.13., 9.10.9.14.
separation of, 3.3.1.1.
smoke control measures, 3.2.6.2.
Sump pits, 9.14.5.2.
Index
British Columbia Building Code 2018 Index
Sumps, evaporative air coolers and air washers,
6.3.2.16.
Supervisory signal and switch for alarms, 3.2.4.9.,
3.2.6.7.
Supplemental energy dissipation
definitions and analysis, 4.1.8.21.
design considerations, 4.1.8.22.
Supply air
capacity, 9.33.5.1., 9.33.6.11.
crawl spaces, 9.32.3.7.
diffusers, 9.33.6.10., 9.33.6.11.
duct clearances, 3.6.5.6.
ducts, 1.4.1.2.[A], 6.3.2.7., 9.32.3.4., 9.32.3.8.,
9.33.6.5., 9.33.6.11.
fans, 9.32.3.4., 9.32.3.5., 9.32.3.6.
outlets, 9.32.3.5., 9.32.3.6., 9.33.6.10., 9.33.6.11.
systems, 9.32.3.4., 9.32.3.6., 9.33.5.
tempering, 6.3.2.8., 9.32.3.4., 9.32.3.5., 9.32.3.8.,
9.32.3.11.
ventilation, 9.32.3.4.
Supporting construction, fire-resistance rating,
3.1.7.5.
Supports
beams, 9.23.8.
cladding, 9.20.5., 9.23.10.5., 9.24.3.4.
combustible construction, 3.1.8.2., 9.10.9.8.
excavations, 4.2.5.3.
firewalls, 3.1.10.1., 4.1.5.17.
floors, 3.2.1.4., 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.8.3.,
9.30.1.3.
hearths, 9.22.5.2.
interior finishes, 9.23.10.5., 9.24.3.4.
joists, 9.23.14.7.
noncombustible construction, 9.10.8.4.
pipes, 6.7.1.1., 9.33.8.1.
walls, 9.23.9.8.
Surface temperature
of pipes, 6.7.1.4., 9.33.8.2.
of radiators, 6.7.1.3., 9.33.7.2.
Swinging doors, 3.8.3.6.
Symbols, 1.2.2.1., 1.4.2.1.[A]
Systems
characteristics, 1.2.2.1.[A]
storage, 1.2.2.2.[A]
used, 1.2.2.3.[A]
T
Tablet arms, 3.3.2.4.
Tape, sealing, 3.1.5.2., 3.6.5.3., 6.3.2.19., 9.33.6.3.
Telephones, 3.2.4.22., 3.2.6.7., 3.4.6.17., 3.8.3.20.
Temperature
indoor design, 5.2.1.2., 5.3.1.2., 5.5.1.2., 9.33.3.1.
outdoor design, 1.1.3.1., 5.2.1.1., 5.3.1.2., 5.5.1.2.,
6.2.1.2., 9.33.3.2., 9.33.5.1.
of pipes, 6.7.1.4., 9.33.8.2.
of radiators, 6.7.1.3., 9.33.7.2.
soils, 5.2.1.1., 5.2.1.3., 9.12.2.2., 9.16.2.2.
supply air, 9.33.6.11.
transfer calculations, 5.2.1.3.
Temperature controls
HVAC systems, 9.36.3.6.
indoor pools, 9.36.4.6.
service water heating systems, 9.36.4.5.
Tempering of makeup air, 6.3.2.8.,
Tents
clearance to flammable material, 3.1.6.4.
clearance to other structures, 3.1.6.3.
electrical systems, 3.1.6.7.
fire protection, 9.10.1.3.
fire safety restrictions, 3.1.6.2.
flame resistance, 3.1.6.5.
means of egress, 3.1.6.1.
roof coverings, 3.1.15.2.
Termites, protection against, 4.3.1.3., 9.3.2.9., 9.12.1.1.,
9.15.5.1.
Tests
building fire safety, 3.2.9.1.
fire-protection rating, 3.1.8.4., 9.10.3.1.
fire-resistance rating, 3.1.7.1., 9.10.3.1.
flame-spread rating, 3.1.12.1., 3.1.13.4., 6.9.1.1.,
9.10.3.2., 9.33.6.3., 9.33.6.4.
load, 4.1.1.5., 4.2.4.1., 9.23.14.11.
roof coverings, 3.1.15.1.
smoke developed classification, 3.1.12.1.
smoke movement in high buildings, 3.2.6.9.
sound transmission, 5.8.1.2., 9.11.1.2.
vapour permeance, 9.25.4.2.
Theatres, 1.4.1.2.[A], 3.3.2.14.
Thermal barriers
for foamed plastic, 9.10.17.10.
in noncombustible construction, 3.1.5.14., 3.1.5.15.
Thermal breaks, 5.9.2.4., 9.7.3.3.
Thermal bridging, 5.3.1.3., 9.25.1., 9.25.5.1.
Thermal insulation systems, 6.5.
Thermal resistance
building assemblies, 9.36.2.4., 9.36.2.6.
building assemblies below grade or in contact with
Index
Index British Columbia Building Code 2018
ground, 9.36.2.8.
location and installation of materials, 5.3.1.3.
materials in the building envelope, 9.25.5.1.
replacement options, 9.36.2.11.
requirements, 5.3.1., 9.25.1.
windows, doors and skylights, 9.36.2.7.
Thermal systems, solar, 9.36.3.11.
Ticket booths, 6.3.1.4.
Tile
clay, 9.23.4.5.
concrete, 9.23.4.5.
Tile, drainage, 9.14.3.
Tile, floor, 9.30.2.1., 9.30.2.2., 9.30.6.
Tile, roof
concrete, 5.9.1.1., 9.26.2.1.
eave protection, 9.26.5.1.
installation, 9.26.17.
Tile, wall
installation, 9.29.10.1.
moisture-resistant backing, 9.29.10.4.
Tires, storage, 3.3.6.5.
Top plates, walls, 9.23.5.4., 9.23.11.4.
Towers
earthquake loads and effects, 4.1.8.1.
wind loads, 4.1.7.11.
Toxic gases, storage, 3.3.6.3.
Trade shows, 3.1.2.3.
Traffic control, construction sites, 8.2.4.
Transformer vaults, 3.6.2.7., 9.10.1.3.
Transparent panels, 3.3.1.19., 3.4.1.8., 9.6.1.4., 9.7.2.1.
Transponder, for fire alarm, 3.2.7.10.
Travel distance
banks and mercantile facilities, 3.4.6.17.
to egress doorways, 3.3.1.5., 3.3.1.6.
to exit, 3.4.2.1., 3.4.2.3., 3.4.2.4., 9.9.8.2.
in fire compartments, 3.3.3.5.
measurement of, 9.9.8.1.
mezzanines, 9.9.8.6.
and number of required exits, 9.9.8.2.
rooms and suites, 9.9.7.4., 9.9.7.6.
to unlocked doors, 3.4.6.18.
Treads
dimensions, 3.3.1.16., 3.4.6.8., 9.8.4., 9.8.4.3.
finishes, 9.8.9.6.
nosings, 9.8.4.8.
rectangular, 9.8.3.1., 9.8.4.1., 9.8.4.2.
slip-resistance, 3.4.6.1., 9.8.9.6.
tapered, 3.3.1.16., 3.4.6.9., 9.8.3.1., 9.8.4.1., 9.8.4.3.,
9.8.4.4.
thickness, 9.8.9.5.
uniformity and tolerances, 9.8.4.4.
in winders, 9.8.4.6.
Treatment occupancy (see Care, treatment or
detention occupancy)
Trench, for piping of flammable liquids, 6.9.1.2.
Trim, for windows, doors and skylights, 9.7.6.2.
Trouble signals, 3.2.4.8., 3.2.4.9., 3.2.6.7.
Trusses
design, 9.4.1.1., 9.4.2.2., 9.23.14.11.
lumber grade, 9.3.2.1.
maximum deflections, 9.23.14.11.
snow loads, 9.4.2.2.
Tubing for pneumatic controls, 3.1.5.2., 3.6.4.3.
Turnstiles, 3.4.3.3., 9.9.5.4., 9.9.5.5.
Tying (see Anchorage)
U
Underground ducts, 6.3.2.12., 9.33.6.7.
Underground walkways, 3.1.13.9., 3.2.3.20., 3.2.7.3.,
9.9.12.3.
Underlay
fastening, 9.30.2.3.
for flooring, 9.30.2.
hardboard, 9.30.2.2.
installation, 9.26.6.2., 9.26.10.2., 9.30.2.3.
materials, 9.26.6.1., 9.30.2.2., 9.30.2.5.
material standards, 9.30.2.2.
nailing, 9.30.2.3.
OSB, 9.30.2.2.
particleboard, 9.30.2.2.
plywood, 9.30.2.2.
roofing, 9.26.6., 9.26.10.2.
beneath shakes, 9.26.10.2.
beneath shingles, 9.26.6.
stapling, 9.30.2.3.
thickness, 9.30.2.2.
Unit heaters, 1.4.1.2.[A]
Universal washrooms, 3.8.3.12.
Unprotected openings
(see also Openings)
area increase, 3.2.3.12.
definition, 1.4.1.2.[A]
in exposing building face, 3.2.3.7.
in exterior walls, 3.2.3.1.
in floors, 9.10.1.3.
maximum area, 9.10.14.4.
and spatial separation between buildings, 9.10.14., 9.10.15.
Index
British Columbia Building Code 2018 Index
unlimited, 3.2.3.10.
in wall exposed to another wall, 3.2.3.14.
Unsafe conditions, 1.1.1.1.[A], 1.4.1.2.[A]
Unstable liquids, 1.4.1.2.[A]
Unusual structures, 3.2.2.2.
Urinals, accessible design, 3.8.2.8., 3.8.3.14.
V
Vacuum cleaning systems
emergency shutdown, 3.2.4.13.
fire safety shutdown, 9.10.18.7.
penetrating fire separations, 3.1.9.5., 9.10.9.6.
suites served, 9.10.9.19.
Vapour
diffusion, 5.1.1.1., 5.2.1.2., 5.2.1.3., 5.5., 5.9.4.1.,
9.25.4.1., 9.25.5.1.
permeance, 5.5.1.2., 9.25.4.2., 9.25.5.1.
transfer, 5.1.1.1., 5.2.1.2., 5.2.1.3.
Vapour barriers
and dampproofing, 9.13.2.5.
definition, 1.4.1.2.[A]
in housing and small buildings, 9.25.4.
installation, 5.5.1.2., 9.23.2.2., 9.25.4.3.
in noncombustible construction, 3.1.5.2.
permeance, 5.5.1.2., 9.25.4.2.
products used, 9.25.4.3.
required resistance to vapour diffusion, 5.5.1.1.
requirements, 9.25.4.1.
standards for, 5.9.1.1., 9.25.4.2.
Vapour pressure, 5.5.1.1.
(see also Flammable liquids)
Vehicle guardrails, 4.1.5.15., 9.8.8.4.
Vehicular passageways, 3.1.13.2., 3.2.3.18.
Vehicular ramps, 3.2.8.2., 3.3.1.18., 9.8.8.4.
Vehicular traffic, construction sites, 8.2.3.1., 8.2.4.1.
Veneer
flashing, 5.6.2.1., 9.20.13.3.
masonry, 5.6.1.2., 9.20.6.4., 9.20.8.5., 9.20.9.5., 9.20.12.3.
Vent connectors, 1.4.1.2.[A]
Ventilating systems (see Heating, ventilating
and air-conditioning (HVAC) systems and
equipment)
Ventilation
of air contaminants, 6.3.1.6.
attic or roof spaces, 6.3.1.2., 9.19.1.
capacity, 9.32.2.3., 9.32.3.3.
crawl spaces, 6.3.1.2., 9.18.3., 9.18.3.1., 9.18.3.2.
definition, 1.4.1.2.[A]
direct-vent, 9.32.3.8.
dwelling units, 6.3.1.1., 9.32.
electrical equipment vaults, 3.6.2.7.
exhaust, 3.3.1.20., 9.10.9.18., 9.32.3.6., 9.32.3.13.
exhaust ducts and outlets, 6.3.2.10.
garages, 3.3.5.4.
housing and small buildings, 9.32.
mechanical, 6.3.1.1., 6.3.1.4. - 6.9.1.2., 9.32.2.3.,
9.32.3., 9.32.3.3. - 9.32.3.6.
natural, 6.3.1.3., 9.32.2.2.
outlets, 9.32.3.5., 9.32.3.6.
requirements, 6.2.2., 6.3.1.1., 9.32.1.2., 9.32.2.1.,
9.32.3.1.
residential, 6.3.1.1.
restaurants, 6.3.1.7.
secondary suites, 9.32.3.4., 9.37.2.17.
storage garages, 3.3.5.7., 6.3.1.4., 9.32.1.1.
windows for, 9.32.2.2.
Venting
air space in building envelopes, 9.25.5.1., 9.27.2.2.
attic or roof spaces, 5.3.1.2., 6.3.1.2., 9.19.1.
chimneys, 9.21., 9.33.10.1.
combustion products, 6.3.3.1., 9.32.3.8., 9.33.10.1.
crawl spaces, 6.3.1.2., 9.18.3., 9.18.3.1., 9.18.3.2.
explosion relief devices, 3.3.1.20.
firefighting, 3.2.8.7.
firefighting in high buildings, 3.2.6.6., 3.2.6.9.
heating appliances, 9.21., 9.33.5.2., 9.33.5.3.,
9.33.10.1.
laundry-drying equipment, 9.32.1.3.
mansard or gambrel roofs, 9.19.1.4.
soffits, 9.19.1.2., 9.19.1.3., 9.25.2.4.
Vents
area, 9.19.1.2.
gas, 9.33.10.1.
installation, 9.19.1.2.
in stair shafts, 3.2.6.2.
standard for, 9.19.1.2.
Vertical service spaces
application of Code, 3.6.1.1., 3.6.3.1.
combustible piping in, 3.1.9.5.
definition, 1.4.1.2.[A]
for dumbwaiters, 3.5.3.2.
elevator machinery, 3.5.3.3.
exhaust ducts, 3.6.3.4., 9.10.9.18.
fire dampers, 9.10.13.13.
fire protection, 9.10.1.3.
fire separations, 3.6.3.1.
flame-spread rating, 3.1.13.2.
Index
Index British Columbia Building Code 2018
penetrating floor assemblies, 3.2.8.1.
Vestibules
(see also Lobbies)
access to storage garages, 3.3.5.7.
barrier-free doors, 3.8.3.6.
and closure devices, 3.1.8.19.
elevators for use by firefighters, 3.2.6.5.
garages, 3.3.5.4.
high buildings, 3.1.13.7.
horizontal exits, 3.4.6.10.
interconnected floor space, 3.2.8.4.
Vibrations
combustible isolation connector, 3.6.5.2., 6.3.2.18.
floors, 9.23.4.1., 9.23.4.2.
limit states design, 4.1.3.6.
Visual disability, 3.3.1.9.
Visual signal devices, 3.2.4.19.
Voice communication systems
central alarm and control facility, 3.2.6.7.
emergency power supply, 3.2.7.8.
high buildings, 3.2.6.8.
requirements, 3.2.4.22.
speakers, 3.2.4.22.
use of alarm circuitry, 3.2.4.18.
W
Waferboard
as cladding, 5.9.1.1., 9.27.2.4., 9.27.3.6., 9.27.5.,
9.27.10.
fire blocks, 9.10.16.3.
fire protection of soffits, 9.10.12.4.
fire stops, 3.1.11.7.
as interior finish, 9.29.9.
material, 9.3.2.4.
material standard, 5.9.1.1., 9.23.15.2., 9.23.16.2.,
9.23.17.2., 9.27.10.1., 9.29.9.1., 9.30.2.2.
as roof sheathing, 9.3.2.4., 9.23.3.5., 9.23.16.
as siding, 9.27.3.6., 9.27.5., 9.27.10.
as subflooring, 9.3.2.4., 9.23.3.5., 9.23.15.2.,
9.23.15.5.
thickness, 9.3.2.7.
as underlay, 9.30.2.
as wall sheathing, 9.3.2.4., 9.23.3.5., 9.23.10.2.,
9.23.17.2., 9.23.17.5.
Walk-in coolers/freezers, 3.1.4.2., 3.1.5.7., 9.10.17.10.
Walks, moving, 3.2.8.2., 3.8.2.3., 3.8.2.4., 9.8.1.4.
Walkways
accessible path of travel, 3.8.3.3.
between buildings, 3.2.3.19.
construction camps, 9.10.21.4.
construction sites, 8.2.1.1.
definition, 1.4.1.2.[A]
exterior, 3.8.3.3., 9.9.4.2., 9.9.9.3., 9.10.8.8., 9.10.17.4.
fire protection, 9.10.1.3.
smoke detectors, 3.2.4.11.
underground, 3.1.13.9., 3.2.3.20., 3.2.7.3., 9.9.12.3.
Wall membranes, 9.10.5.
Wall panels
braced (see Braced wall panels)
factory-assembled, 3.1.5.7.
Wall plates, 9.23.3.4., 9.23.11.
Walls
(see also Walls, exterior)
air barrier systems, 9.25.3.
anchorage, 9.20.11., 9.23.3.4., 9.35.4.3.
area, calculating, 9.36.2.3.
bracing, 9.23.10.2., 9.23.13.
in carports, 9.35.4.1., 9.35.4.3.
cladding, 9.27.
continuity of insulation, 9.36.2.5.
exposed to adjoining roof, 3.2.3.15., 9.10.12.2.
fire blocks in, 9.10.16.2.
fire-resistance rating, 3.2.3.7., 3.2.3.11., 9.10.8.3.,
9.10.14.5., 9.10.15.5.
firewalls (see Firewalls)
foamed plastics in, 9.10.17.10.
foundations, 4.2., 9.15.4.
framing, 9.23.10., 9.24.
garages, 9.35.4.1.
as guards, 4.1.5.16.
in health facilities, 3.3.3.5.
height, 9.20.6.
intersecting, anchorage, 9.20.11.
lateral support, 9.20.10., 9.23.10.2.
loadbearing, 3.2.1.4., 9.10.8.3., 9.23.9.8., 9.23.10.1.,
9.23.10.2., 9.23.10.6., 9.23.12.2., 9.23.12.3., 9.24.1.1.
masonry, 5.6.1.2., 9.20., 9.25.3.4.
masonry veneer, 5.6.1.2., 9.20.6.4.
non-loadbearing, 9.23.9.8., 9.23.10.1., 9.23.10.6.,
9.23.12.1., 9.24.
openings in loadbearing, 9.23.10.6., 9.23.12.2.,
9.23.12.3.
openings in non-loadbearing, 9.23.10.6., 9.23.12.1.,
9.24.2.4., 9.24.3.5., 9.24.3.7.
in public corridors, 9.10.17.5.
recesses, 9.20.7.
retaining, 9.3.2.9., 9.4.4.5., 9.4.4.6.
Index
British Columbia Building Code 2018 Index
sheathing, 9.23.13., 9.23.17., 9.27.3.4., 9.27.3.5.
steel stud, 9.24.
support on framed floors, 9.23.9.8.
supports, 9.23.9.8.
thermal insulation, 9.25.1.1.
thickness, 9.20.6.
wind loads, 4.1.7.5., 4.1.7.6.
Walls, exterior
in combustible construction, 3.1.4.8.
continuity of insulation, 9.36.2.5.
enclosing attic or roof space, 3.2.3.3.
exposed to another wall, 3.2.3.14., 9.10.12.3.
fire-resistance rating, 3.1.7.2., 3.1.7.3., 3.2.3.7.,
3.2.3.11., 9.10.3.1., 9.10.3.3., 9.10.14.5., 9.10.15.5.
at firewall, 3.1.10.6.
in noncombustible construction, 3.1.5.5., 3.1.5.6.
restrictions on combustible projections, 3.2.3.6.,
9.10.14.5., 9.10.15.5.
thickness, 9.20.6.1.
Walls, interior
airtightness, 9.36.2.10.
finish, 9.29.
not fire separations, 9.10.12.3.
thickness, 9.20.6.3.
Wall studs (see Studs, steel; Studs,wood)
Warehouses
door swing, 3.3.1.11.
loads on floor or roof, 4.1.5.3.
self-storage, 3.3.5.9., 9.9.6.4.
Warm air outlets, 9.33.6.10., 9.33.6.11.
Warning lights, construction sites, 8.2.3.5.
Wash fountains, circular, 3.7.2.3.
Washrooms
(see also Bathrooms)
accessible, 3.8.2.8., 3.8.3.9., 3.8.3.11., 3.8.3.15.
emergency lighting, 3.2.7.3.
floor drains, 3.7.2.7.
requirements, 3.7.2.2.
signage, 3.8.3.9.
surface protection, 3.7.2.6.
universal, 3.8.3.12.
Waste material
chutes, 8.2.5.4.
enclosures, 8.2.5.3.
removal, 8.2.5.2.
Water
(see also Groundwater)
accumulation, 5.6.2.2., 5.7.1.1.
drainage, 5.6.2.2., 9.14.
drainage disposal, 9.14.5.
in excavations, 9.12.1.2.
flooring resistant to, 9.30.1.2.
ingress, 5.7.1.1.
protection against, application of Code, 9.13.1.1.
protection against, in exterior insulation finish
systems, 5.9.4.1.
protection against, in fenestration, 5.9.3.5.
protection against hydrostatic pressure, 5.7.2.
protection from groundwater, 5.7.3.
required protection against, 5.7.1.2.
surface, 5.7., 5.7.1.1.
Water closets
bathtubs, 3.7.2.9.
doorways, 9.5.5.2.
in dwelling units, 9.31.4.1.
floor drains, 3.7.2.7.
grab bars, 3.7.2.8.
for persons with disabilities, 3.8.3.13.
requirements, 3.7.2.2.
stalls, 3.8.3.11.
surface protection, 3.7.2.6.
Waterflow detecting devices, 3.2.4.4., 3.2.4.7., 3.2.4.15.,
3.2.5.14., 3.2.6.7.
Water heaters, solar, 9.36.4.3.
Waterproof flooring, 9.30.1.2.
Waterproofing
floors-on-ground, 9.13.3.1., 9.13.3.5.
installation, 5.6.1.2., 9.13.3.4.
installation standards, 9.26.15.1.
material standards, 5.9.1.1., 9.13.3.2., 9.26.2.1.
preparation of surface, 9.13.3.3.
protection from groundwater, 5.7.3.3.
requirement for, 9.13.3.1.
roofs, 5.6.1.2., 9.13.3.1., 9.26.2.1.
walls, 9.13.3.1., 9.13.3.3., 9.13.3.4.
Waterproof interior wall finish, 9.29.2.
Water supply
for firefighting, 3.2.5.7., 3.2.5.9., 3.2.7.9.
hot water, 9.31.4.2.
potable water, 9.31.3.
Water supply valves, 3.2.4.9.
Water systems
dwelling units, 9.31.3.
potable water, 9.31.3.1.
Water treatment, evaporative cooling systems,
6.3.2.15.
Weep holes, 9.20.13.5., 9.20.13.6., 9.20.13.8.
Welding operations room, 3.3.1.25.
Index
Index British Columbia Building Code 2018
Wells
dry, 9.14.5.3.
water supply, 9.14.6.2.
Wheelchair spaces, and path of travel, 3.8.2.3.,
3.8.3.21.
Wheelchair turning space, universal washrooms,
3.8.3.12.
Winders, 9.8.3.1., 9.8.4.1., 9.8.4.4., 9.8.4.6.
Wind load
and air barrier systems, 9.25.3.2.
anchorage of building frames, 9.23.6.1.
bracing to resist, 9.23.13.
calculation of, 4.1.7., 5.2.1.3., 5.2.2.2.
dynamic effects, 4.1.7.2.
dynamic procedure, 4.1.7.8.
environmental separation, 5.1.4.1.
exterior ornamentations, equipment and
appendages, 4.1.7.11.
external pressure coefficients, 4.1.7.5.
external pressure coefficients, low buildings,
4.1.7.6.
fasteners for sheathing or subflooring, 9.23.3.5.
full and partial, 4.1.7.9.
interior walls and partitions, 4.1.7.10.
internal pressure coefficient, 4.1.7.7.
pressure differences due to, 4.1.7.10., 5.4.1.2.
roof sheathing, 9.23.16.1.
specified, 4.1.7.1.
static procedure, 4.1.7.3.
and structural design, 4.1.7.
structural strength, 9.4.1.1., 9.6.1.3.
topographic factor, 4.1.7.4., 9.6.1.3.
wind tunnel procedure, 4.1.7.12.
Windows
(see also Closures; Fenestration; Glass; Skylights)
access for firefighting, 9.10.20.1.
airtightness, 5.9.1.1., 5.9.2.3., 9.7.4., 9.36.2.9., 9.36.2.10.
barriers or railings with, 3.3.1.19.
in bedrooms, 9.9.10.1.
caulking and sealing, 9.7.4., 9.20.13.11., 9.27.4.
as closures, 3.1.8.5.
dimensions, 9.32.2.2.
in exits, 9.9.4.5.
in exposing building faces, 9.10.14.4., 9.10.15.4.
flashing, 9.20.13.3., 9.20.13.4., 9.20.13.12., 9.27.3.8.
glass thickness, 9.6.1.3.
for housing and small buildings, 9.7.
installation, 9.7.6.
manufactured and pre-assembled, 9.7.4.
as means of egress, 9.7.2.2.
for natural ventilation, 9.32.2.2.
in noncombustible construction, 3.1.5.4.
not a means of egress, 9.9.2.3.
opening into window wells, 9.9.10.1.
openings, 9.8.8.1., 9.9.10.1.
protection of, 3.3.4.8.
protection in public areas, 9.8.8.1.
protection in residential occupancy, 9.8.8.1.
requirements, 9.7.2.2.
resistance to forced entry, 9.7.5.3.
sills, 9.20.13.12., 9.27.3.8.
standard for, 5.9.1.1., 5.9.2.2., 9.7.4.
thermal breaks, 5.9.2.4., 9.7.3.3.
thermal resistance calculation, 9.36.2.11.
thermal transmittance (U-value), 9.7.3.3.
unobstructed opening area, 9.9.10.1., 9.32.2.2.
watertightness, 5.9.1.1., 5.9.2.3., 9.7.4.
wind load resistance, 5.2.2.2., 9.7.4.
Window walls (see Fenestration)
Window wells, 9.9.10.1., 9.14.6.3.
Wind tunnel procedure, 4.1.7.12.
Wired glass
area limits, 3.1.8.18.
area limits waived, 3.1.8.19.
as closure, 9.10.13.5.
in exits, 3.2.3.13., 9.9.4.3.
in fire separations, 3.1.8.16.
in guards, 9.8.8.7.
not to be used as closures, 3.2.3.5.
temperature rise limits waived, 3.1.8.19.
in transparent panels and doors, 3.3.1.19.
in unprotected openings, 3.2.3.12., 9.10.14.4.
uses, 9.6.1.4.
in windows, doors and skylights, 5.9.1.1., 5.9.2.1.
Wires and cables
in combustible construction, 3.1.4.3.
electrical, 3.2.6.5., 9.34., 9.34.1.5.
in fire separations, 9.10.9.6.
in noncombustible construction, 3.1.5.21.
penetrating fire separations, 3.1.9.3.
in plenums, 3.6.4.3.
protection of electrical conductors, 3.2.7.10.
storage, 3.3.6.2.
Wood
bracing, 9.23.13.
cant strips, 9.26.4.6., 9.26.4.7., 9.26.11.10.
columns, 9.10.14.5., 9.10.15.5., 9.17.4., 9.35.4.2.
design and construction, 9.23.
Index
British Columbia Building Code 2018 Index
door frames, 9.10.13.3.
doors, 9.7.5.2.
fire-resistance rating, 9.10.6.2.
fire-retardant-treated (see Fire-retardant-treated
wood)
floor beams, 9.23.8.1.
floor joists, 9.23.9.
flooring, 9.30.3., 9.30.4.
floors-on-ground, 9.16.5.
floor supports, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.8.3.,
9.30.1.3.
foundations, 4.2.3.1., 4.2.3.2., 9.15.1.1., 9.15.2.4.
in heavy timber construction, 3.1.4.7.
in noncombustible construction, 3.1.5.2., 3.1.5.3.,
3.1.5.5., 3.1.5.8., 3.1.5.10.
preservative treatment, 4.2.3.2., 9.8.9.3., 9.23.2.2.,
9.23.2.3.
roofs, 3.1.14.1., 9.23.4.1., 9.23.4.2., 9.23.4.5., 9.23.16.
shingles and shakes, 9.26.2.1., 9.26.2.3., 9.26.3.1.,
9.26.9., 9.26.10., 9.27.7.
siding, 9.27.6., 9.27.7., 9.27.8., 9.27.9., 9.27.10.
stairs, 9.8.9.3., 9.8.9.4.
structural design basis, 4.3.1.
Wood blocking
cladding, 9.23.10.5., 9.27.5.2.
doors, 9.7.5.2.
with handrails, 9.8.7.7.
interior finishing materials, 9.23.10.5.
joists, 9.23.9.3., 9.23.9.4., 9.23.14.9.
nailing, 9.23.3.4.
in noncombustible construction, 3.1.5.2.
rafters and joists, 9.23.14.7.
roof edges, 9.23.16.6., 9.23.16.7.
subflooring, 9.23.15.3.
walls, 9.23.9.8., 9.23.10.2.
Wood-burning appliances
chimney liners, 9.21.3.9., 9.22.2.3.
chimneys and flues, 6.3.3.2., 6.3.3.3., 9.21.1.1.,
9.21.2.1., 9.21.2.2., 9.33.10.2.
ducts serving, 3.6.5.8., 9.33.6.13.
factory-built fireplaces, 9.22.1.4., 9.22.8.1.
hearth-mounted stoves, 9.22.10.
inserts, 9.22.10.
installation, 3.6.2.1.
installation standard, 6.2.1.5., 9.22.10.2., 9.31.6.2.
masonry fireplaces, 9.22.
product standards, 9.22.2.3., 9.22.8.1., 9.22.10.1.,
9.33.5.3.
protection against depressurization, 9.32.3.8.
venting, 6.3.3.1., 9.33.10.1.
Wood-frame construction
alternative structural components, 9.23.1.1.
beams to support floors, 9.23.8.
bracing for earthquake and wind loads, 9.23.13.
fasteners, 9.23.3.
floor joists, 9.23.9.
framing over openings, 9.23.12.
housing and small buildings, 9.23.
maximum spans, 9.23.4.
notching and drilling, 9.23.5.
roof and ceiling framing, 9.23.14.
roof sheathing, 9.23.16.
sill plates, 9.23.7.
subflooring, 9.23.15.
wall plates, 9.23.11.
wall sheathing, 9.23.17.
wall studs, 9.23.10.
Wood products
dimensions, 9.3.2.6., 9.3.2.7.
for housing and small buildings, 9.3.2.
preservative treatment, 9.3.2.9.
protection against moisture, 9.3.2.9.
undersized, 9.3.2.8.
Y
Yard, as access for firefighters, 9.10.20.3.
Index
British Columbia Building Code 2018 Index
door frames, 9.10.13.3.
doors, 9.7.5.2.
fire-resistance rating, 9.10.6.2.
fire-retardant-treated (see Fire-retardant-treated
wood)
floor beams, 9.23.8.1.
floor joists, 9.23.9.
flooring, 9.30.3., 9.30.4.
floors-on-ground, 9.16.5.
floor supports, 9.23.4.1., 9.23.4.2., 9.23.4.4., 9.23.8.3.,
9.30.1.3.
foundations, 4.2.3.1., 4.2.3.2., 9.15.1.1., 9.15.2.4.
in heavy timber construction, 3.1.4.7.
in noncombustible construction, 3.1.5.2., 3.1.5.3.,
3.1.5.5., 3.1.5.8., 3.1.5.10.
preservative treatment, 4.2.3.2., 9.8.9.3., 9.23.2.2.,
9.23.2.3.
roofs, 3.1.14.1., 9.23.4.1., 9.23.4.2., 9.23.4.5., 9.23.16.
shingles and shakes, 9.26.2.1., 9.26.2.3., 9.26.3.1.,
9.26.9., 9.26.10., 9.27.7.
siding, 9.27.6., 9.27.7., 9.27.8., 9.27.9., 9.27.10.
stairs, 9.8.9.3., 9.8.9.4.
structural design basis, 4.3.1.
Wood blocking
cladding, 9.23.10.5., 9.27.5.2.
doors, 9.7.5.2.
with handrails, 9.8.7.7.
interior finishing materials, 9.23.10.5.
joists, 9.23.9.3., 9.23.9.4., 9.23.14.9.
nailing, 9.23.3.4.
in noncombustible construction, 3.1.5.2.
rafters and joists, 9.23.14.7.
roof edges, 9.23.16.6., 9.23.16.7.
subflooring, 9.23.15.3.
walls, 9.23.9.8., 9.23.10.2.
Wood-burning appliances
chimney liners, 9.21.3.9., 9.22.2.3.
chimneys and flues, 6.3.3.2., 6.3.3.3., 9.21.1.1.,
9.21.2.1., 9.21.2.2., 9.33.10.2.
ducts serving, 3.6.5.8., 9.33.6.13.
factory-built fireplaces, 9.22.1.4., 9.22.8.1.
hearth-mounted stoves, 9.22.10.
inserts, 9.22.10.
installation, 3.6.2.1.
installation standard, 6.2.1.5., 9.22.10.2., 9.31.6.2.
masonry fireplaces, 9.22.
product standards, 9.22.2.3., 9.22.8.1., 9.22.10.1.,
9.33.5.3.
protection against depressurization, 9.32.3.8.
venting, 6.3.3.1., 9.33.10.1.
Wood-frame construction
alternative structural components, 9.23.1.1.
beams to support floors, 9.23.8.
bracing for earthquake and wind loads, 9.23.13.
fasteners, 9.23.3.
floor joists, 9.23.9.
framing over openings, 9.23.12.
housing and small buildings, 9.23.
maximum spans, 9.23.4.
notching and drilling, 9.23.5.
roof and ceiling framing, 9.23.14.
roof sheathing, 9.23.16.
sill plates, 9.23.7.
subflooring, 9.23.15.
wall plates, 9.23.11.
wall sheathing, 9.23.17.
wall studs, 9.23.10.
Wood products
dimensions, 9.3.2.6., 9.3.2.7.
for housing and small buildings, 9.3.2.
preservative treatment, 9.3.2.9.
protection against moisture, 9.3.2.9.
undersized, 9.3.2.8.
Y
Yard, as access for firefighters, 9.10.20.3.