The Ontario Building Code | Clearance Distances for Class 1, 2 and 3 Sewage Systems

8.2.1.5. Clearance Distances for Class 1, 2 and 3 Sewage Systems

(1) Except as provided in Sentences 8.2.1.4.(1) and (2), no Class 1, 2 or 3 sewage system shall have a horizontal distance of less than that permitted by Table 8.2.1.5.

Table 8.2.1.5.
Clearance Distances for Class 1, 2 and 3 Sewage Systems

Forming Part of Sentence 8.2.1.5.(1)

Item

Column 1

Sewage System

Column 2

Minimum horizontal distance in metres from a well with watertight casing to a depth of at least 6 m

Column 3

Minimum horizontal distance in metres from a spring used as a source of potable water or well other than a well with a watertight casing to a depth of at least 6 m

Column 4

Minimum horizontal distance in metres from a lake, river, pond, stream, reservoir, or a spring not used as a source of potable water

Column 5

Minimum horizontal distance in metres from a property line

1.

Earth Pit Privy

15

30

15

3

2.

Privy Vault

10

15

10

3

Pail Privy

3.

Greywater System

10

15

15

3

4.

Cesspool

30

60

15

3