3.2.3.13. Protection of Exit Facilities

(1) Except as required by Sentence (3) and as permitted by Sentence 3.4.4.3.(1), if the plane of an exterior wall of an exitenclosure forms an angle less than 135° with the plane of an exterior wall of the building it serves, and an opening in the exterior wall of the exit enclosure could be exposed to fire from an opening in the exterior wall of the building, the opening in either the exterior wall of the exitor the exterior wall of the building shall be protected in conformance with the requirements of Sentence (4) where the opening in the exterior wall of the building is within 3 m horizontally and,

(a) less than 10 m below an opening in the exterior wall of the exit, or

(b) less than 2 m above an opening in the exterior wall of the exit.

(2) If an unenclosed exterior exit stair or ramp could be exposed to fire from an opening in the exterior wall of the building it serves, the opening in the exterior wall of the building shall be protected in conformance with the requirements of Sentence (4) where the opening in the exterior wall of the building is within 3 m horizontally and,

(a) less than 10 m below the exit stair or ramp, or

(b) less than 5 m above the exit stair or ramp.

(3) Except as permitted by Sentence 3.4.4.3.(1), if an exterior exit door in one fire compartmentis within 3 m horizontally of an opening in another fire compartment and the exterior walls of these fire compartments intersect at an exterior angle of less than 135°, the opening shall be protected in conformance with the requirements of Sentence (4).

(4) The opening protection referred to in Sentences (1) to (3) shall consist of,

(a) glass block conforming to the requirements of Article 3.1.8.14.,

(b) a wired glass assembly conforming to MMAH Supplementary Standard SB-2, "Fire Performance Ratings", or

(c) a closureconforming to the requirements of Subsection 3.1.8. and Articles 3.2.3.1. and 3.2.3.14.