The Ontario Building Code | Incorrect Placement of Shallow Foundations
4.2.6.3. Incorrect Placement of Shallow foundations
(1) Where a shallow foundation unit has not been placed or located as indicated on the drawings,
(a) the error shall be corrected, or
(b) the design of the foundation unit shall be recalculated for the altered conditions by the designer.