7.5.8.4. vent Stacks, or Stack vents

(1) A vent stack, or stack vent shall be sized in accordance with Table 7.5.8.4. based on,

(a) the length of the vent stack or stack vent, and

(b) the total hydraulic load that is drained to the lowest section of soil or waste stack or stacks served by the vent pipe, plus any additional vent loads connected to the vent stack or stack vent.

Table 7.5.8.4.
Size and Developed Length of Stack vents and vent Stacks

Forming Part of Sentence 7.5.8.4.(1)

Column 1

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Column 8

Column 9

Column 10

Column 11

Column 12

Column 13

Size of soil or Waste Stack, in.

Total Hydraulic Load Being vented, fixture units

water OccupiedArea

Size of Stack vent or vent Stack, in.

1 ½

2

3

4

5

6

8

10

12

Maximum Length of Stack vent or vent Stack, m(1)(2)

2

0.29

9

NL

NL

NL

NL

NL

NL

NL

NL

NL

8

0.25

15

46

NL

NL

NL

NL

NL

NL

NL

NL

2

12

0.25

9

23

61

NL

NL

NL

NL

NL

NL

NL

24

.29

8

15

46

NL

NL

NL

NL

NL

NL

NL

3

10

0.15

NP

13

46

317

NL

NL

NL

NL

NL

NL

21

.20

NP

10

33.5

247

NL

NL

NL

NL

NL

NL

53

.25

NP

8

28.5

207

NL

NL

NL

NL

NL

NL

102

.29

NP

7.5

26

189

NL

NL

NL

NL

NL

NL

4

43

0.15

NP

NP

10.5

76

299

NL

NL

NL

NL

NL

140

.20

NP

NP

8

61

229

NL

NL

NL

NL

NL

320

.25

NP

NP

7

52

195

NL

NL

NL

NL

NL

540

.29

NP

NP

6.5

46

177

NL

NL

NL

NL

NL

5

190

0.15

NP

NP

NP

25

97.5

302

NL

NL

NL

NL

490

.20

NP

NP

NP

19

76

232

NL

NL

NL

NL

940

.25

NP

NP

NP

16

64

204

NL

NL

NL

NL

1 400

.29

NP

NP

NP

15

58

180

NL

NL

NL

NL

6

500

0.15

NP

NP

NP

10

39.5

122

305

NL

NL

NL

1 100

.20

NP

NP

NP

8

30.5

94.5

238

NL

NL

NL

2 000

.25

NP

NP

NP

6.5

25.5

79

201

NL

NL

NL

2 900

.29

NP

NP

NP

6

23.5

73

183

NL

NL

NL

8

1 800

0.15

NP

NP

NP

NP

9.5

29

73

287

NL

NL

3 400

.20

NP

NP

NP

NP

7

22

58

219.5

NL

NL

5 600

.25

NP

NP

NP

NP

6

19

49

186

NL

NL

7 600

.29

NP

NP

NP

NP

5.5

17

43

170.5

NL

NL

10

4 000

0.15

NP

NP

NP

NP

NP

9.5

24

94.5

292.5

NL

7 200

.20

NP

NP

NP

NP

NP

7

18

73

225.5

NL

11 000

.25

NP

NP

NP

NP

NP

6

15.5

61

192

NL

15 000

.29

NP

NP

NP

NP

NP

5.5

14

55

174

NL

12

7 300

0.15

NP

NP

NP

NP

NP

NP

9.5

36.5

116

287

13 000

.20

NP

NP

NP

NP

NP

NP

7

28.5

91

219.5

20 000

.25

NP

NP

NP

NP

NP

NP

6

24

76

186

26 000

.29

NP

NP

NP

NP

NP

NP

5.5

22

70

152

15

15 000

0.15

NP

NP

NP

NP

NP

NP

NP

12

39.5

94.5

25 000

.20

NP

NP

NP

NP

NP

NP

NP

9.5

29

73

38 000

.25

NP

NP

NP

NP

NP

NP

NP

8

24.5

62

50 000

.29

NP

NP

NP

NP

NP

NP

NP

7

22.5

55

Notes to Table 7.5.8.4.:

(1)NL means not limited.

(2)NP means not permitted.

(2) For the purposes of Table 7.5.8.4., the length of a stack vent or vent stack shall be its developed length from its lower end to open air.

(3) The minimum size of vent stack or stack vent shall be one-half the size of the soilor waste stack at its base.

(4) A stack vent serving a wet vent stack that is over 4 storeyshigh shall extend the full size of the wet vent to open air.

(5) Every sanitary building drain shall be provided with at least one vent that is not less than 3 in. in size.