The Ontario Building Code | Public and Service Areas

9.34.2.7. Public and service Areas

(1) Every public or service area in buildings, including a recreational camp and a camp for housing of workers, shall have lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting outlets with fixtures controlled by a wall switch or panel to illuminate such areas.

(2) When provided by incandescent lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting, illumination required in Sentence (1) shall conform to Table 9.34.2.7.

(3) When other types of lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting are used, illumination equivalent to that shown in Table 9.34.2.7. shall be provided.

Table 9.34.2.7.
lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting for Public Areas

Forming Part of Sentences 9.34.2.7.(2) and (3)

Item

Column 1

Room or Space

Column 2

Minimum Illumination, lx

Column 3

Minimum lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting Power Density, W/m2 of floor area (incandescent lighting="http://thehandyforce.com/electrical/" title ="East York Electrician">lighting)

1.

Storage rooms

50

5

2.

service rooms and laundry areas

200

20

3.

garages

50

5

4.

Public water closet rooms

100

10

5.

service hallways and stairways

50

5

6.

Recreation rooms

100

10

7.

Hallways, corridors, stairways and sleeping areas in recreational camps and camps for housing of workers

100

10

8.

Kitchen in recreational camps and camps for housing of workers

500

50

9.

All other rooms in recreational camps and camps for housing of workers

250

25