The Ontario Building Code | Clearances for a Class 4 or 5 Sewage System

8.2.1.6. Clearances for a Class 4 or 5 Sewage System

(1) Except as provided in Sentences 8.2.1.4.(1) and (2), a treatment unit shall not be located closer than the minimum horizontal distances set out in Table 8.2.1.6.A.

Table 8.2.1.6.A.
Minimum Clearances for Treatment Units

Forming Part of Sentence 8.2.1.6.(1)

Item

Column 1

Object

Column 2

Minimum Clearance, m

1.

Structure

1.5

2.

Well

15

3.

Lake

15

4.

Pond

15

5.

Reservoir

15

6.

River

15

7.

Spring

15

8.

Stream

15

9.

Property Line

3

(2) Except as provided in Sentences 8.2.1.4.(1) and (2), a distribution pipe shall not be located closer than the minimum horizontal distances set out in Table 8.2.1.6.B. and these distances shall be increased when required by Sentence 8.7.4.2.(11).

Note: On January 1, 2018, Sentence 8.2.1.6.(2) of Division B of the Regulation is amended by striking out "a distribution pipe" and substituting "the centreline of a distribution pipe or leaching chamber". (See: O. Reg. 139/17, s. 57 (1))

Table 8.2.1.6.B.
Minimum Clearances for Distribution Piping

Note: On January 1, 2018, the heading to Table 8.2.1.6.B. of Division B of the Regulation is amended by adding "and Leaching Chambers" after "Distribution Piping". (See: O. Reg. 139/17, s. 57 (2))

Forming Part of Sentence 8.2.1.6.(2)

Item

Column 1

Object

Column 2

Minimum Clearance, m

1.

Structure

5

2.

Well with a watertight casing to a depth of at least 6 m

15

3.

Any other well

30

4.

Lake

15

5.

Pond

15

6.

Reservoir

15

7.

River

15

8.

Spring not used as a source of potable water

15

9.

Stream

15

10.

Property Line

3

(3) Except as provided in Sentences 8.2.1.4.(1) and (2), a holding tank shall not be located closer than the minimum horizontal distances set out in Table 8.2.1.6.C.

Table 8.2.1.6.C.
Minimum Clearances for Holding Tanks

Forming Part of Sentence 8.2.1.6.(3)

Item

Column 1

Object

Column 2

Minimum Clearance, m

1.

Structure

1.5

2.

Well with a watertight casing to a depth of at least 6 m

15

3.

Any other well

15

4.

Spring

15

5.

Property Line

3

8.2.2. Treatment and Holding Tanks