The Ontario Building Code | Nailing

9.30.3.3. Nailing

(1) When nails are used, wood strip flooring="http://thehandyforce.com/flooring/" title ="Handyman flooring install Toronto">flooring shall be toe nailed or face nailed with at least one nail per strip at the spacings shown in Table 9.30.3.3., except that face nailed strips of more than 25 mm in width shall have at least two nails per strip.

(2) Face nails shall be countersunk.

Table 9.30.3.3.
Nailing of wood Strip flooring="http://thehandyforce.com/flooring/" title ="Handyman flooring install Toronto">flooring

Forming Part of Sentence 9.30.3.3.(1)

Item

Column 1

Finish floor Thickness, mm

Column 2

Minimum Length of flooring="http://thehandyforce.com/flooring/" title ="Handyman flooring install Toronto">flooring Nails, mm

Column 3

Maximum Spacing of flooring="http://thehandyforce.com/flooring/" title ="Handyman flooring install Toronto">flooring Nails, mm

1.

7.9

38(1)

200

2.

11.1

51

300

3.

19.0

57

400

4.

25.4

63

400

5.

31.7

70

600

6.

38.1

83

600

Notes to Table 9.30.3.3.:

(1) See Article 9.30.3.4.